JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bourbeau, P. P.
Right arrow Articles by Heiter, B. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bourbeau, P. P.
Right arrow Articles by Heiter, B. J.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, June 2003, p. 2686-2689, Vol. 41, No. 6
0095-1137/03/$08.00+0     DOI: 10.1128/JCM.41.6.2686-2689.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.

Evaluation of Copan Swabs with Liquid Transport Media for Use in the Gen-Probe Group A Strep Direct Test

Paul P. Bourbeau* and Barbara J. Heiter

Division of Laboratory Medicine, Geisinger Medical Center, Danville, Pennsylvania

Received 9 January 2003/ Returned for modification 13 February 2003/ Accepted 27 February 2003

The Gen-Probe Group A Streptococcus Direct Test (GASDT), which detects the presence or absence of group A streptococci directly from pharyngeal specimens, utilizes a specific relative light unit (RLU) cutoff of 4,500 to differentiate between positive and negative test results. In response to a report by a manufacturer that the background RLU values for the Copan rayon swabs with liquid media were higher than the RLU values typically observed with Culturette swabs, we tested multiple lots of Copan rayon swabs with liquid media and determined that the swabs are unacceptable for routine use in the GASDT. The high background RLU values for the Copan rayon swabs appear to be a direct result of the gamma irradiation used to sterilize the swabs. We also performed a comparative clinical evaluation of Copan Dacron swabs with liquid media and Culturette swabs for use in the GASDT. Overall, there was 97.5% agreement between the results obtained with the Copan Dacron swabs and those obtained with the Culturette swabs. Compared to Culturette swabs, the Copan Dacron swabs had a sensitivity and a specificity of 97 and 98%, respectively. Copan Dacron swabs with liquid media are an acceptable alternative to the swabs currently qualified for use with the GASDT, but Copan rayon swabs with liquid transport media should not be used in the GASDT.


* Corresponding author. Mailing address: Division of Laboratory Medicine, Geisinger Medical Center, Danville, PA 17822-0131. Phone: (570) 271-7467. Fax: (570) 271-6105. E-mail: pbourbeau{at}geisinger.edu.


Journal of Clinical Microbiology, June 2003, p. 2686-2689, Vol. 41, No. 6
0095-1137/03/$08.00+0     DOI: 10.1128/JCM.41.6.2686-2689.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.