Previous Article | Next Article ![]()
Journal of Clinical Microbiology, August 2004, p. 3813-3815, Vol. 42, No. 8
0095-1137/04/$08.00+0 DOI: 10.1128/JCM.42.8.3813-3815.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
Division of Infectious Diseases,1 Division of Oncology, University Children's Hospital of Zurich, CH-8032 Zurich,2 Institute of Medical Microbiology, University of Berne, CH-3010 Berne, Switzerland3
Received 22 January 2004/ Returned for modification 24 February 2004/ Accepted 30 April 2004
A real-time PCR assay targeting the capsulation locus of Haemophilus influenzae type b (Hib) was developed. The linear detection range was from 1 to 106 microorganisms per reaction mixture. No H. influenzae other than Hib or any other control bacteria typically found in the upper respiratory tract was detected.
This article has been cited by other articles:
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»