JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Other Versions of this Article:
JCM.01762-07v1
46/2/488    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Google Scholar
Right arrow Articles by Esteban, J.
Right arrow Articles by Fernandez-Roblas, R.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Esteban, J.
Right arrow Articles by Fernandez-Roblas, R.
Journal of Clinical Microbiology, February 2008, p. 488-492, Vol. 46, No. 2
0095-1137/08/$08.00+0     doi:10.1128/JCM.01762-07
Copyright © 2008, American Society for Microbiology. All Rights Reserved.

Evaluation of Quantitative Analysis of Cultures from Sonicated Retrieved Orthopedic Implants in Diagnosis of Orthopedic Infection{triangledown}

Jaime Esteban,1* Enrique Gomez-Barrena,2 Jose Cordero,3 Nieves Zamora Martín-de-Hijas,1 Teemu J. Kinnari,1 and Ricardo Fernandez-Roblas1

Departments of Clinical Microbiology,1 Orthopaedic Surgery, Fundación Jiménez Díaz-UTE, Universidad Autónoma de Madrid, Madrid, Spain,2 Department of Orthopaedic Surgery, Hospital la Princesa, Universidad Autónoma de Madrid, Madrid, Spain3

Received 5 September 2007/ Returned for modification 16 October 2007/ Accepted 28 November 2007

To improve the microbiological diagnosis of device-related osteoarticular infections, we have developed a protocol based on the sonication of device samples, followed by concentration and inoculation of the sonicate in a broad variety of media in a quantitative manner. Sixty-six samples from 31 patients were included in the study (17 of them with clinical diagnosis of infection). The sonication procedure had a sensitivity of 94.1%, which is better than that of conventional cultures (88.2%). One case of contamination and six cases of unexpected positive cultures were detected (specificity of 42.8%): two of these were considered to represent true infection, while the other four were considered to be nonsignificant (corrected specificity of 50%), although the clinical importance of these isolates is questionable. When we analyzed the number of CFU, no breakpoint between significant and nonsignificant isolates could be established. Based on our results, the procedure of sonication of retrieved implants is better than conventional cultures for the diagnosis of device-related infections. The significance of some isolates in patients without clinical infection remains uncertain. However, they may become pathogens and cannot be routinely considered to be contamination.


* Corresponding author. Mailing address: Department of Clinical Microbiology, Fundación Jiménez Díaz-UTE, Av. Reyes Católicos 2, 28040 Madrid, Spain. Phone: 34 915504800. Fax: 34 915494764. E-mail: jesteban{at}fjd.es

{triangledown} Published ahead of print on 12 December 2007.


Journal of Clinical Microbiology, February 2008, p. 488-492, Vol. 46, No. 2
0095-1137/08/$08.00+0     doi:10.1128/JCM.01762-07