This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ballard, A. L.
Right arrow Articles by Towner, K. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ballard, A. L.
Right arrow Articles by Towner, K. J.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, November 2000, p. 4215-4218, Vol. 38, No. 11
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.

Detection of Legionella pneumophila Using a Real-Time PCR Hybridization Assay

A. L. Ballard,1 N. K. Fry,2 L. Chan,3 S. B. Surman,3 J. V. Lee,3 T. G. Harrison,2 and K. J. Towner1,*

Department of Microbiology and PHLS Laboratory, University Hospital,1 and PHLS Water and Environmental Microbiology Research Unit,3 Queen's Medical Centre, Nottingham NG7 2UH, and Respiratory and Systemic Infection Laboratory, PHLS Central Public Health Laboratory, London NW9 5HT,2 United Kingdom

Received 29 March 2000/Returned for modification 8 June 2000/Accepted 18 August 2000

A real-time PCR hybridization assay for Legionella pneumophila is described; the assay uses LightCycler (Idaho Technology) methodology to specifically detect 2.5 CFU/reaction, equivalent to 1,000 CFU/liter of starting water sample. The assay, including DNA extraction and confirmation of product identity, is completed within 90 min of receipt of a sample.


* Corresponding author. Mailing address: Department of Microbiology and PHLS Laboratory, University Hospital, Queen's Medical Centre, Nottingham NG7 2UH, United Kingdom. Phone: 44-115-9709163. Fax: 44-115-9422190. E-mail: Kevin.Towner{at}nottingham.ac.uk.


