Previous Article | Next Article ![]()
Journal of Clinical Microbiology, December 2000, p. 4665-4667, Vol. 38, No. 12
Department of Pathology and Laboratory
Services, Denver Health Medical Center,1 and
Department of Pathology,2 University of
Colorado School of Medicine, Denver, Colorado; Clinical
Microbiology Laboratory, Robert Wood Johnson University
Hospital,3 and Departments of
Pathology4 and
Medicine,5 Robert Wood Johnson
Medical School, New Brunswick, New Jersey; Clinical
Microbiology Laboratory, Duke University Medical Center, Durham,
North Carolina6; Clinical Microbiology
Laboratory, Salt Lake City Veterans Affairs Medical
Center,7 and Department of Pathology,
University of Utah School of Medicine,8 Salt
Lake City, Utah; and Departments of
Pathology9 and
Medicine,10 Duke University School of
Medicine, Durham, North Carolina
Received 31 May 2000/Returned for modification 7 August
2000/Accepted 29 September 2000
Iodophor and alcohol pledgets were compared with the Medi-Flex Prep
Kit II for skin disinfection before venipuncture. Of 12,367 blood
cultures collected, 6,362 were done with conventional pledgets and
6,005 were done with Medi-Flex kits. Contamination occurred in 351 of
6,362 blood cultures (5.5%; range, 3.7 to 8.1%) with conventional
pledgets versus 328 of 6,005 (5.5%; range, 3.5 to 7.5%) with
Medi-Flex kits.
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.
Comparison of Iodophor and Alcohol Pledgets with
the Medi-Flex Blood Culture Prep Kit II for Preventing
Contamination of Blood Cultures
*
Corresponding author. Mailing address: Department of
Pathology and Laboratory Services, Denver Health Medical Center, Mail Code #0224, 777 Bannock, Denver, CO 80204-4507. Phone: (303) 436-6434. Fax: (303) 436-6420. E-mail: mwilson{at}dhha.org.
This article has been cited by other articles:
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»