Previous Article | Next Article ![]()
Journal of Clinical Microbiology, January 2007, p. 246-247, Vol. 45, No. 1
0095-1137/07/$08.00+0 doi:10.1128/JCM.01403-06
Copyright © 2007, American Society for Microbiology. All Rights Reserved.

National Reference Laboratory for HIV/AIDS, Hepatitis, and other STDs, STD/AIDS Cooperative Central Laboratory, Manila, Philippines
Received 7 July 2006/ Returned for modification 21 August 2006/ Accepted 18 October 2006
We evaluated four recent antibody-detection kits for typhoid fever by using 177 febrile patients from our hospital, in 75 of whom Salmonella enterica serotype Typhi grew. TUBEX performed best, achieving 94.7% sensitivity and 80.4% specificity. Typhidot, SD Bioline Typhoid, and Mega Salmonella were less specific and, in most cases, less sensitive.
Published ahead of print on 25 October 2006.
This article has been cited by other articles: