JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pai, R.
Right arrow Articles by Beall, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pai, R.
Right arrow Articles by Beall, B.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, January 2006, p. 124-131, Vol. 44, No. 1
0095-1137/06/$08.00+0     doi:10.1128/JCM.44.1.124-131.2006

Sequential Multiplex PCR Approach for Determining Capsular Serotypes of Streptococcus pneumoniae Isolates

Rekha Pai, Robert E. Gertz, and Bernard Beall*

Respiratory Diseases Branch, Division of Bacterial and Mycotic Diseases, Centers for Disease Control and Prevention, Atlanta, Georgia

Received 12 August 2005/ Returned for modification 20 September 2005/ Accepted 13 October 2005

Accurate serotyping is essential to monitor the changes in the seroepidemiology of Streptococcus pneumoniae. We devised a simple and schematic sequence-based system of seven multiplex PCRs, in a sequence order based upon Active Bacterial Core surveillance (ABCs) serotype distribution during 2002 to 2003, to reliably deduce specific pneumococcal serotypes. A total of 421 isolates from ABCs were randomly chosen to evaluate this system. Two hundred twenty-nine of the isolates (54.3%) were specifically assigned 1 of 17 serotypes by the multiplex PCR system, with the results in complete concordance with conventional serotyping. One hundred seventy-two additional isolates (40.9%) were assigned to 11 specific sets of 2 to 4 serotypes that with one exception (serotypes 6A and 6B) consisted of the single frequently occurring targeted serotype and 1 to 3 additional rare serotypes primarily within the same serogroup as the targeted serotype. Only 20 isolates (4.8%) could not be assigned specific serotypes or serotype sets, since they were either of rare serotypes not included in the assay design or were nonserotypeable. Overall, we found this system to be highly reliable, with the potential to greatly reduce our reliance upon conventional serotyping. Especially important is the capability of this system to give serotype-determining potential to any facility that lacks the expensive typing sera and expertise needed for conventional serotyping yet has the modest equipment necessary for DNA amplification and electrophoresis.


* Corresponding author. Mailing address: CDC Respiratory Diseases Branch, Mail Stop C02, 1600 Clifton Rd., NE, Atlanta, GA 30333. Phone: (404) 639-1237. Fax: (404) 639-4215. E-mail: BBEALL{at}CDC.GOV.


Journal of Clinical Microbiology, January 2006, p. 124-131, Vol. 44, No. 1
0095-1137/06/$08.00+0     doi:10.1128/JCM.44.1.124-131.2006