This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Spaargaren, J.
Right arrow Articles by Voorn, G. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Spaargaren, J.
Right arrow Articles by Voorn, G. P.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, December 1998, p. 3731-3733, Vol. 36, No. 12
0095-1137/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.

Effectiveness of Resins in Neutralizing Antibiotic Activities in Bactec Plus Aerobic/F Culture Medium

J. Spaargaren,1 C. P. A. van Boven,1 and G. P. Voorn2,*

Department of Medical Microbiology, Leiden University Medical Centre, 2300 RC, Leiden,1 and Department of Medical Microbiology, St. Antonius Hospital, 3420 EM, Nieuwegein,2 The Netherlands

Received 17 February 1998/Returned for modification 20 May 1998/Accepted 10 September 1998

Incorporating resins in blood culture media can effectively reduce the activities of several antibiotics. It was shown that the activities of some generally used antibiotics decreased by 80 to 90% within 2 h in Bactec Plus Aerobic/F resin-containing culture medium. Bactec vials containing resins were still found to be positive for bacteria when antibiotics were present. The addition of beta -lactamase shortened the detection time irrespective of the presence of resins.


* Corresponding author. Mailing address: St. Antonius Hospital, Department of Medical Microbiology, P.O. Box 2500, 3420 EM, Nieuwegein, The Netherlands. Phone: 31 30 6092624. Fax: 31 30 6092429. E-mail: mmiazn{at}knmg.nl.


Journal of Clinical Microbiology, December 1998, p. 3731-3733, Vol. 36, No. 12
0095-1137/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Flayhart, D., Borek, A. P., Wakefield, T., Dick, J., Carroll, K. C. (2007). Comparison of BACTEC PLUS Blood Culture Media to BacT/Alert FA Blood Culture Media for Detection of Bacterial Pathogens in Samples Containing Therapeutic Levels of Antibiotics. J. Clin. Microbiol. 45: 816-821 [Abstract] [Full Text]  