JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reina, J.
Right arrow Articles by Mari, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reina, J.
Right arrow Articles by Mari, M.
Journal of Clinical Microbiology, September 2002, p. 3515-3517, Vol. 40, No. 9
0095-1137/02/$04.00+0     DOI: 10.1128/JCM.40.9.3515-3517.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.

Evaluation of a New Dot Blot Enzyme Immunoassay (Directigen Flu A+B) for Simultaneous and Differential Detection of Influenza A and B Virus Antigens from Respiratory Samples

Jordi Reina,* Emma Padilla, Fermin Alonso, Enrique Ruiz de Gopegui, Maria Munar, and Margarita Mari

Virology Unit, Clinical Microbiology Service, University Hospital Son Dureta (Universitat Illes Balears), 07014 Palma de Mallorca, Spain

Received 5 February 2002/ Returned for modification 20 March 2002/ Accepted 24 May 2002

We report a prospective evaluation of a new dot blot enzyme immunoassay (EIA) method for the direct, rapid, qualitative, simultaneous, and differential detection of the influenza A (IA) and B (IB) virus antigen in different respiratory samples. The EIA method was compared with the shell vial culture system (MDCK cell line) used with the same samples. We studied 160 samples from 93 (58.1%) pediatric patients (hospital emergency room) and from 67 (41.9%) adult patients (sentinel network). Seventy-four(46.2%) samples were considered positive; of them, 46 (62.2%) were from pediatric patients and 28 (37.8%) were from an adult group (P < 0.05), with overall positive values of 49.9% and 41.7%, respectively. All 74 (100%) of the positive samples were isolated in cell culture versus the 68.9% that were detected as positive by the new EIA method (P < 0.05). Of the 41 samples positive for the IA virus, the EIA detected 34 (82.9%) positive samples; of the 33 samples positive for the IB virus, the EIA detected 17 (51.5%) positive samples (P < 0.05). No false-positive reaction was detected with the EIA method (specificity and positive predictive value of 100%). The overall results obtained in the comparison between the new EIA and the shell vial culture had a sensibility of 82.9% and predictive negative values of 92.4% for the IA virus and 51.5% and 84.3%, respectively, for the IB virus. This evaluation shows sensitivity and specificity percentages for the new EIA method that is acceptable for routine use in IA virus detection. The results obtained were worse for IB virus detection, but this new EIA method is actually the only one with the capacity to differentiate between the two influenza viruses.


* Corresponding author. Mailing address: Virology Unit, Clinical Microbiology Service, University Hospital Son Dureta, Andrea Doria 55, 07014-Palma de Mallorca, Spain. E-mail: jreina{at}hsd.es.


Journal of Clinical Microbiology, September 2002, p. 3515-3517, Vol. 40, No. 9
0095-1137/02/$04.00+0     DOI: 10.1128/JCM.40.9.3515-3517.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 2002 by the American Society for Microbiology. All rights reserved.