JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stelzl, E.
Right arrow Articles by Kessler, H. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stelzl, E.
Right arrow Articles by Kessler, H. H.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, June 2004, p. 2445-2449, Vol. 42, No. 6
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.6.2445-2449.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.

Rapid Quantification of Hepatitis B Virus DNA by Automated Sample Preparation and Real-Time PCR

Evelyn Stelzl,1 Zsofia Muller,2 Egon Marth,1 and Harald H. Kessler1*

Molecular Diagnostics Laboratory, Institute of Hygiene, Medical University Graz, A-8010 Graz, Austria,1 Microbiological Laboratory, Regional Public Health Center, H-8000 Szekesfehervar, Hungary2

Received 12 November 2003/ Returned for modification 12 January 2004/ Accepted 3 March 2004

Monitoring of hepatitis B virus (HBV) DNA in serum by molecular methods has become the standard for assessment of the replicative activity of HBV. Several molecular assays for the detection and quantification of HBV DNA have been described. However, they usually lack automated sample preparation. Moreover, those assays, which are based on PCR, are limited by a short dynamic range (2 to 3 log units). In the present study, the use of RealArt HBV LC PCR Reagents in conjunction with automated extraction on the COBAS AMPLIPREP analyzer was evaluated. Members of an HBV proficiency program panel were tested; linearity, interassay, and intra-assay variations were determined. The performance of the assay in a routine clinical laboratory was evaluated with a total of 117 clinical specimens. When members of the HBV proficiency program panel were tested by the new molecular assay, the results were found to be within ±0.5 log unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve over more than 6 log units. The interassay variation of the RealArt HBV LC PCR Reagents by use of the automated sample preparation protocol ranged from 16 to 73%, and the intra-assay variation ranged from 9 to 40%. When clinical samples were tested by the new assay with the automated sample preparation protocol and the results were compared with those obtained by the COBAS AMPLICOR HBV MONITOR Test with manual sample preparation, the results for 76% of all samples with positive results by both tests were found to be within ±0.5 log unit and the results for another 18% were found to be within between 0.5 and 1.0 log unit. In conclusion, the real-time PCR assay with automated sample preparation proved to be suitable for the routine molecular laboratory and required less hands-on time.


* Corresponding author. Mailing address: Molecular Diagnostics Laboratory, Institute of Hygiene, Medical University Graz, Universitaetsplatz 4, A-8010 Graz, Austria. Phone: 43(316)380-7717. Fax: 43(316)380-9649. E-mail: harald.kessler{at}meduni-graz.at.


Journal of Clinical Microbiology, June 2004, p. 2445-2449, Vol. 42, No. 6
0095-1137/04/$08.00+0     DOI: 10.1128/JCM.42.6.2445-2449.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 2004 by the American Society for Microbiology. All rights reserved.