JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Parkinson, A J
Right arrow Articles by Johnson, C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Parkinson, A J
Right arrow Articles by Johnson, C
J Clin Microbiol. 1992 February; 30(2): 318-322

Quantitation of pneumococcal C polysaccharide in sputum samples from patients with presumptive pneumococcal pneumonia by enzyme immunoassay.

A J Parkinson, M E Rabiego, C Sepulveda, M Davidson and C Johnson

Arctic Investigations Program, Centers for Disease Control, Anchorage Alaska 99501.

ABSTRACT

Although the Gram stain and culture of expectorated sputum are considered standard methods for the diagnosis of presumptive pneumococcal pneumonia, these methods remain relatively insensitive and nonspecific. We developed an enzyme immunoassay (EIA) for the quantitation of pneumococcal C polysaccharide (PnC) in the sputum of patients with presumptive pneumococcal pneumonia. Of 34 patient sputum samples collected within 24 h of the first radiographic report of pneumonia, 12 grew Streptococcus pneumoniae on culture. By using a cutoff point of 0.5 micrograms of PnC per ml of sputum, all 12 specimens were positive (sensitivity, 100%) by EIA. PnC levels ranged from 1.43 to 57.53 micrograms/ml. Blood samples from 18 of the 34 patients were cultured. S. pneumoniae grew in the culture of a blood sample from one patient, whose sputum also had the highest PnC level. Of 22 sputum samples from patients with pneumonia that did not grow S. pneumonia, two were positive by EIA (specificity, 90.1%). Sputa from both patients had low levels of PnC (2.7 and 4.5 micrograms/ml), and both patients had received antibiotics before sputum collection. The positive predictive value of the quantitative EIA was 85.7%. Quantitation of PnC has the potential for improving the accuracy of sputum examination for S. pneumoniae, monitoring disease severity and the effectiveness of antibiotic therapy, and differentiating between those patients with invasive pneumococcal disease and those who are carriers of S. pneumoniae.


J Clin Microbiol. 1992 February; 30(2): 318-322




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1992 by the American Society for Microbiology. All rights reserved.