JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ramamurthy, T
Right arrow Articles by Nair, G B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ramamurthy, T
Right arrow Articles by Nair, G B
J Clin Microbiol. 1992 July; 30(7): 1783-1786

Evaluation of the bead enzyme-linked immunosorbent assay for detection of cholera toxin directly from stool specimens.

T Ramamurthy, S K Bhattacharya, Y Uesaka, K Horigome, M Paul, D Sen, S C Pal, T Takeda, Y Takeda and G B Nair

National Institute of Cholera and Enteric Diseases, CIT Scheme XM, Beliaghata, Calcutta, India.

ABSTRACT

A highly sensitive bead enzyme-linked immunosorbent assay (bead ELISA) for detection of cholera toxin (CT) was evaluated for direct detection of CT from stool specimens of patients with acute secretory diarrhea. Of the 75 stool samples examined, 59 yielded biochemically, and serologically confirmed strains of Vibrio cholerae O1. The bead ELISA was positive for CT in stool supernatants in 50 (84.7%) of the 59 samples from which V. cholerae O1 was isolated. In addition, the bead ELISA was positive for three stool specimens which were negative by culture. The free CT present in 48 of the 50 stool samples positive by culture for V. cholerae O1 and for CT by bead ELISA was completely absorbed by anti-CT immunoglobulin G. All of the 59 strains of V. cholerae O1 biotype eltor isolated in this study produced in vitro CT. The concentration of CT present in the bead ELISA-positive stool samples ranged between 26 pg/ml and greater than 100 ng/ml. This evaluation study demonstrates that the bead ELISA is a sensitive and simple method for direct detection of CT in nonsterile stool samples, and we recommend routine use of this assay for detection of CT in stool samples and culture supernatants in clinical and reference laboratories.


J Clin Microbiol. 1992 July; 30(7): 1783-1786




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1992 by the American Society for Microbiology. All rights reserved.