This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ribault, S.
Right arrow Articles by Faure, I. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ribault, S.
Right arrow Articles by Faure, I. B.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, May 2005, p. 2251-2255, Vol. 43, No. 5
0095-1137/05/$08.00+0     doi:10.1128/JCM.43.5.2251-2255.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.

Detection of Bacteria in Red Blood Cell Concentrates by the Scansystem Method

S. Ribault,* A. Faucon, L. Grave, P. Nannini, and I. Besson Faure

Hemosystem, 45 cours Gouffé, 13006 Marseille, France

Received 26 November 2004/ Returned for modification 24 December 2004/ Accepted 17 January 2005

Bacterial contamination remains one of the major risks associated with blood product transfusion. The kinetics of bacterial growth in red blood cell concentrates (RBCC) is different than otherwise due to storage at 4°C, conditions in which most bacteria do not survive. Psychrophilic bacteria such as Yersinia enterocolitica, however, can proliferate from a very low level of contamination to clinically significant levels at 4°C and are known to cause severe transfusion-related infections. A screening method allowing the early detection of very low levels of bacteria in RBCC would improve transfusion safety. The Scansystem method has been previously described for detection of bacteria in platelet concentrates. We present here a modification of the system for detection of low levels of bacteria in RBCC. The Scansystem RBC kit protocol requires three steps, i.e., the agglutination and selective removal of RBCs, a labeling stage during which bacteria are labeled with a DNA-specific fluorophore, and finally recovery of bacteria on the surface of a black membrane for analysis using the Scansystem. The entire procedure from sampling to result can be completed in 90 min. Both gram-negative and gram-positive bacteria in RBCC are detected with a higher sensitivity than with currently available culture-based methods. The Scansystem RBC kit is shown to be sensitive enough to identify low-level bacterial contamination in a single unit tested in a pool of up to 20 RBCC samples (detection limit of between 1 and 10 CFU/ml depending on the bacterial strain). The method therefore lends itself to incorporation into high-sample-throughput screening programs.


* Corresponding author. Mailing address: Hemosystem, 45 cours Gouffé, 13006 Marseille, France. Phone: 33 (0) 4 96 20 29 77. Fax: 33 (0) 4 96 20 29 99. E-mail: sebribault{at}hemosystem.com.


Journal of Clinical Microbiology, May 2005, p. 2251-2255, Vol. 43, No. 5