JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stelzl, E.
Right arrow Articles by Kessler, H. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stelzl, E.
Right arrow Articles by Kessler, H. H.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, April 2002, p. 1447-1450, Vol. 40, No. 4
0095-1137/02/$04.00+0     DOI: 10.1128/JCM.40.4.1447-1450.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.

Evaluation of an Automated Sample Preparation Protocol for Quantitative Detection of Hepatitis C Virus RNA

Evelyn Stelzl,1 Andrea Kormann-Klement,1 Josef Haas,2 Elisabeth Daghofer,1 Brigitte I. Santner,1 Egon Marth,1 and Harald H. Kessler1*

Molecular Diagnostics Laboratory, Institute of Hygiene, Karl-Franzens-University Graz, A-8010 Graz,1 Biometry Unit, Department of Obstetrics and Gynecology, Karl-Franzens-University Graz, A-8036 Graz, Austria2

Received 23 October 2001/ Returned for modification 24 December 2001/ Accepted 20 January 2002

The COBAS AMPLIPREP instrument for automated sample preparation has recently been introduced. In this study, the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test, which includes this new molecular device, was evaluated and compared to the COBAS AMPLICOR HCV MONITOR test, which includes a manual extraction protocol. Interassay and intra-assay variation, precision, and linearity were determined, and a total of 130 clinical specimens were investigated. For determination of interassay variation, coefficients of variation were found to be between 9 and 59% for the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and between 13 and 69% for the COBAS AMPLICOR HCV MONITOR test. For determination of intra-assay variation, coefficients of variation were found to be between 7 and 13% for the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and between 8 and 16% for the COBAS AMPLICOR HCV MONITOR test. When precision of the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test was tested, all results were found to be within ±0.5 log of the expected results. Determination of linearity resulted in a quasilinear curve over 3 logs. When clinical samples were tested with the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and compared with the COBAS AMPLICOR HCV MONITOR test, all results were found within ±0.5 log. In conclusion, the assay, which included the new molecular device, proved to be suitable for the routine molecular laboratory. It was found to be laborsaving and easy to handle.


* Corresponding author. Mailing address: Molecular Diagnostics Laboratory, Institute of Hygiene, KF-University Graz, Universitaetsplatz 4, A-8010 Graz, Austria. Phone: 43 (316) 380-7717. Fax: 43(316) 380-9649. E-mail: harald.kessler{at}uni-graz.at.


Journal of Clinical Microbiology, April 2002, p. 1447-1450, Vol. 40, No. 4
0095-1137/02/$04.00+0     DOI: 10.1128/JCM.40.4.1447-1450.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 2002 by the American Society for Microbiology. All rights reserved.