JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dimech, W
Right arrow Articles by Skurrie, I
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dimech, W
Right arrow Articles by Skurrie, I

 Previous Article  |  Next Article 

J Clin Microbiol. 1992 March; 30(3): 633-641

Multicenter evaluation of five commercial rubella virus immunoglobulin G kits which report in international units per milliliter.

W Dimech, A Bettoli, D Eckert, B Francis, J Hamblin, T Kerr, C Ryan and I Skurrie

Department of Microbiology, Royal Melbourne Hospital, Parkville, Victoria, Australia.

ABSTRACT

In a multicenter study, the consistency of international units expressed by five commercially available rubella virus immunoglobulin G kits was evaluated. The linearity and within-run and between-run precision were determined for each kit. All kits demonstrated good linearity and had within-run and between-run precision coefficients of variation ranging from 5.1 to 21.7% and from 9.5 to 51.0%, respectively. To compare the international units expressed, the results from 40 samples tested in duplicate were compared with the results of a reference enzyme immunoassay calibrated with World Health Organization international standard serum and a hemagglutination inhibition test. The results of the kits were plotted against those of the reference tests, and linear regression analysis was applied. The Pearson correlation coefficient ranged from 0.64 to 0.75 when the commercial kit results were compared with those of the reference enzyme immunoassay, indicating only a moderate degree of correlation. Therefore, the international units expressed by the commercial kits are insufficiently consistent to be of practical use in diagnostic clinical microbiology.


J Clin Microbiol. 1992 March; 30(3): 633-641




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1992 by the American Society for Microbiology. All rights reserved.