This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fujimoto, T.
Right arrow Articles by Nishio, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fujimoto, T.
Right arrow Articles by Nishio, O.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, December 2004, p. 5489-5492, Vol. 42, No. 12
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.12.5489-5492.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.

Evaluation of a Bedside Immunochromatographic Test for Detection of Adenovirus in Respiratory Samples, by Comparison to Virus Isolation, PCR, and Real-Time PCR

Tsuguto Fujimoto,1* Teruo Okafuji,2 Takao Okafuji,2 Masahiro Ito,3 Soichi Nukuzuma,3 Masatsugu Chikahira,1 and Osamu Nishio4

Infectious Disease Research Division, Hyogo Prefectural Institute of Public Health and Environmental Sciences,1 Kobe Institute of Health, Kobe,3 Okafuji Pediatric Clinic, Himeji,2 National Institute of Infectious Diseases, Musashi-murayama, Tokyo, Japan4

Received 27 May 2004/ Returned for modification 9 July 2004/ Accepted 24 August 2004

An immunochromatography (IC) kit for human adenovirus (HAdV) was evaluated with 138 patient nasopharyngeal samples. The samples were collected at a sentinel clinic in Japan from January through June 2003. Patients were diagnosed by clinical manifestation of pharyngoconjunctival fever (n = 38) or exudative tonsillitis (n = 100). The IC kit was positive for 84% (116 of 138) of patients diagnosed at bedside. The remaining extract solution of the IC kit test was transferred into maintenance medium and tested via laboratory diagnoses. The IC kit had 95% sensitivity (116 of 122 patients) with HAdV isolation (isolation) as the standard and 91% sensitivity (116 of 128 patients) with PCR as the standard. All of the IC kit-positive samples were isolation and PCR positive. Similarly, all the isolation-positive samples were PCR positive. Twenty-two IC kit-negative samples were evaluated by real-time PCR. Six samples were IC kit negative and isolation positive and contained 3.8 x 107 to 2.5 x 109 copies of the HAdV genome/ml. Five samples that were only PCR positive contained 3.0 x 104 to 3.8 x 105 copies of the HAdV genome/ml, but one sample was real-time PCR negative. We conclude that the IC kit is a useful bedside diagnostic tool for HAdV infections because it has 95% sensitivity (compared to isolation), but a negative result does not always rule out HAdV infection.


* Corresponding author. Mailing address: Infectious Disease Research Division, Hyogo Prefectural Institute of Public Health and Environmental Sciences, 2-1-29, Arata-Cho, Hyogo-Ku, Kobe 652-0032, Japan. Phone: 81-78-511-6640, ext. 236. Fax: 81-78-531-7080. E-mail: Tsuguto_Fujimoto{at}pref.hyogo.jp.


Journal of Clinical Microbiology, December 2004, p. 5489-5492, Vol. 42, No. 12
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.12.5489-5492.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Echavarria, M. (2008). Adenoviruses in Immunocompromised Hosts. Clin. Microbiol. Rev. 21: 704-715 [Abstract] [Full Text]