JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dreier, J.
Right arrow Articles by Kleesiek, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dreier, J.
Right arrow Articles by Kleesiek, K.
Journal of Clinical Microbiology, September 2005, p. 4551-4557, Vol. 43, No. 9
0095-1137/05/$08.00+0     doi:10.1128/JCM.43.9.4551-4557.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.

Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays

Jens Dreier,* Melanie Störmer, and Knut Kleesiek

Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Bad Oeynhausen, Germany

Received 1 February 2005/ Returned for modification 11 April 2005/ Accepted 18 June 2005

Diagnostic systems based on reverse transcription (RT)-PCR are widely used for the detection of viral genomes in different human specimens. The application of internal controls (IC) to monitor each step of nucleic acid amplification is necessary to prevent false-negative results due to inhibition or human error. In this study, we designed various real-time RT-PCRs utilizing the coliphage MS2 replicase gene, which differ in detection format, amplicon size, and efficiency of amplification. These noncompetitive IC assays, using TaqMan, hybridization probe, or duplex scorpion probe techniques, were tested on the LightCycler and Rotorgene systems. In our approach, clinical specimens were spiked with the control virus to monitor the efficiency of extraction, reverse transcription, and amplification steps. The MS2 RT-PCR assays were applied for internal control when using a second target hepatitis C virus RNA in duplex PCR in blood donor screening. The 95% detection limit was calculated by probit analysis to 44.9 copies per PCR (range, 38.4 to 73.4). As demonstrated routinely, application of MS2 IC assays exhibits low variability and can be applied in various RT-PCR assays. MS2 phage lysates were obtained under standard laboratory conditions. The quantification of phage and template RNA was performed by plating assays to determine PFU or via real-time RT-PCR. High stability of the MS2 phage preparations stored at –20°C, 4°C, and room temperature was demonstrated.


* Corresponding author. Mailing address: Institut für Laboratoriums- und Transfusionsmedizin, Herz- und Diabeteszentrum Nordrhein-Westfalen, Universitätsklinik der Ruhr-Universität Bochum, Georgstrasse 11, D-32545 Bad Oeynhausen, Germany. Phone: 49-5731-97 1390. Fax: 49-5731-97 2307. E-mail: jdreier{at}hdz-nrw.de.


Journal of Clinical Microbiology, September 2005, p. 4551-4557, Vol. 43, No. 9
0095-1137/05/$08.00+0     doi:10.1128/JCM.43.9.4551-4557.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.