JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, J M
Right arrow Articles by McLaughlin, J C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, J M
Right arrow Articles by McLaughlin, J C
J Clin Microbiol. 1993 December; 31(12): 3170-3173

Evaluation of Biolog for identification of members of the family Micrococcaceae.

J M Miller, J W Biddle, V K Quenzer and J C McLaughlin

Hospital Infections Program, Centers for Disease Control and Prevention, Atlanta, Georgia 30333.

ABSTRACT

The Biolog Identification System (Biolog, Inc., Hayward, Calif.) was challenged at two separate laboratories with 113 coded isolates, including 33 type strains of staphylococci, 5 strains of Micrococcus spp., and 1 strain of Stomatococcus mucilaginosus. Test parameters between the sites were controlled as much as possible. Discrepancies were arbitrated by using conventional biochemicals. Overall accuracies (correct to the species level) upon initial testing were 47.7 and 59.3%, respectively, at the two laboratories. After repeat testing of isolates generating "no identification" responses or errors, the overall accuracies increased to 69.0 and 74.3% at the two sites, respectively, revealing no significant difference in the final results at the two laboratories (78 of 113 versus 84 of 113; P > 0.05). Error rates were 7.1% at one site and 9.7% at the other. The Biolog is not yet accurate enough to serve as a primary method for identifying staphylococci.


J Clin Microbiol. 1993 December; 31(12): 3170-3173




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1993 by the American Society for Microbiology. All rights reserved.