Previous Article | Next Article ![]()
Journal of Clinical Microbiology, July 2000, p. 2722-2725, Vol. 38, No. 7
Unité de Recherche INSERM U481, Centre
de Recherche Claude Bernard sur les Hépatites Virales and
Service d'Hépatologie, Hôpital Beaujon, 92110 Clichy,1 and Institut de Virologie de
la Faculté de Médecine, 67000 Strasbourg,2 France
Received 27 October 1999/Returned for modification 13 January
2000/Accepted 8 May 2000
The correlation between response to antiviral therapy and
pretreatment viral load in patients with chronic hepatitis C has prompted the development of quantitative assays to measure viral load.
The aim of our study was to assess the clinical relevance of the newly
developed semiautomated PCR system COBAS HCV MONITOR version 2.0 in
comparison with (i) the AMPLICOR HCV MONITOR version 1.0 assay, which
underestimates RNA concentration of hepatitis C virus (HCV) genotypes 2 to 6, and (ii) the QUANTIPLEX HCV RNA version 2.0 assay, which achieves
equivalent quantification for each HCV genotype, with samples from 174 patients diagnosed with chronic hepatitis C before therapy. The level
and range of quantification measured with AMPLICOR HCV MONITOR version
1.0 were 1 log lower than when measured with the COBAS HCV MONITOR
version 2.0, at 0.261 × 106 RNA copies/ml (range,
0.001 × 106 to 2.50 × 106 RNA
copies/ml) and 4.032 × 106 RNA copies/ml (range,
0.026 × 106 to 72.6 × 106 RNA
copies/ml), respectively. The two assays showed a poor correlation (r2 = 0.175). The level and range of
quantification were similar when measured with the COBAS HCV MONITOR
version 2.0 and QUANTIPLEX HCV RNA version 2.0 assays, at 3.03 × 106 RNA copies/ml (range, 0.023 × 106 to
72.6 × 106 RNA copies/ml) and 4.91 Meq/ml (range,
0.200 to 49.5 Meq/ml), respectively. The two assays showed a strong
correlation (r2 = 0.686) for each HCV
genotype. The duration of treatment (6 or 12 months) is modulated
according to HCV genotype and viral load. Our results indicate that
COBAS HCV MONITOR version 2.0 and QUANTIPLEX HCV RNA version 2.0 assays
showing an equal dynamic range for each HCV genotype are suitable tools
to assess patients before therapy.
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.
Assessment of Viral Loads in Patients with Chronic Hepatitis C
with AMPLICOR HCV MONITOR Version 1.0, COBAS HCV MONITOR Version
2.0, and QUANTIPLEX HCV RNA Version 2.0 Assays
*
Corresponding author. Mailing address: INSERM U481,
Hôpital Beaujon, 92118 Clichy-Cedex, France. Phone: 33 1 40 87 55 45. Fax: 33 1 47 30 94 40. E-mail:
martinot{at}bichat.inserm.fr.
This article has been cited by other articles:
| Antimicrob. Agents Chemother. | Clin. Microbiol. Rev. |
|---|---|
| Clin. Vaccine Immunol. | ALL ASM JOURNALS |
|---|