JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kellogg, J A
Right arrow Articles by Cavanaugh, S H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kellogg, J A
Right arrow Articles by Cavanaugh, S H
J Clin Microbiol. 1994 September; 32(9): 2050-2055

Clinical comparison of isolator and thiol broth with ESP aerobic and anaerobic bottles for recovery of pathogens from blood.

J A Kellogg, D A Bankert, J P Manzella, K S Parsey, S L Scott and S H Cavanaugh

Department of Pathology, York Hospital, York, Pennsylvania 17405.

ABSTRACT

The recovery of pathogens and the speed of their detection were determined for our conventional blood culture system (an Isolator [Wampole] and a 100-ml Thiol bottle [Difco]) compared with automated ESP aerobic and anaerobic bottles (80 ml each; Difco). Each of the four culture devices was inoculated with approximately 10 ml of blood from symptomatic patients weighing more than 80 lb (ca. 36 kg). From 7,070 sets of cultures for 2,841 patients, 607 clinically significant isolates were recovered: 456 (75.1%) from the Isolator, 353 (58.2%) from Thiol, 377 (62.1%) from ESP aerobic bottles, and 346 (57.0%) from ESP anaerobic bottles. Of the 607 isolates, 149 (24.5%) were detected only with the conventional system (Isolator and/or Thiol), and 65 (10.7%) were detected only with the ESP two-bottle system (P < 0.001). Our conventional system allowed for detection of significantly more isolates of members of the family Enterobacteriaceae (P < 0.001), Staphylococcus aureus (P < 0.01), Staphylococcus spp. (coagulase-negative) (P < 0.01), and Enterococcus spp. (P < 0.05), and ESP facilitated detection of significantly more isolates of S. pneumoniae (P < 0.01). When all four devices in a culture set were positive for the same isolate, no microbial species or group was detected significantly earlier ( > or = 24 h) by either blood culture system. The Isolator contamination rate (4.8%) was > or = 6 times the rate for any of the bottles. Of pathogens detected by the Isolator, 50% were recovered in counts of < or = 1.0 CFU/ml and 18% were recovered only as a single colony. The ESP system offered an automated, less labor-intensive blood culture system for which routine subcultures were not required, but the important considerations of culturing large volumes of blood and of obtaining at least two sets from each patient in our population were reemphasized.


J Clin Microbiol. 1994 September; 32(9): 2050-2055




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1994 by the American Society for Microbiology. All rights reserved.