This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sautter, R. L.
Right arrow Articles by Bourbeau, P. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sautter, R. L.
Right arrow Articles by Bourbeau, P. P.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, April 2006, p. 1245-1249, Vol. 44, No. 4
0095-1137/06/$08.00+0     doi:10.1128/JCM.44.4.1245-1249.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.

Effects of Delayed-Entry Conditions on the Recovery and Detection of Microorganisms from BacT/ALERT and BACTEC Blood Culture Bottles

R. L. Sautter,1,{dagger} A. R. Bills,1 D. L. Lang,1 G. Ruschell,1 B. J. Heiter,2 and P. P. Bourbeau2*

Pinnacle Health Laboratories, Harrisburg,1 Geisinger Medical Center, Danville, Pennsylvania2

Received 14 November 2005/ Returned for modification 23 December 2005/ Accepted 11 January 2006

Manufacturers generally recommend that blood culture bottles be loaded into instruments within a short time of collection. However, in our experience, delays often occur prior to loading the bottles. We examined the effect of holding bottles under various temperatures (T)—room temperature (RT), 4°C, 37°C, and RT for 2 h following incubation at 37°C (to simulate transit [TR])—and for various holding times of 4, 12, and 24 h. We utilized the BacT/ALERT system with FA and FN bottles and the BACTEC system with Plus (PL) and Lytic 10 (LY) bottles. Standardized inocula and 5 ml of blood were added to each bottle. Fifteen organisms were evaluated based upon expected performance: aerobic (FA and PL), anaerobic (FN and LY 10), and facultative (all bottles). Based upon expected performance, the FA and FN bottles recovered 458 of 468 organisms and 282 of 288 organisms, respectively, whereas the PL and LY bottles recovered 453 of 468 organisms and 257 of 288 organisms, respectively (P = <0.001, FN versus LY). There were 3, 11, 21, and 27 false-negative results for bottles held at 4°C, RT, 37°C, and TR, respectively. There were 4, 8, and 50 false-negative results for bottles held for 4, 12, and 24 h, respectively. Our results support holding these four bottle types at 4°C or at RT for up to 24 h and at 37°C for up to 12 h. We propose that manufacturers only need to make claims for "delayed entry" when these bottles are held for more than 24 h at 4°C or at RT or for more than 12 h at 37°C.


* Corresponding author. Mailing address: Division of Laboratory Medicine, Geisinger Medical Center, Danville, PA 17822-0131. Phone: (570) 271-7467. Fax: (570) 271-6105. E-mail: pbourbeau{at}geisinger.edu.

{dagger} Present address: Carolinas Pathology Group, Carolina Medical Center, P.O. Box 34455, Charlotte, NC 28234-4455.


Journal of Clinical Microbiology, April 2006, p. 1245-1249, Vol. 44, No. 4
0095-1137/06/$08.00+0     doi:10.1128/JCM.44.4.1245-1249.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Kerremans, J. J., van der Bij, A. K., Goessens, W., Verbrugh, H. A., Vos, M. C. (2009). Immediate Incubation of Blood Cultures Outside Routine Laboratory Hours of Operation Accelerates Antibiotic Switching. J. Clin. Microbiol. 47: 3520-3523 [Abstract] [Full Text]  
  • Zhao, Y., Park, S., Kreiswirth, B. N., Ginocchio, C. C., Veyret, R., Laayoun, A., Troesch, A., Perlin, D. S. (2009). Rapid Real-Time Nucleic Acid Sequence-Based Amplification-Molecular Beacon Platform To Detect Fungal and Bacterial Bloodstream Infections. J. Clin. Microbiol. 47: 2067-2078 [Abstract] [Full Text]