Journal of Clinical Microbiology, November 2000, p. 4215-4218, Vol. 38, No. 11
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Delgado-Viscogliosi, P., Solignac, L., Delattre, J.-M. (2009). Viability PCR, a Culture-Independent Method for Rapid and Selective Quantification of Viable Legionella pneumophila Cells in Environmental Water Samples. Appl. Environ. Microbiol. 75: 3502-3512 [Abstract] [Full Text]  
  • Diederen, B. M. W., Kluytmans, J. A. J. W., Vandenbroucke-Grauls, C. M., Peeters, M. F. (2008). Utility of Real-Time PCR for Diagnosis of Legionnaires' Disease in Routine Clinical Practice. J. Clin. Microbiol. 46: 671-677 [Abstract] [Full Text]  
  • Bencini, M. A., van den Brule, A. J. C., Claas, E. C. J., Hermans, M. H. A., Melchers, W. J. G., Noordhoek, G. T., Salimans, M. M. M., Schirm, J., Vink, C., van der Zee, A., Jansen, R. (2007). Multicenter Comparison of Molecular Methods for Detection of Legionella spp. in Sputum Samples. J. Clin. Microbiol. 45: 3390-3392 [Abstract] [Full Text]  
  • Yaradou, D. F., Hallier-Soulier, S., Moreau, S., Poty, F., Hillion, Y., Reyrolle, M., Andre, J., Festoc, G., Delabre, K., Vandenesch, F., Etienne, J., Jarraud, S. (2007). Integrated Real-Time PCR for Detection and Monitoring of Legionella pneumophila in Water Systems. Appl. Environ. Microbiol. 73: 1452-1456 [Abstract] [Full Text]  
  • Gilmour, M. W., Bernard, K., Tracz, D. M., Olson, A. B., Corbett, C. R., Burdz, T., Ng, B., Wiebe, D., Broukhanski, G., Boleszczuk, P., Tang, P., Jamieson, F., Van Domselaar, G., Plummer, F. A., Berry, J. D. (2007). Molecular typing of a Legionella pneumophila outbreak in Ontario, Canada. J Med Microbiol 56: 336-341 [Abstract] [Full Text]  
  • Diederen, B. M. W., de Jong, C. M. A., Marmouk, F., Kluytmans, J. A. J. W., Peeters, M. F., Van der Zee, A. (2007). Evaluation of real-time PCR for the early detection of Legionella pneumophila DNA in serum samples. J Med Microbiol 56: 94-101 [Abstract] [Full Text]  
  • Diederen, B. M. W., de Jong, C. M. A., Kluytmans, J. A. J. W., van der Zee, A., Peeters, M. F. (2006). Detection and quantification of Legionella pneumophila DNA in serum: case reports and review of the literature.. J Med Microbiol 55: 639-642 [Abstract] [Full Text]  
  • Joly, P., Falconnet, P.-A., Andre, J., Weill, N., Reyrolle, M., Vandenesch, F., Maurin, M., Etienne, J., Jarraud, S. (2006). Quantitative Real-Time Legionella PCR for Environmental Water Samples: Data Interpretation. Appl. Environ. Microbiol. 72: 2801-2808 [Abstract] [Full Text]  
  • Dirven, K., Ieven, M., Peeters, M. F, van der Zee, A., De Schrijver, K., Goossens, H. (2005). Comparison of three Legionella urinary antigen assays during an outbreak of legionellosis in Belgium. J Med Microbiol 54: 1213-1216 [Abstract] [Full Text]  
  • Valasek, M. A., Repa, J. J. (2005). The power of real-time PCR. Adv. Physiol. Educ. 29: 151-159 [Abstract] [Full Text]  
  • Yanez, M. A., Carrasco-Serrano, C., Barbera, V. M., Catalan, V. (2005). Quantitative Detection of Legionella pneumophila in Water Samples by Immunomagnetic Purification and Real-Time PCR Amplification of the dotA Gene. Appl. Environ. Microbiol. 71: 3433-3441 [Abstract] [Full Text]  
  • Delgado-Viscogliosi, P., Simonart, T., Parent, V., Marchand, G., Dobbelaere, M., Pierlot, E., Pierzo, V., Menard-Szczebara, F., Gaudard-Ferveur, E., Delabre, K., Delattre, J. M. (2005). Rapid Method for Enumeration of Viable Legionella pneumophila and Other Legionella spp. in Water. Appl. Environ. Microbiol. 71: 4086-4096 [Abstract] [Full Text]  
  • Raggam, R. B., Leitner, E., Berg, J., Muhlbauer, G., Marth, E., Kessler, H. H. (2005). Single-Run, Parallel Detection of DNA from Three Pneumonia-Producing Bacteria by Real-Time Polymerase Chain Reaction. J. Mol. Diagn. 7: 133-138 [Abstract] [Full Text]  
  • Herpers, B. L., de Jongh, B. M., van der Zwaluw, K., van Hannen, E. J. (2003). Real-Time PCR Assay Targets the 23S-5S Spacer for Direct Detection and Differentiation of Legionella spp. and Legionella pneumophila. J. Clin. Microbiol. 41: 4815-4816 [Abstract] [Full Text]  
  • Templeton, K. E., Scheltinga, S. A., Sillekens, P., Crielaard, J. W., van Dam, A. P., Goossens, H., Claas, E. C. J. (2003). Development and Clinical Evaluation of an Internally Controlled, Single-Tube Multiplex Real-Time PCR Assay for Detection of Legionella pneumophila and Other Legionella Species. J. Clin. Microbiol. 41: 4016-4021 [Abstract] [Full Text]  
  • Wilson, D. A., Yen-Lieberman, B., Reischl, U., Gordon, S. M., Procop, G. W. (2003). Detection of Legionella pneumophila by Real-Time PCR for the mip Gene. J. Clin. Microbiol. 41: 3327-3330 [Abstract] [Full Text]  
  • Miller, N., Cleary, T., Kraus, G., Young, A. K., Spruill, G., Hnatyszyn, H. J. (2002). Rapid and Specific Detection of Mycobacterium tuberculosis from Acid-Fast Bacillus Smear-Positive Respiratory Specimens and BacT/ALERT MP Culture Bottles by Using Fluorogenic Probes and Real-Time PCR. J. Clin. Microbiol. 40: 4143-4147 [Abstract] [Full Text]  
  • Reischl, U., Linde, H.-J., Lehn, N., Landt, O., Barratt, K., Wellinghausen, N. (2002). Direct Detection and Differentiation of Legionella spp. and Legionella pneumophila in Clinical Specimens by Dual-Color Real-Time PCR and Melting Curve Analysis. J. Clin. Microbiol. 40: 3814-3817 [Abstract] [Full Text]  
  • Fields, B. S., Benson, R. F., Besser, R. E. (2002). Legionella and Legionnaires' Disease: 25 Years of Investigation. Clin. Microbiol. Rev. 15: 506-526 [Abstract] [Full Text]  
  • van der Zee, A., Verbakel, H., de Jong, C., Pot, R., Bergmans, A., Peeters, M., Schneeberger, P., Schellekens, J. (2002). Novel PCR-Probe Assay for Detection of and Discrimination between Legionella pneumophila and Other Legionella Species in Clinical Samples. J. Clin. Microbiol. 40: 1124-1125 [Full Text]  
  • Wellinghausen, N., Frost, C., Marre, R. (2001). Detection of Legionellae in Hospital Water Samples by Quantitative Real-Time LightCycler PCR. Appl. Environ. Microbiol. 67: 3985-3993 [Abstract] [Full Text]