Institut für Mikrobiologie und Hygiene, Campus Charité Mitte, CharitéUniversitätsmedizin Berlin ,1 Institut für Medizinische Mikrobiologie am HELIOS-Klinikum Berlin-Buch, HAEMA AG Berlin, Germany2
Received 2 August 2004/ Returned for modification 10 September 2004/ Accepted 5 December 2004
Commercially available nucleic acid probe- and amplification-based systems for detection and differentiation of mycobacteria are widely used in clinical microbiology laboratories. Here we report two cases of human leprosy in which the COBAS AMPLICOR Mycobacterium intracellulare test led to false- positive results. Correct identification of Mycobacterium leprae was possible only by amplification and comparative sequence analysis of the 16S rRNA gene.