JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yamanaka, T
Right arrow Articles by Yoshida, T
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yamanaka, T
Right arrow Articles by Yoshida, T
J Clin Microbiol. 1992 March; 30(3): 685-690

Detection of cytomegalovirus in urine samples by an enzyme-linked immunosorbent assay using a monoclonal antibody against the viral 150-kilodalton protein.

T Yamanaka, K Kiyotani, T Sakaguchi, Y Fukuda, K Dohi, M Yamada, M Yoshida, S Nii and T Yoshida

Department of Bacteriology, Hiroshima University School of Medicine, Japan.

ABSTRACT

McKeating et al. (J.A. McKeating, P.D. Griffiths, and J.E. Grundy, J. Gen. Virol. 68:785-792, 1987; J. A. McKeating, J. E. Grundy, Z. Varghese, and P. D. Griffiths, J. Med. Virol. 18:341-348, 1986; J. A. McKeating, S. Stagno, P. R. Stirk, and P. D. Griffiths, J. Med. Virol. 16:367-373, 1985) reported previously that beta 2 microglobulin inhibits the detection of human cytomegalovirus (CMV) in urine specimens by an enzyme-linked immunosorbent assay (ELISA) with a monoclonal antibody against the glycoprotein of CMV. They postulated that beta 2 microglobulin binds to the viral glycoproteins and masks the antigenic determinants. We developed here an ELISA method for the detection of CMV in urine by using a monoclonal antibody against the viral 150-kDa protein to capture the viral antigen. This assay detected CMV both in culture medium and in urine specifically at concentrations higher than 10(3) PFU/ml and quantitatively at concentrations higher than 10(4) PFU/ml. The sensitivity of the ELISA increased about 10-fold when peroxidase-labeled F(ab')2 from goat anti-human immunoglobulin G was used as a secondary detecting antibody in combination with concentration of the virus in urine samples by ultracentrifugation. The inhibition of ELISA by beta 2 microglobulin was not observed in this ELISA system. When 56 urine specimens from renal transplant recipients were examined for CMV antigens, the ELISA system had a sensitivity of 78% and a specificity of 97%. The positive and negative predictive values of the assay were 95 and 86%, respectively. Furthermore, CMV antigens in urine were quantitated by the assay during the course of typical CMV disease of renal transplant recipient. These results suggest strongly that the measurement of CMV antigens in urine by our rapid and quantitative ELISA system provides very useful data for the monitoring of CMV infections in renal transplant recipients and making decisions about therapy.


J Clin Microbiol. 1992 March; 30(3): 685-690







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1992 by the American Society for Microbiology. All rights reserved.