This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wilson, M. L.
Right arrow Articles by Reller, L. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wilson, M. L.
Right arrow Articles by Reller, L. B.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, December 2000, p. 4665-4667, Vol. 38, No. 12
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.

Comparison of Iodophor and Alcohol Pledgets with the Medi-Flex Blood Culture Prep Kit II for Preventing Contamination of Blood Cultures

Michael L. Wilson,1,2,* Melvin P. Weinstein,3,4,5 Stanley Mirrett,6 Larry G. Reimer,7,8 Cha Fernando,5 Frances T. Meredith,6 and L. Barth Reller6,9,10

Department of Pathology and Laboratory Services, Denver Health Medical Center,1 and Department of Pathology,2 University of Colorado School of Medicine, Denver, Colorado; Clinical Microbiology Laboratory, Robert Wood Johnson University Hospital,3 and Departments of Pathology4 and Medicine,5 Robert Wood Johnson Medical School, New Brunswick, New Jersey; Clinical Microbiology Laboratory, Duke University Medical Center, Durham, North Carolina6; Clinical Microbiology Laboratory, Salt Lake City Veterans Affairs Medical Center,7 and Department of Pathology, University of Utah School of Medicine,8 Salt Lake City, Utah; and Departments of Pathology9 and Medicine,10 Duke University School of Medicine, Durham, North Carolina

Received 31 May 2000/Returned for modification 7 August 2000/Accepted 29 September 2000

Iodophor and alcohol pledgets were compared with the Medi-Flex Prep Kit II for skin disinfection before venipuncture. Of 12,367 blood cultures collected, 6,362 were done with conventional pledgets and 6,005 were done with Medi-Flex kits. Contamination occurred in 351 of 6,362 blood cultures (5.5%; range, 3.7 to 8.1%) with conventional pledgets versus 328 of 6,005 (5.5%; range, 3.5 to 7.5%) with Medi-Flex kits.


* Corresponding author. Mailing address: Department of Pathology and Laboratory Services, Denver Health Medical Center, Mail Code #0224, 777 Bannock, Denver, CO 80204-4507. Phone: (303) 436-6434. Fax: (303) 436-6420. E-mail: mwilson{at}dhha.org.


Journal of Clinical Microbiology, December 2000, p. 4665-4667, Vol. 38, No. 12
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Kiyoyama, T., Tokuda, Y., Shiiki, S., Hachiman, T., Shimasaki, T., Endo, K. (2009). Isopropyl Alcohol Compared with Isopropyl Alcohol plus Povidone-Iodine as Skin Preparation for Prevention of Blood Culture Contamination. J. Clin. Microbiol. 47: 54-58 [Abstract] [Full Text]  
  • Hall, K. K., Lyman, J. A. (2006). Updated Review of Blood Culture Contamination. Clin. Microbiol. Rev. 19: 788-802 [Abstract] [Full Text]  
  • Weinstein, M. P. (2003). Blood Culture Contamination: Persisting Problems and Partial Progress. J. Clin. Microbiol. 41: 2275-2278 [Full Text]