JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Li, C.-C.
Right arrow Articles by Frenkel, L. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Li, C.-C.
Right arrow Articles by Frenkel, L. M.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, August 2005, p. 3901-3905, Vol. 43, No. 8
0095-1137/05/$08.00+0     doi:10.1128/JCM.43.8.3901-3905.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.

Detection and Quantification of Human Immunodeficiency Virus Type 1 p24 Antigen in Dried Whole Blood and Plasma on Filter Paper Stored under Various Conditions

Chung-Chen Li,1,2 Kristy D. Seidel,3 Robert W. Coombs,4,5 and Lisa M. Frenkel1,4*

Departments of Pediatrics,1 Laboratory Medicine,4 Medicine, University of Washington,5 Department of Biostatistics, Children's Hospital and Regional Medical Center, Seattle, Washington,3 Departments of Pediatrics, Chang-Gang Children's Hospital, Kaohsiung, Taiwan2

Received 18 March 2005/ Accepted 6 May 2005

The quantification of human immunodeficiency virus type 1 (HIV-1) by an assay measuring heat-dissociated (HD) p24 antigen (Ag) in specimens of whole blood and plasma stored on filter paper, and of plasma stored in tubes, was compared to HIV-1 RNA plasma levels determined by real-time reverse transcription (RT)-PCR. The stability of p24 Ag on filter paper under conditions simulating specimen transport was also evaluated. The HD p24 Ag in both plasma and whole-blood specimens stored on filter paper correlated with plasma HIV-1 RNA levels (Spearman rank {rho} = 0.74 [P < 0.0001] and {rho} = 0.56 [P = 0.0001], respectively). The sensitivity of the HD p24 Ag assay was similar when plasma and whole blood on filter paper were contrasted to the real-time RT-PCR assay (80% versus 82.5% and 78.6% versus 83.3%, respectively). However, while the specificity of the HD p24 Ag assay of plasma on filter paper was 100%, the specificity was diminished in whole-blood specimens. The storage of specimens on filter paper for 2 weeks at 37°C, 24°C, or 0°C did not alter the detection or quantification of HD p24 Ag. These results suggest that transport and storage of plasma on filter paper and quantification of HD p24 Ag may be a reliable method for HIV-1 load monitoring.


* Corresponding author. Mailing address: 307 Westlake Avenue North, Suite 300, Room 330, Seattle, WA 98105. Phone: (206) 987-5140. Fax: (206) 987-7311. E-mail: lfrenkel{at}u.washington.edu.


Journal of Clinical Microbiology, August 2005, p. 3901-3905, Vol. 43, No. 8
0095-1137/05/$08.00+0     doi:10.1128/JCM.43.8.3901-3905.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 2005 by the American Society for Microbiology. All rights reserved.