JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suligoi, B.
Right arrow Articles by Rezza, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suligoi, B.
Right arrow Articles by Rezza, G.
Journal of Clinical Microbiology, November 2002, p. 4015-4020, Vol. 40, No. 11
0095-1137/02/$04.00+0     DOI: 10.1128/JCM.40.11.4015-4020.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.

Precision and Accuracy of a Procedure for Detecting Recent Human Immunodeficiency Virus Infections by Calculating the Antibody Avidity Index by an Automated Immunoassay-Based Method

Barbara Suligoi,1* Claudio Galli,2 Mario Massi,3 Fiorella Di Sora,4 Mauro Sciandra,5 Patrizio Pezzotti,1 Olga Recchia,3 Francesco Montella,4 Alessandro Sinicco,5 and Giovanni Rezza1

Reparto AIDS e MST, Istituto Superiore di Sanità,1 Scientific Affairs, Abbott Diagnostics Division,2 Patologia Clinica,3 Clinic of Infectious Diseases, Ospedale S. Giovanni-Addolorata, Rome,4 Clinic of Infectious Diseases, Università di Torino, Turin, Italy5

Received 18 April 2002/ Returned for modification 6 June 2002/ Accepted 31 July 2002

We evaluated the precision and accuracy of a procedure for detecting recent human immunodeficiency virus (HIV) infections, specifically, the avidity index (AI) calculated using a method based on an automated AxSYM HIV 1/2gO assay (Abbott). To evaluate precision, we performed multiple replicates on eight HIV-positive serum samples. To evaluate the accuracy in identifying recent infections (i.e., within 6 months of seroconversion), we used 216 serum samples from 47 persons whose dates of seroconversion were known. To evaluate the sensitivity and specificity of the procedure for different AI cutoff values, we performed receiver operating characteristic (ROC) analysis. To determine the effects of antiretroviral treatment, advanced stage of the disease (i.e., low CD4-cell count), and low HIV viral load on the AI, we analyzed 15 serum samples from 15 persons whose dates of seroconversion were unknown. The precision study showed that the procedure was robust (i.e., the total variance of the AI was lower than 10%). Regarding accuracy, the mean AI was significantly lower for samples collected within 6 months of seroconversion, compared to those collected afterwards (0.68 ± 0.16 versus 0.99 ± 0.10; P < 0.0001), with no overlap of the 95% confidence intervals. The ROC analysis revealed that an AI lower than 0.6 had a sensitivity of 33.3% and a specificity of 98.4%, compared to 87.9 and 86.3%, respectively, for an AI lower than 0.9. Antiretroviral treatment, low CD4-cell count, and low viral load had no apparent effect on the AI. In conclusion, this procedure is reproducible and accurate in identifying recent infections; it is automated, inexpensive, and easy to perform, and it provides a quantitative result with different levels of sensitivity and specificity depending on the selected cutoff.


* Corresponding author. Mailing address: Reparto AIDS e MST, Istituto Superiore di Sanità, V.le Regina Elena 299, 00161 Rome, Italy. Phone: (39) 06 4938 7209. Fax: (39) 06 4938 7210. E-mail: suligoi{at}iss.it.


Journal of Clinical Microbiology, November 2002, p. 4015-4020, Vol. 40, No. 11
0095-1137/02/$04.00+0     DOI: 10.1128/JCM.40.11.4015-4020.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 2002 by the American Society for Microbiology. All rights reserved.