JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ojeh, C K
Right arrow Articles by Saif, L J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ojeh, C K
Right arrow Articles by Saif, L J

 Previous Article  |  Next Article 

J Clin Microbiol. 1992 July; 30(7): 1667-1673

Development of a biotin-streptavidin-enhanced enzyme-linked immunosorbent assay which uses monoclonal antibodies for detection of group C rotaviruses.

C K Ojeh, H Tsunemitsu, R A Simkins and L J Saif

Ohio Agricultural Research and Development Center, Ohio State University, Wooster 44691.

ABSTRACT

A biotin-streptavidin-enhanced enzyme-linked immunosorbent assay (ELISA) which uses monoclonal antibodies (MAbs) for the detection of group C rotaviruses was developed. An assay in which plates were coated with three pooled MAbs and biotinylated polyclonal immunoglobulin G (IgG) (polyclonal antibody [PAb]) was used as the detector (MAb capture-PAb detector) was found to be the most sensitive and specific of the assays when it was compared with assays in which plates were coated with polyclonal antiserum and detection was done with either biotinylated polyclonal antiserum (PAb capture-PAb detector) or biotinylated pooled MAbs (PAb capture-MAb detector). The MAb capture-PAb detector ELISA detected 83% of samples confirmed to be positive for group C rotaviruses, whereas the PAb capture-PAb detector assay detected 63% of positive samples and the PAb capture-MAb detector assay detected 65% of positive samples. All three procedures detected both of the bovine and the two human group C rotaviruses, but none of the three procedures detected fecal samples containing group A and B rotaviruses or fecal samples negative for group C rotaviruses used in this study. The sensitivity of the MAb capture-PAb detector ELISA was determined by serially diluting fecal group C rotaviruses; antigens were detected in maximal positive dilution ranges of 1:1,000 to 1:3,000 for the samples tested. On the basis of the cell culture immunofluorescence assay infectivity titer of semipurified cell culture-passaged Cowden group C rotavirus, the sensitivity of the MAb capture-PAb detection ELISA for detection of homologous group C rotavirus was 53 fluorescent focus units per ml. Epitope mapping by use of the biotinylated MAbs in competition assay suggested that our MAbs may bind to three different but overlapping epitopes. These results suggest that the MAb capture-PAb detector ELISA can be used to study the epidemiology of group C rotaviruses in humans and animals.


J Clin Microbiol. 1992 July; 30(7): 1667-1673







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1992 by the American Society for Microbiology. All rights reserved.