JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Altaie, S S
Right arrow Articles by Dryja, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Altaie, S S
Right arrow Articles by Dryja, D
J Clin Microbiol. 1994 January; 32(1): 51-53

Comparison of two commercially available enzyme immunoassays for detection of Clostridium difficile in stool specimens.

S S Altaie, P Meyer and D Dryja

Department of Pediatrics, School of Medicine and Biomedical Sciences, State University of New York, Buffalo.

ABSTRACT

Clostridium difficile is the cause of most cases of pseudomembranous colitis, the most severe form of antibiotic-associated diarrhea. Rapid diagnosis guides both the treatment and the control of nosocomial spread of infection. Two enzyme immunoassay (EIA) kits developed for the rapid detection of C. difficile toxin A in fecal specimens, Premier (Meridian Diagnostics, Cincinnati, Ohio) and Tox-A test (TechLab, Virginia Polytechnic Institute Research Park, Blacksburg), were evaluated by using 410 fecal specimens. Seventy-six specimens were positive for C. difficile toxin B by the cytotoxin assay (prevalence rate, 19%). The Meridian EIA was positive for 71 of the 76 samples, yielding a sensitivity of 93%. The TechLab EIA detected 75 of the 76 positive samples, yielding a sensitivity of 99%. The Meridian and TechLab EIAs had specificities of 100 and 93%, respectively. These data indicate that both EIAs are suitable alternatives to the cytotoxin assay in routine diagnostic laboratories. However, confirmation of TechLab EIA-positive test results by the cytotoxin assay remains necessary.


J Clin Microbiol. 1994 January; 32(1): 51-53




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1994 by the American Society for Microbiology. All rights reserved.