Previous Article | Next Article 
Journal of Clinical Microbiology, January 2004, p. 16-20, Vol. 42, No. 1
0095-1137/04/$08.00+0 DOI: 10.1128/JCM.42.1.16-20.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
Simple DNA Extraction Method for Dried Blood Spots and Comparison of Two PCR Assays for Diagnosis of Vertical Human Immunodeficiency Virus Type 1 Transmission in Rwanda
A. Fischer,1* C. Lejczak,1 C. Lambert,1 J. Servais,2 N. Makombe,2 J. Rusine,2 T. Staub,3 R. Hemmer,1,3 F. Schneider,1,4 J. C. Schmit,1,3 and V. Arendt1,3
Retrovirology Laboratory, CRP-Santé,1
National Service of Infectious Diseases,3
Centre Hospitalier de Luxembourg, Laboratoire National de Santé, Luxembourg,4
Treatment and Research AIDS Center, Kigali, Rwanda2
Received 4 April 2003/
Returned for modification 10 July 2003/
Accepted 27 September 2003
Dried blood spots (DBS) on filter paper facilitate the collection, transport, and storage of blood samples for laboratory use. A rapid and simple DNA extraction procedure from DBS was developed and evaluated for the diagnosis of human immunodeficiency virus type 1 (HIV-1) infection in children by an in-house nested-PCR assay on three genome regions and by the Amplicor HIV-1 DNA prototype assay version 1.5 (Roche Molecular Systems). A total of 150 samples from children born to HIV-1-infected mothers were collected in Kigali, Rwanda, in parallel as DBS and as peripheral blood mononuclear cell (PBMC) pellets. The results obtained on DBS by the two PCR assays were compared to the results of nested PCR on PBMCs. Of 150 PBMC samples, 10 were positive, 117 were negative, and 23 were indeterminate for HIV-1 infection. In DNA extracted from filter papers and amplified by using the in-house nested PCR, 9 of these 10 positive samples (90%) were found to be positive, and 1 was found to be indeterminate (only the pol region could be amplified). All of the negative samples and all of the 23 indeterminate samples tested negative for HIV-1 infection. When we used the Amplicor DNA test on DBS, all of the 10 PBMC-positive samples were found to be positive and all of the 23 indeterminate samples were found to be negative. Of the PBMC-negative samples, 115 were found to be negative and 2 were found to be indeterminate. We conclude that this simple rapid DNA extraction method on DBS in combination with both detection methods gave a reliable molecular diagnosis of HIV-1 infection in children born to HIV-infected mothers.
* Corresponding author. Mailing address: Retrovirology Laboratory, Centre Hospitalier de Luxembourg, Clinique Pédiatrique, 2ème Étage, L-1210 Luxembourg. Phone: (352) 44-11-61-12. Fax: (352) 44-11-61-13. E-mail: fischer.a{at}retrovirology.lu.
Journal of Clinical Microbiology, January 2004, p. 16-20, Vol. 42, No. 1
0095-1137/04/$08.00+0 DOI: 10.1128/JCM.42.1.16-20.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Khamadi, S., Okoth, V., Lihana, R., Nabwera, J., Hungu, J., Okoth, F., Lubano, K., Mwau, M.
(2008). Rapid Identification of Infants for Antiretroviral Therapy in a Resource Poor Setting: The Kenya Experience. J Trop Pediatr
0: fmn036v1-fmn036
[Abstract]
[Full Text]
-
Zhang, Q., Wang, L., Jiang, Y., Fang, L., Pan, P., Gong, S., Yao, J., Tang, Y.-W., Vermund, S. H., Jia, Y.
(2008). Early Infant Human Immunodeficiency Virus Type 1 Detection Suitable for Resource-Limited Settings with Multiple Circulating Subtypes by Use of Nested Three-Monoplex DNA PCR and Dried Blood Spots. J. Clin. Microbiol.
46: 721-726
[Abstract]
[Full Text]
-
Steegen, K., Luchters, S., Demecheleer, E., Dauwe, K., Mandaliya, K., Jaoko, W., Plum, J., Temmerman, M., Verhofstede, C.
(2007). Feasibility of Detecting Human Immunodeficiency Virus Type 1 Drug Resistance in DNA Extracted from Whole Blood or Dried Blood Spots. J. Clin. Microbiol.
45: 3342-3351
[Abstract]
[Full Text]
-
Patton, J. C., Akkers, E., Coovadia, A. H., Meyers, T. M., Stevens, W. S., Sherman, G. G.
(2007). Evaluation of Dried Whole Blood Spots Obtained by Heel or Finger Stick as an Alternative to Venous Blood for Diagnosis of Human Immunodeficiency Virus Type 1 Infection in Vertically Exposed Infants in the Routine Diagnostic Laboratory. CVI
14: 201-203
[Abstract]
[Full Text]
-
Gasasira, A. F., Dorsey, G., Kamya, M. R., Havlir, D., Kiggundu, M., Rosenthal, P. J., Charlebois, E. D.
(2006). False-positive results of enzyme immunoassays for human immunodeficiency virus in patients with uncomplicated malaria.. J. Clin. Microbiol.
44: 3021-3024
[Abstract]
[Full Text]
-
Luo, W., Yang, H., Rathbun, K., Pau, C.-P., Ou, C.-Y.
(2005). Detection of Human Immunodeficiency Virus Type 1 DNA in Dried Blood Spots by a Duplex Real-Time PCR Assay. J. Clin. Microbiol.
43: 1851-1857
[Abstract]
[Full Text]
-
GUZMAN, H., DING, X., XIAO, S.-Y., TESH, R. B.
(2005). DURATION OF INFECTIVITY AND RNA OF VENEZUELAN EQUINE ENCEPHALITIS, WEST NILE, AND YELLOW FEVER VIRUSES DRIED ON FILTER PAPER AND MAINTAINED AT ROOM TEMPERATURE. Am J Trop Med Hyg
72: 474-477
[Abstract]
[Full Text]
Copyright © 2004 by the American Society for Microbiology. All rights reserved.