This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Caliendo, A. M.
Right arrow Articles by Easley, K. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Caliendo, A. M.
Right arrow Articles by Easley, K. A.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, November 2004, p. 5392-5393, Vol. 42, No. 11
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.11.5392-5393.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.

Comparison of the Sensitivities and Viral Load Values of the AMPLICOR HIV-1 MONITOR Version 1.0 and 1.5 Tests

Angela M. Caliendo,1* Jessica Ingersoll,1 Alicia M. Green,1 Frederick S. Nolte,1 and Kirk A. Easley2

Department of Pathology and Laboratory Medicine, School of Medicine,1 Biostatistics, Rollins School of Public Health, Emory University, Atlanta, Georgia2

Received 26 March 2004/ Returned for modification 14 June 2004/ Accepted 11 August 2004

This study compared the sensitivity and viral load values of the AMPLICOR HIV-1 MONITOR microwell version 1.0, microwell version 1.5, and COBAS version 1.5 tests. Based on the percentage of positive replicates, the microwell version 1.5 and COBAS version 1.5 tests are more sensitive than the microwell version 1.0 test. Viral load values obtained with the COBAS version 1.5 test are lower than those obtained with either the microwell version 1.0 or microwell version 1.5 test.


* Corresponding author. Mailing address: Clinical Laboratories, H180, Emory University Hospital, 1364 Clifton Rd., NE, Atlanta, GA 30322. Phone: (404) 712-5721. Fax: (404) 712-3133. E-mail: acalien{at}emory.edu.


Journal of Clinical Microbiology, November 2004, p. 5392-5393, Vol. 42, No. 11
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.11.5392-5393.2004