This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Halling, V. W.
Right arrow Articles by Cockerill, F. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Halling, V. W.
Right arrow Articles by Cockerill, F. R., III

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, October 1999, p. 3233-3234, Vol. 37, No. 10
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.

Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing

V. W. Halling, M. F. Jones, J. E. Bestrom, A. D. Wold, J. E. Rosenblatt, T. F. Smith, and F. R. Cockerill III*

Mayo Clinic Rochester, Rochester, Minnesota

Received 4 March 1999/Returned for modification 4 June 1999/Accepted 29 June 1999

Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of >= 0.650 and <= 0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.


* Corresponding author. Mailing address: Division of Clinical Microbiology, Mayo Clinic, 200 First St. SW, Rochester, MN 55905. Phone: (507) 284-2901. Fax: (507) 284-4272. E-mail: cockerill.franklin{at}mayo.edu.


Journal of Clinical Microbiology, October 1999, p. 3233-3234, Vol. 37, No. 10
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Woznicova, V., Valisova, Z. (2007). Performance of CAPTIA SelectSyph-G Enzyme-Linked Immunosorbent Assay in Syphilis Testing of a High-Risk Population: Analysis of Discordant Results. J. Clin. Microbiol. 45: 1794-1797 [Abstract] [Full Text]  
  • Aubry, A., Porcher, R., Bottero, J., Touratier, S., Leblanc, T., Brethon, B., Rousselot, P., Raffoux, E., Menotti, J., Derouin, F., Ribaud, P., Sulahian, A. (2006). Occurrence and Kinetics of False-Positive Aspergillus Galactomannan Test Results following Treatment with {beta}-Lactam Antibiotics in Patients with Hematological Disorders. J. Clin. Microbiol. 44: 389-394 [Abstract] [Full Text]  
  • Marangoni, A., Sambri, V., Accardo, S., Cavrini, F., D'Antuono, A., Moroni, A., Storni, E., Cevenini, R. (2005). Evaluation of LIAISON Treponema Screen, a Novel Recombinant Antigen-Based Chemiluminescence Immunoassay for Laboratory Diagnosis of Syphilis. CVI 12: 1231-1234 [Abstract] [Full Text]  
  • Castro, R., Prieto, E. S., Santo, I., Azevedo, J., Exposto, F. d. L. (2003). Evaluation of an Enzyme Immunoassay Technique for Detection of Antibodies against Treponema pallidum. J. Clin. Microbiol. 41: 250-253 [Abstract] [Full Text]  
  • Sambri, V., Marangoni, A., Eyer, C., Reichhuber, C., Soutschek, E., Negosanti, M., D'Antuono, A., Cevenini, R. (2001). Western Immunoblotting with Five Treponema pallidum Recombinant Antigens for Serologic Diagnosis of Syphilis. CVI 8: 534-539 [Abstract] [Full Text]  
  • Young, H (2000). Guidelines for serological testing for syphilis. Sex. Transm. Infect. 76: 403-405 [Full Text]