This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Damond, F.
Right arrow Articles by Descamps, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Damond, F.
Right arrow Articles by Descamps, D.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, October 2007, p. 3436-3438, Vol. 45, No. 10
0095-1137/07/$08.00+0     doi:10.1128/JCM.00973-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.

Human Immunodeficiency Virus Type 1 (HIV-1) Plasma Load Discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR Version 1.5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Assays{triangledown}

F. Damond,1* B. Roquebert,1 A. Bénard,2 G. Collin,1 M. Miceli,1 P. Yéni,3 F. Brun-Vezinet,1 and D. Descamps1

Laboratoire de Virologie, Hôpital Bichat Claude Bernard, Paris, France,1 INSERM U593, ISPED Bordeaux F33076, France,2 Service Maladies Tropicales et Infectieuses, Hopital Bichat Claude Bernard, Paris, France3

Received 10 May 2007/ Returned for modification 11 July 2007/ Accepted 27 July 2007

We compared plasma viral load values obtained with COBAS AMPLICOR human immunodeficiency virus type 1 (HIV-1) MONITOR version 1.5 and with COBAS TaqMan HIV-1 assays. Mean values were 4.2 and 2.9 log10 copies/ml, respectively, showing the lack of agreement between the two assays.


* Corresponding author. Mailing address: Laboratoire de Virologie, Hôpital Bichat Claude Bernard, 75018 Paris, France. Phone: 33 1 40 25 61 51. Fax: 33 1 40 25 67 69. E-mail: florence.damond{at}bch.aphp.fr

{triangledown} Published ahead of print on 22 August 2007.


Journal of Clinical Microbiology, October 2007, p. 3436-3438, Vol. 45, No. 10
0095-1137/07/$08.00+0     doi:10.1128/JCM.00973-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Scott, L. E., Noble, L. D., Moloi, J., Erasmus, L., Venter, W. D. F., Stevens, W. (2009). Evaluation of the Abbott m2000 RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay for HIV Load Monitoring in South Africa Compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 Assays. J. Clin. Microbiol. 47: 2209-2217 [Abstract] [Full Text]  
  • Wirden, M., Tubiana, R., Marguet, F., Leroy, I., Simon, A., Bonmarchand, M., Ait-Arkoub, Z., Murphy, R., Marcelin, A. G., Katlama, C., Calvez, V. (2009). Impact of Discrepancies between the Abbott RealTime and Cobas TaqMan Assays for Quantification of Human Immunodeficiency Virus Type 1 Group M Non-B Subtypes. J. Clin. Microbiol. 47: 1543-1545 [Abstract] [Full Text]  
  • Sloma, C. R., Germer, J. J., Gerads, T. M., Mandrekar, J. N., Mitchell, P. S., Yao, J. D. C. (2009). Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test: Workflow, Reliability, and Direct Costs. J. Clin. Microbiol. 47: 889-895 [Abstract] [Full Text]  
  • Korn, K., Weissbrich, B., Henke-Gendo, C., Heim, A., Jauer, C. M., Taylor, N., Eberle, J. (2009). Single-Point Mutations Causing More than 100-Fold Underestimation of Human Immunodeficiency Virus Type 1 (HIV-1) Load with the Cobas TaqMan HIV-1 Real-Time PCR Assay. J. Clin. Microbiol. 47: 1238-1240 [Abstract] [Full Text]  
  • Holguin, A., Lopez, M., Molinero, M., Soriano, V. (2008). Performance of Three Commercial Viral Load Assays, Versant Human Immunodeficiency Virus Type 1 (HIV-1) RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2, Testing HIV-1 Non-B Subtypes and Recombinant Variants. J. Clin. Microbiol. 46: 2918-2923 [Abstract] [Full Text]  
  • Yao, J. D. C., Germer, J. J., Damond, F., Roquebert, B., Descamps, D. (2008). Plasma Load Discrepancies between the Roche Cobas Amplicor Human Immunodeficiency Virus Type 1 (HIV-1) Monitor Version 1.5 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Assays. J. Clin. Microbiol. 46: 834-834 [Full Text]