Previous Article | Next Article 
J Clin Microbiol. 1992 May; 30(5): 1179-1182
Stability of human immunodeficiency virus type 1 antibodies in whole blood dried on filter paper and stored under various tropical conditions in Kinshasa, Zaire.
F Behets,
M Kashamuka,
M Pappaioanou,
T A Green,
R W Ryder,
V Batter,
J R George,
W H Hannon and
T C Quinn
Projet SIDA, Kinshasa, Zaire.
ABSTRACT
The use of whole-blood spots on filter paper for the detection of antibody to human immunodeficiency virus type 1 (HIV-1) was evaluated during a 20-week period under a variety of storage environments simulating the harsh tropical field conditions in Kinshasa, Zaire. During the first 6 weeks of storage, all replicates of high- and low-titer HIV-1-positive reference samples remained positive by enzyme immunoassay and Western blotting (immunoblotting), and all replicates of HIV-1-negative samples remained negative under all storage conditions. However, hot and humid storage conditions for up to 20 weeks caused a progressive decline in enzyme immunoassay optical density ratio values, which was particularly noticeable in samples with a low HIV-1 antibody titer. Harsh tropical operational conditions did not cause any repeatedly false-positive results during the 20-week storage period. The use of gas-impermeable bags with desiccant for the storage of blood spots on filter paper improved the stability of HIV-1 antibody detection over time and is recommended for the storage of whole-blood spots on filter paper in harsh tropical field settings.
J Clin Microbiol. 1992 May; 30(5): 1179-1182
This article has been cited by other articles:
-
Mitchell, C., Jennings, C., Brambilla, D., Aldrovandi, G., Amedee, A. M., Beck, I., Bremer, J. W., Coombs, R., Decker, D., Fiscus, S., Fitzgibbon, J., Luzuriaga, K., Moye, J., Palumbo, P., Reichelderfer, P., Somasundaran, M., Stevens, W., Frenkel, L., for the Dried Blood Spot Working Group of the Infa,
(2008). Diminished Human Immunodeficiency Virus Type 1 DNA Yield from Dried Blood Spots after Storage in a Humid Incubator at 37{degrees}C Compared to -20{degrees}C. J. Clin. Microbiol.
46: 2945-2949
[Abstract]
[Full Text]
-
Fachiroh, J., Prasetyanti, P. R., Paramita, D. K., Prasetyawati, A. T., Anggrahini, D. W., Haryana, S. M., Middeldorp, J. M.
(2008). Dried-Blood Sampling for Epstein-Barr Virus Immunoglobulin G (IgG) and IgA Serology in Nasopharyngeal Carcinoma Screening. J. Clin. Microbiol.
46: 1374-1380
[Abstract]
[Full Text]
-
Patton, J. C., Coovadia, A. H., Meyers, T. M., Sherman, G. G.
(2008). Evaluation of the Ultrasensitive Human Immunodeficiency Virus Type 1 (HIV-1) p24 Antigen Assay Performed on Dried Blood Spots for Diagnosis of HIV-1 Infection in Infants. CVI
15: 388-391
[Abstract]
[Full Text]
-
Opstelten, W., van Loon, A. M., Schuller, M., van Wijck, A. J. M., van Essen, G. A., Moons, K. G. M., Verheij, T. J. M.
(2007). Clinical Diagnosis of Herpes Zoster in Family Practice. Ann Fam Med
5: 305-309
[Abstract]
[Full Text]
-
Ayele, W., Schuurman, R., Messele, T., Dorigo-Zetsma, W., Mengistu, Y., Goudsmit, J., Paxton, W. A., de Baar, M. P., Pollakis, G.
(2007). Use of Dried Spots of Whole Blood, Plasma, and Mother's Milk Collected on Filter Paper for Measurement of Human Immunodeficiency Virus Type 1 Burden. J. Clin. Microbiol.
45: 891-896
[Abstract]
[Full Text]
-
Patton, J. C., Sherman, G. G., Coovadia, A. H., Stevens, W. S., Meyers, T. M.
(2006). Ultrasensitive Human Immunodeficiency Virus Type 1 p24 Antigen Assay Modified for Use on Dried Whole-Blood Spots as a Reliable, Affordable Test for Infant Diagnosis. CVI
13: 152-155
[Abstract]
[Full Text]
-
Brambilla, D., Jennings, C., Aldrovandi, G., Bremer, J., Comeau, A. M., Cassol, S. A., Dickover, R., Jackson, J. B., Pitt, J., Sullivan, J. L., Butcher, A., Grosso, L., Reichelderfer, P., Fiscus, S. A.
(2003). Multicenter Evaluation of Use of Dried Blood and Plasma Spot Specimens in Quantitative Assays for Human Immunodeficiency Virus RNA: Measurement, Precision, and RNA Stability. J. Clin. Microbiol.
41: 1888-1893
[Abstract]
[Full Text]
-
Riddell, M. A., Leydon, J. A., Catton, M. G., Kelly, H. A.
(2002). Detection of Measles Virus-Specific Immunoglobulin M in Dried Venous Blood Samples by Using a Commercial Enzyme Immunoassay. J. Clin. Microbiol.
40: 5-9
[Abstract]
[Full Text]
-
Mei, J. V., Alexander, J. R., Adam, B. W., Hannon, W. H.
(2001). Use of Filter Paper for the Collection and Analysis of Human Whole Blood Specimens. J. Nutr.
131: 1631S-1636
[Abstract]
[Full Text]
-
Kotler, D. P, Thea, D. M, Heo, M., Allison, D. B, Engelson, E. S, Wang, J., Pierson, R. N Jr, Louis, M. S., Keusch, G. T
(1999). Relative influences of sex, race, environment, and HIV infection on body composition in adults. Am. J. Clin. Nutr.
69: 432-439
[Abstract]
[Full Text]
Copyright © 1992 by the American Society for Microbiology. All rights reserved.