JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Whittier, S
Right arrow Articles by Gilligan, P H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Whittier, S
Right arrow Articles by Gilligan, P H
J Clin Microbiol. 1993 November; 31(11): 2861-2865

Evaluation of four commercially available enzyme immunoassays for laboratory diagnosis of Clostridium difficile-associated diseases.

S Whittier, D S Shapiro, W F Kelly, T P Walden, K J Wait, L T McMillon and P H Gilligan

Clinical Microbiology Laboratory, University of North Carolina Hospitals, Chapel Hill 27599.

ABSTRACT

Four commercial enzyme immunoassays (EIAs) for the detection of Clostridium difficile toxin A have recently been developed and marketed (Premier, Meridian Diagnostics, Cincinnati, Ohio; VIDAS, bioMerierux Vitek, Inc., Hazelwood, Mo.; Tox-A-Test, TechLab, Blacksburg, Va.; and Bartels, Baxter Diagnostics, McGaw Park, Ill.). The performances of these EIAs were compared with those of the tissue culture cytotoxicity assay and a definition of C. difficile-associated disease based on both laboratory and clinical criteria for 329 clinical specimens. Two EIAs (Premier and VIDAS) showed good overall agreement (96 and 95%, respectively) with the cytotoxicity assay. However, they were less sensitive (84 and 71%, respectively) than the Bartels (94%) or Tox-A-Test (93%) EIAs. The Bartels and Tox-A-Test assays were much less specific, resulting in poor positive predictive values (56%) of the two assays when compared with that of the cytotoxicity assay. Tox-A-Test had the added drawback of having a significant number of indeterminate results (6.4%). These data indicate that the four EIAs all have specific shortcomings. When using these EIAs, testing strategies that take these shortcomings into consideration should be developed.


J Clin Microbiol. 1993 November; 31(11): 2861-2865