This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Richter, S. S.
Right arrow Articles by Doern, G. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Richter, S. S.
Right arrow Articles by Doern, G. V.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, July 2002, p. 2437-2444, Vol. 40, No. 7
0095-1137/02/$04.00+0     DOI: 10.1128/JCM.40.7.2437-2444.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.

Minimizing the Workup of Blood Culture Contaminants: Implementation and Evaluation of a Laboratory-Based Algorithm

S. S. Richter,* S. E. Beekmann, J. L. Croco, D. J. Diekema, F. P. Koontz, M. A. Pfaller, and G. V. Doern

Medical Microbiology Division, Department of Pathology, University of Iowa College of Medicine, Iowa City, Iowa

Received 5 November 2001/ Returned for modification 4 December 2001/ Accepted 16 April 2002

An algorithm was implemented in the clinical microbiology laboratory to assess the clinical significance of organisms that are often considered contaminants (coagulase-negative staphylococci, aerobic and anaerobic diphtheroids, Micrococcus spp., Bacillus spp., and viridans group streptococci) when isolated from blood cultures. From 25 August 1999 through 30 April 2000, 12,374 blood cultures were submitted to the University of Iowa Clinical Microbiology Laboratory. Potential contaminants were recovered from 495 of 1,040 positive blood cultures. If one or more additional blood cultures were obtained within ±48 h and all were negative, the isolate was considered a contaminant. Antimicrobial susceptibility testing (AST) of these probable contaminants was not performed unless requested. If no additional blood cultures were submitted or there were additional positive blood cultures (within ±48 h), a pathology resident gathered patient clinical information and made a judgment regarding the isolate's significance. To evaluate the accuracy of these algorithm-based assignments, a nurse epidemiologist in approximately 60% of the cases performed a retrospective chart review. Agreement between the findings of the retrospective chart review and the automatic classification of the isolates with additional negative blood cultures as probable contaminants occurred among 85.8% of 225 isolates. In response to physician requests, AST had been performed on 15 of the 32 isolates with additional negative cultures considered significant by retrospective chart review. Agreement of pathology resident assignment with the retrospective chart review occurred among 74.6% of 71 isolates. The laboratory-based algorithm provided an acceptably accurate means for assessing the clinical significance of potential contaminants recovered from blood cultures.


* Corresponding author. Mailing address: Department of Pathology, C606 GH, University of Iowa College of Medicine, Iowa City, IA 52242. Phone: (319) 356-2990. Fax: (319) 356-4916. E-mail: sandra-richter{at}uiowa.edu.


Journal of Clinical Microbiology, July 2002, p. 2437-2444, Vol. 40, No. 7
0095-1137/02/$04.00+0     DOI: 10.1128/JCM.40.7.2437-2444.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Huang, D. T., Angus, D. C., Kellum, J. A., Pugh, N. A., Weissfeld, L. A., Struck, J., Delude, R. L., Rosengart, M. R., Yealy, D. M. (2009). Midregional Proadrenomedullin as a Prognostic Tool in Community-Acquired Pneumonia. Chest 136: 823-831 [Abstract] [Full Text]  
  • Muldrew, K. L., Tang, Y.-W., Li, H., Stratton, C. W. (2008). Clonal Dissemination of Staphylococcus epidermidis in an Oncology Ward. J. Clin. Microbiol. 46: 3391-3396 [Abstract] [Full Text]  
  • Qamruddin, A, Khanna, N, Orr, D (2008). Peripheral blood culture contamination in adults and venepuncture technique: prospective cohort study. J. Clin. Pathol. 61: 509-513 [Abstract] [Full Text]  
  • Forrest, G. N., Mehta, S., Weekes, E., Lincalis, D. P., Johnson, J. K., Venezia, R. A. (2006). Impact of rapid in situ hybridization testing on coagulase-negative staphylococci positive blood cultures. J Antimicrob Chemother 58: 154-158 [Abstract] [Full Text]  
  • Varettas, K., Mukerjee, C., Taylor, P. C. (2005). Anticoagulant Carryover May Influence Clot Formation in Direct Tube Coagulase Tests from Blood Cultures. J. Clin. Microbiol. 43: 4613-4615 [Abstract] [Full Text]  
  • Schelenz, S, Page, A J F, Emmerson, A M (2005). Streptococcus mutans endocarditis: beware of the 'diphtheroid'. JRSM 98: 420-421 [Full Text]  
  • Chapin, K. C., Musgnug, M. C. (2003). Direct Susceptibility Testing of Positive Blood Cultures by Using Sensititre Broth Microdilution Plates. J. Clin. Microbiol. 41: 4751-4754 [Abstract] [Full Text]  
  • Chapin, K., Musgnug, M. (2003). Evaluation of Three Rapid Methods for the Direct Identification of Staphylococcus aureus from Positive Blood Cultures. J. Clin. Microbiol. 41: 4324-4327 [Abstract] [Full Text]  
  • Weinstein, M. P. (2003). Blood Culture Contamination: Persisting Problems and Partial Progress. J. Clin. Microbiol. 41: 2275-2278 [Full Text]