J Clin Microbiol. 1993 September; 31(9): 2356-2360
Preventing false positives: quantitative evaluation of three protocols for inactivation of polymerase chain reaction amplification products.
P N Rys and
D H Persing
Division of Clinical Microbiology, Mayo Clinic, Rochester, Minnesota 55905.
ABSTRACT
False-positive results because of carryover contamination by previously amplified nucleic acids are currently the greatest impediment to routine implementation of nucleic acid amplification protocols. We evaluated three methods for inactivation of a 156-bp Borrelia burgdorferi polymerase chain reaction (PCR) product: (i) post-PCR cross-linking with isopsoralen (IP), (ii) pre-PCR treatment of a dU-containing PCR product with uracil N-glycosylase (UNG), and (iii) post-PCR alkaline hydrolysis (primer hydrolysis) of PCR products synthesized by using primers containing 3' ribose residues. The sensitivities of the PCR performed under the conditions of each protocol were comparable. Inactivation of amplified DNA was highly efficient for all three protocols; the IP and UNG protocols eliminated at least to 3 x 10(9) copies of the product. The primer hydrolysis protocol varied in efficiency depending on the number and position of the 3' ribose residues, but inactivation ranged from 10(4) to 10(9) copies. We conclude that with some modifications, all three systems are effective for eliminating amplified DNA products. Routine implementation of at least one method should help to avoid false-positive results because of carryover contamination.
J Clin Microbiol. 1993 September; 31(9): 2356-2360
This article has been cited by other articles:
-
Tetzner, R., Dietrich, D., Distler, J.
(2007). Control of carry-over contamination for PCR-based DNA methylation quantification using bisulfite treated DNA. Nucleic Acids Res
35: e4-e4
[Abstract]
[Full Text]
-
Aslanzadeh, J.
(2004). Preventing PCR Amplification Carryover Contamination in a Clinical Laboratory. Annals of Clinical & Laboratory Science
34: 389-396
[Abstract]
[Full Text]
-
Sheppard, C. L., Harrison, T. G., Morris, R., Hogan, A., George, R. C.
(2004). Autolysin-targeted LightCycler assay including internal process control for detection of Streptococcus pneumoniae DNA in clinical samples. J Med Microbiol
53: 189-195
[Abstract]
[Full Text]
-
Hendolin, P. H., Paulin, L., Ylikoski, J.
(2000). Clinically Applicable Multiplex PCR for Four Middle Ear Pathogens. J. Clin. Microbiol.
38: 125-132
[Abstract]
[Full Text]
-
Schutzer, S. E., Coyle, P. K., Reid, P., Holland, B.
(1999). Borrelia burgdorferi-Specific Immune Complexes in Acute Lyme Disease. JAMA
282: 1942-1946
[Abstract]
[Full Text]
-
Tang, Y.-W., Mitchell, P. S., Espy, M. J., Smith, T. F., Persing, D. H.
(1999). Molecular Diagnosis of Herpes Simplex Virus Infections in the Central Nervous System. J. Clin. Microbiol.
37: 2127-2136
[Full Text]
-
Kessler, H. H., Jungkind, D., Stelzl, E., Direnzo, S., Vellimedu, S. K., Pierer, K., Santner, B., Marth, E.
(1999). Evaluation of AMPLILINK Software for the COBAS AMPLICOR System. J. Clin. Microbiol.
37: 436-437
[Abstract]
[Full Text]
-
Fahle, G. A., Gill, V. J., Fischer, S. H.
(1999). Optimal Activation of Isopsoralen To Prevent Amplicon Carryover. J. Clin. Microbiol.
37: 261-262
[Abstract]
[Full Text]
-
Reischl, U., Lehn, N., Wolf, H., Naumann, L.
(1998). Clinical Evaluation of the Automated COBAS AMPLICOR MTB Assay for Testing Respiratory and Nonrespiratory Specimens. J. Clin. Microbiol.
36: 2853-2860
[Abstract]
[Full Text]
-
Albadalejo, J., Alonso, R., Antinozzi, R., Bogard, M., Bourgault, A.-M., Colucci, G., Fenner, T., Petersen, H., Sala, E., Vincelette, J., Young, C.
(1998). Multicenter Evaluation of the COBAS AMPLICOR HCV Assay, an Integrated PCR System for Rapid Detection of Hepatitis C Virus RNA in the Diagnostic Laboratory. J. Clin. Microbiol.
36: 862-865
[Abstract]
[Full Text]
-
Gibson, N. J., Gillard, H. L., Whitcombe, D., Ferrie, R. M., Newton, C. R., Little, S.
(1997). A homogeneous method for genotyping with fluorescence polarization. Clin. Chem.
43: 1336-1341
[Abstract]
[Full Text]
-
Niederhauser, C, Hofelein, C, Wegmuller, B, Luthy, J, Candrian, U
(1994). Reliability of PCR decontamination systems.. Genome Res.
4: 117-123
[Abstract]
Copyright © 1993 by the American Society for Microbiology. All rights reserved.