Journal of Clinical Microbiology, November 2002, p. 4015-4020, Vol. 40, No. 11
0095-1137/02/$04.00+0 DOI: 10.1128/JCM.40.11.4015-4020.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
Precision and Accuracy of a Procedure for Detecting Recent Human Immunodeficiency Virus Infections by Calculating the Antibody Avidity Index by an Automated Immunoassay-Based Method
Barbara Suligoi,1* Claudio Galli,2 Mario Massi,3 Fiorella Di Sora,4 Mauro Sciandra,5 Patrizio Pezzotti,1 Olga Recchia,3 Francesco Montella,4 Alessandro Sinicco,5 and Giovanni Rezza1
Reparto AIDS e MST, Istituto Superiore di Sanità,1
Scientific Affairs, Abbott Diagnostics Division,2
Patologia Clinica,3
Clinic of Infectious Diseases, Ospedale S. Giovanni-Addolorata, Rome,4
Clinic of Infectious Diseases, Università di Torino, Turin, Italy5
Received 18 April 2002/
Returned for modification 6 June 2002/
Accepted 31 July 2002
We evaluated the precision and accuracy of a procedure for detecting recent human immunodeficiency virus (HIV) infections, specifically, the avidity index (AI) calculated using a method based on an automated AxSYM HIV 1/2gO assay (Abbott). To evaluate precision, we performed multiple replicates on eight HIV-positive serum samples. To evaluate the accuracy in identifying recent infections (i.e., within 6 months of seroconversion), we used 216 serum samples from 47 persons whose dates of seroconversion were known. To evaluate the sensitivity and specificity of the procedure for different AI cutoff values, we performed receiver operating characteristic (ROC) analysis. To determine the effects of antiretroviral treatment, advanced stage of the disease (i.e., low CD4-cell count), and low HIV viral load on the AI, we analyzed 15 serum samples from 15 persons whose dates of seroconversion were unknown. The precision study showed that the procedure was robust (i.e., the total variance of the AI was lower than 10%). Regarding accuracy, the mean AI was significantly lower for samples collected within 6 months of seroconversion, compared to those collected afterwards (0.68 ± 0.16 versus 0.99 ± 0.10; P < 0.0001), with no overlap of the 95% confidence intervals. The ROC analysis revealed that an AI lower than 0.6 had a sensitivity of 33.3% and a specificity of 98.4%, compared to 87.9 and 86.3%, respectively, for an AI lower than 0.9. Antiretroviral treatment, low CD4-cell count, and low viral load had no apparent effect on the AI. In conclusion, this procedure is reproducible and accurate in identifying recent infections; it is automated, inexpensive, and easy to perform, and it provides a quantitative result with different levels of sensitivity and specificity depending on the selected cutoff.
* Corresponding author. Mailing address: Reparto AIDS e MST, Istituto Superiore di Sanità, V.le Regina Elena 299, 00161 Rome, Italy. Phone: (39) 06 4938 7209. Fax: (39) 06 4938 7210. E-mail: suligoi{at}iss.it.
Journal of Clinical Microbiology, November 2002, p. 4015-4020, Vol. 40, No. 11
0095-1137/02/$04.00+0 DOI: 10.1128/JCM.40.11.4015-4020.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Loschen, S., Batzing-Feigenbaum, J., Poggensee, G., Cordes, C., Hintsche, B., Rausch, M., Dupke, S., Gohlke-Micknis, S., Rodig, J., Hamouda, O., Kucherer, C.
(2008). Comparison of the Human Immunodeficiency Virus (HIV) Type 1-Specific Immunoglobulin G Capture Enzyme-Linked Immunosorbent Assay and the Avidity Index Method for Identification of Recent HIV Infections. J. Clin. Microbiol.
46: 341-345
[Abstract]
[Full Text]
-
Chawla, A., Murphy, G., Donnelly, C., Booth, C. L., Johnson, M., Parry, J. V., Phillips, A., Geretti, A. M.
(2007). Human Immunodeficiency Virus (HIV) Antibody Avidity Testing To Identify Recent Infection in Newly Diagnosed HIV Type 1 (HIV-1)-Seropositive Persons Infected with Diverse HIV-1 Subtypes. J. Clin. Microbiol.
45: 415-420
[Abstract]
[Full Text]
-
Martro, E., Suligoi, B., Gonzalez, V., Bossi, V., Esteve, A., Mei, J., Ausina, V., and the Recent HIV Infections Study Group,
(2005). Comparison of the Avidity Index Method and the Serologic Testing Algorithm for Recent Human Immunodeficiency Virus (HIV) Seroconversion, Two Methods Using a Single Serum Sample for Identification of Recent HIV Infections. J. Clin. Microbiol.
43: 6197-6199
[Abstract]
[Full Text]
-
Barin, F., Meyer, L., Lancar, R., Deveau, C., Gharib, M., Laporte, A., Desenclos, J.-C., Costagliola, D.
(2005). Development and Validation of an Immunoassay for Identification of Recent Human Immunodeficiency Virus Type 1 Infections and Its Use on Dried Serum Spots. J. Clin. Microbiol.
43: 4441-4447
[Abstract]
[Full Text]
-
Soroka, S. D., Granade, T. C., Candal, D., Parekh, B. S.
(2005). Modification of Rapid Human Immunodeficiency Virus (HIV) Antibody Assay Protocols for Detecting Recent HIV Seroconversion. CVI
12: 918-921
[Abstract]
[Full Text]
-
de Freitas Oliveira, C. A., Ueda, M., Yamashiro, R., Rodrigues, R., Sheppard, H. W., de Macedo Brigido, L. F.
(2005). Rate and Incidence Estimates of Recent Human Immunodeficiency Virus Type 1 Infections among Pregnant Women in Sao Paulo, Brazil, from 1991 to 2002. J. Clin. Microbiol.
43: 1439-1442
[Abstract]
[Full Text]
-
Puchhammer-Stockl, E., Schmied, B., Rieger, A., Sarcletti, M., Geit, M., Zangerle, R., Hofmann, H.
(2005). Low Proportion of Recent Human Immunodeficiency Virus (HIV) Infections among Newly Diagnosed Cases of HIV Infection as Shown by the Presence of HIV-Specific Antibodies of Low Avidity. J. Clin. Microbiol.
43: 497-498
[Abstract]
[Full Text]
Copyright © 2002 by the American Society for Microbiology. All rights reserved.