This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Garcia-Diaz, A.
Right arrow Articles by Geretti, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Garcia-Diaz, A.
Right arrow Articles by Geretti, A. M.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, May 2006, p. 1788-1791, Vol. 44, No. 5
0095-1137/06/$08.00+0     doi:10.1128/JCM.44.5.1788-1791.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.

Comparative Evaluation of the Performance of the Abbott Real-Time Human Immunodeficiency Virus Type 1 (HIV-1) Assay for Measurement of HIV-1 Plasma Viral Load following Automated Specimen Preparation

A. Garcia-Diaz, G. S. Clewley, C. L. Booth, W. Labett, N. McAllister, and A. M. Geretti*

Department of Virology, Royal Free Hospital and Royal Free and University College Medical School, London, United Kingdom

Received 27 October 2005/ Returned for modification 7 December 2005/ Accepted 13 February 2006

The performance of the new Abbott real-time human immunodeficiency virus type 1 (HIV-1) assay for HIV-1 RNA load determination in plasma was compared to that of the Abbott LCx HIV-1 RNA quantitative assay following automated RNA isolation by the Abbott m1000 extractor. The measured viral loads of 89 clinical specimens differed by mean 0.19 log10 copies/ml (95% confidence interval, 0.12 to 0.26 log10 copies/ml). Although the difference in viral load determinations was positively skewed in favor of the LCx assay, it did not reach statistical significance (P = 0.42). Results were linearly associated (R2 = 0.94) and strongly correlated (R = 0.96). Good performance was observed with HIV-1 subtypes other than B and circulating recombinant forms, although results obtained with two subtype G specimens and one H specimen showed a more substantial difference.


* Corresponding author. Mailing address: Department of Virology, Royal Free Hospital and Royal Free and University College Medical School, Royal Free Hospital, Pond Street, London NW3 2PF, United Kingdom. Phone: 44-20 77940500. Fax: 44-20 7830 2854. E-mail: a.geretti{at}medsch.ucl.ac.uk.


Journal of Clinical Microbiology, May 2006, p. 1788-1791, Vol. 44, No. 5
0095-1137/06/$08.00+0     doi:10.1128/JCM.44.5.1788-1791.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Labbett, W., Garcia-Diaz, A., Fox, Z., Clewley, G. S., Fernandez, T., Johnson, M., Geretti, A. M. (2009). Comparative Evaluation of the ExaVir Load Version 3 Reverse Transcriptase Assay for Measurement of Human Immunodeficiency Virus Type 1 Plasma Load. J. Clin. Microbiol. 47: 3266-3270 [Abstract] [Full Text]  
  • Scott, L. E., Noble, L. D., Moloi, J., Erasmus, L., Venter, W. D. F., Stevens, W. (2009). Evaluation of the Abbott m2000 RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay for HIV Load Monitoring in South Africa Compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 Assays. J. Clin. Microbiol. 47: 2209-2217 [Abstract] [Full Text]  
  • Garrido, C., Zahonero, N., Corral, A., Arredondo, M., Soriano, V., de Mendoza, C. (2009). Correlation between Human Immunodeficiency Virus Type 1 (HIV-1) RNA Measurements Obtained with Dried Blood Spots and Those Obtained with Plasma by Use of Nuclisens EasyQ HIV-1 and Abbott RealTime HIV Load Tests. J. Clin. Microbiol. 47: 1031-1036 [Abstract] [Full Text]  
  • Garcia-Diaz, A., Blok, C., Madge, S., Booth, C., Tyrer, M., Bonora, S., Mahungu, T., Owen, A., Johnson, M., Geretti, A. M. (2008). Detection of low-frequency K103N mutants after unstructured discontinuation of efavirenz in the presence of the CYP2B6 516 TT polymorphism. J Antimicrob Chemother 62: 1188-1190 [Abstract] [Full Text]  
  • Schutten, M., Peters, D., Back, N. K. T., Beld, M., Beuselinck, K., Foulongne, V., Geretti, A.-M., Pandiani, L., Tiemann, C., Niesters, H. G. M. (2007). Multicenter Evaluation of the New Abbott RealTime Assays for Quantitative Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA. J. Clin. Microbiol. 45: 1712-1717 [Abstract] [Full Text]