JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kirkley, B A
Right arrow Articles by Washington, J A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kirkley, B A
Right arrow Articles by Washington, J A

 Previous Article  |  Next Article 

J Clin Microbiol. 1994 June; 32(6): 1547-1549

Controlled clinical evaluation of Isolator and ESP aerobic blood culture systems for detection of bloodstream infections.

B A Kirkley, K A Easley and J A Washington

Department of Clinical Pathology, Cleveland Clinic Foundation, Ohio 44195-5140.

ABSTRACT

A controlled clinical evaluation comparing the Isolator system (Wampole Laboratories, Cranbury, N.J.) and the ESP 80A blood culture bottle in the automated ESP system (Difco Laboratories, Detroit, Mich.) was performed with 10,535 blood culture sets from patients with suspected septicemia. Of 1,150 positive cultures, 844 positive cultures from 285 patients with 394 septic episodes fulfilled the study criteria for minimum blood sample requirements in each system and clinical significance of isolates. The Isolator system detected statistically significantly more positive cultures of Staphylococcus aureus (P < 0.001), Enterococcus spp. (P = 0.007), Escherichia coli (P = 0.001), Alcaligenes xylosoxidans (P = 0.02), Xanthomonas maltophilia (P = 0.01), Candida albicans (P < 0.001), and Candida glabrata (P = 0.05). The Isolator system detected significantly more septic episodes due to S. aureus (P < 0.001), X. maltophilia (P = 0.02), and C. albicans (P = 0.004) than did the ESP 80A bottle; however, the two systems did not otherwise significantly differ in their abilities to detect septic episodes due to other organisms.


J Clin Microbiol. 1994 June; 32(6): 1547-1549




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1994 by the American Society for Microbiology. All rights reserved.