JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, S. C.
Right arrow Articles by Rosenstraus, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, S. C.
Right arrow Articles by Rosenstraus, M.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, November 2000, p. 4171-4179, Vol. 38, No. 11
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.

Improved Version 2.0 Qualitative and Quantitative AMPLICOR Reverse Transcription-PCR Tests for Hepatitis C Virus RNA: Calibration to International Units, Enhanced Genotype Reactivity, and Performance Characteristics

Sung C. Lee, Anisha Antony, Nitta Lee, Jeff Leibow, Jian Q. Yang, Stephen Soviero, Karen Gutekunst, and Maurice Rosenstraus*

Roche Molecular Systems, Inc., Pleasanton, California

Received 9 February 2000/Returned for modification 30 May 2000/Accepted 21 August 2000

Version 2.0 qualitative and quantitative AMPLICOR reverse transcription-PCR tests for HCV were designed to improve on the performance of first version of the hepatitis C virus (HCV) tests. The new tests were calibrated in international units, the new commonly accepted standard unit of measurement for HCV RNA. The sensitivity of the qualitative tests was enhanced by modifying the specimen processing procedure to achieve a limit of detection 50 IU/ml. The limit of detection for the quantitative tests was 600 IU/ml. Modifications to the amplification reaction mixture and thermal cycling conditions enabled all genotypes to be amplified with similar efficiency. The quantitative tests exhibited a linear range extending from 500 to 500,000 IU/ml and excellent reproducibility, with coefficients of variation ranging from 18 to 39%, within the linear range. These data indicate that the version 2.0 AMPLICOR HCV tests will improve diagnosis of HCV infection and will yield more-accurate titers for prognosis and for monitoring therapeutic efficacy, particularly at low viral loads. Furthermore, it will be possible to compare the performance characteristics and viral load measurements of AMPLICOR tests to those of other tests that adopt the international unit as the standard of measurement.


* Corresponding author. Present address: Roche Molecular Systems, 1080 Route 202, Somerville, NJ 08876. Phone: (908) 253-7463. Fax: (908) 253-3318. E-mail: maurice.rosenstraus{at}roche.com.


Journal of Clinical Microbiology, November 2000, p. 4171-4179, Vol. 38, No. 11
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 2000 by the American Society for Microbiology. All rights reserved.