This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weber, B.
Right arrow Articles by Rabenau, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weber, B.
Right arrow Articles by Rabenau, H.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, January 2003, p. 135-143, Vol. 41, No. 1
0095-1137/03/$08.00+0     DOI: 10.1128/JCM.41.1.135-143.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.

Evaluation of Two New Automated Assays for Hepatitis B Virus Surface Antigen (HBsAg) Detection: IMMULITE HBsAg and IMMULITE 2000 HBsAg

Bernard Weber,1,2* Thomas Dengler,3 Annemarie Berger,2 Hans Wilhelm Doerr,2 and Holger Rabenau2

Laboratoires Réunis Kutter-Lieners-Hastert, Junglinster, Luxembourg,1 Institut für Medizinische Virologie, Universitätsklinikum der Johann Wolfgang Goethe-Universität, Frankfurt am Main,2 Blutspendedienst, Baden-Baden, Germany3

Received 10 January 2002/ Returned for modification 18 May 2002/ Accepted 22 September 2002

In recent years the diagnostic industry has developed new automated immunoassays for the qualitative detection of hepatitis B virus (HBV) surface antigen (HBsAg) in serum and plasma samples that are performed on analyzers that permit a high-speed throughput, random access, and primary tube sampling. The aim of the present study was the evaluation of two new automated HBsAg screening assays, IMMULITE HBsAg and IMMULITE 2000 HBsAg, from Diagnostic Products Corporation. The new HBsAg assays were compared to well-established tests (Auszyme Monoclonal [overnight incubation, version B], IMx HBsAg, AxSYM HBsAg, and Prism HBsAg [all from Abbott] and Elecsys HBsAg [Roche Diagnostics]). In the evaluation were included seroconversion panels, sera from the acute and chronic phases of infection, dilution series of various HBsAg standards, HBV subtypes and S gene mutants. To challenge the specificity of the new assays, sera from HBsAg-negative blood donors, pregnant women, and dialysis and hospitalized patients and potentially cross-reactive samples were investigated. IMMULITE HBsAg and IMMULITE 2000 HBsAg, although not as sensitive as the Elecsys HBsAg assay, were equivalent to the AxSYM HBsAg assay and showed a higher sensitivity than the Auszyme Monoclonal B and IMx HBsAg systems for detection of acute infection in seroconversion panels. The specificities (100%) of both IMMULITE assays on unselected blood donors and potentially interfering samples were comparable to those of the alternative assays after repeated testing. In conclusion, the new IMMULITE HBsAg and IMMULITE 2000 HBsAg assays show a good sensitivity for HBsAg detection compared to other well-established tests. The specificity on repeatedly tested samples was equivalent to that of the alternative assays. The rapid turnaround time, primary tube sampling, and on-board dilution make it an interesting assay system for clinical laboratory diagnosis.


* Corresponding author. Mailing address: Laboratoires Réunis Kutter-Lieners-Hastert, Centre Langwies, L-6131 Junglinster, Luxembourg. Phone: (352) 7802901. Fax: (352) 788894. E-mail: web{at}labo.lu.


Journal of Clinical Microbiology, January 2003, p. 135-143, Vol. 41, No. 1
0095-1137/03/$08.00+0     DOI: 10.1128/JCM.41.1.135-143.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Chen, D., Kaplan, L. A. (2006). Performance of a New-Generation Chemiluminescent Assay for Hepatitis B Surface Antigen. Clin. Chem. 52: 1592-1598 [Abstract] [Full Text]  
  • Ollert, M., Weissenbacher, S., Rakoski, J., Ring, J. (2005). Allergen-Specific IgE Measured by a Continuous Random-Access Immunoanalyzer: Interassay Comparison and Agreement with Skin Testing. Clin. Chem. 51: 1241-1249 [Abstract] [Full Text]  
  • Che, X.-y., Qiu, L.-w., Pan, Y.-x., Wen, K., Hao, W., Zhang, L.-y., Wang, Y.-d., Liao, Z.-y., Hua, X., Cheng, V. C. C., Yuen, K.-y. (2004). Sensitive and Specific Monoclonal Antibody-Based Capture Enzyme Immunoassay for Detection of Nucleocapsid Antigen in Sera from Patients with Severe Acute Respiratory Syndrome. J. Clin. Microbiol. 42: 2629-2635 [Abstract] [Full Text]