This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kato, H.
Right arrow Articles by Arakawa, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kato, H.
Right arrow Articles by Arakawa, Y.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, December 2005, p. 6108-6112, Vol. 43, No. 12
0095-1137/05/$08.00+0     doi:10.1128/JCM.43.12.6108-6112.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.

Rapid and Simple Method for Detecting the Toxin B Gene of Clostridium difficile in Stool Specimens by Loop-Mediated Isothermal Amplification

Haru Kato,1* Toshiyuki Yokoyama,2 Hideaki Kato,3 and Yoshichika Arakawa1

Department of Bacterial Pathogenesis and Infection Control, National Institute of Infectious Diseases,1 Kumiai Kosei Hospital, Gifu,2 Toyokawa City Hospital, Aichi Japan3

Received 3 June 2005/ Returned for modification 12 August 2005/ Accepted 3 October 2005

We applied the loop-mediated isothermal amplification (LAMP) assay to the detection of the toxin B gene (tcdB) of Clostridium difficile for identification of toxin B (TcdB)-positive C. difficile strains and detection of tcdB in stool specimens. tcdB was detected in all toxin A (TcdA)-positive, TcdB-positive (A+B+) and TcdA-negative, TcdB-positive (AB+) C. difficile strains but not from TcdA-negative, TcdB-negative strains. Of the 74 stool specimens examined, A+B+ or AB+ C. difficile was recovered from 39 specimens, of which 38 specimens were LAMP positive and one was negative. Amplification was obtained in 10 specimens that were culture negative, indicating that LAMP is highly sensitive. The LAMP assay was applied to detection of tcdB in DNA extracted by a simple boiling method from 47 of those 74 specimens, which were cultured overnight in cooked-meat medium (CMM). Twenty-two of 24 culture-positive specimens were positive for LAMP on DNA from the culture in CMM. Four specimens were culture negative but positive by LAMP on DNA from CMM cultures. The LAMP assay is a reliable tool for identification of TcdB-positive C. difficile as well as for direct detection of tcdB in stool specimens with high sensitivity. Detection of tcdB by LAMP from overnight cultures in CMM could be an alternative method of diagnostic testing at clinical laboratories without special apparatus.


* Corresponding author. Mailing address: Department of Bacterial Pathogenesis and Infection Control, National Institute of Infectious Diseases, 4-7-1 Musashimurayama,Tokyo 208-0011, Japan. Phone: 81-42-561-0771. Fax: 81-42-561-7173. E-mail: cato{at}nih.go.jp.


Journal of Clinical Microbiology, December 2005, p. 6108-6112, Vol. 43, No. 12
0095-1137/05/$08.00+0     doi:10.1128/JCM.43.12.6108-6112.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Inacio, J., Flores, O., Spencer-Martins, I. (2008). Efficient Identification of Clinically Relevant Candida Yeast Species by Use of an Assay Combining Panfungal Loop-Mediated Isothermal DNA Amplification with Hybridization to Species-Specific Oligonucleotide Probes. J. Clin. Microbiol. 46: 713-720 [Abstract] [Full Text]  
  • Sekiguchi, J.-I., Asagi, T., Miyoshi-Akiyama, T., Kasai, A., Mizuguchi, Y., Araake, M., Fujino, T., Kikuchi, H., Sasaki, S., Watari, H., Kojima, T., Miki, H., Kanemitsu, K., Kunishima, H., Kikuchi, Y., Kaku, M., Yoshikura, H., Kuratsuji, T., Kirikae, T. (2007). Outbreaks of Multidrug-Resistant Pseudomonas aeruginosa in Community Hospitals in Japan. J. Clin. Microbiol. 45: 979-989 [Abstract] [Full Text]  
  • Kamachi, K., Toyoizumi-Ajisaka, H., Toda, K., Soeung, S. C., Sarath, S., Nareth, Y., Horiuchi, Y., Kojima, K., Takahashi, M., Arakawa, Y. (2006). Development and Evaluation of a Loop-Mediated Isothermal Amplification Method for Rapid Diagnosis of Bordetella pertussis Infection.. J. Clin. Microbiol. 44: 1899-1902 [Abstract] [Full Text]