This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Google Scholar
Right arrow Articles by Beloukas, A.
Right arrow Articles by Hatzakis, A.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beloukas, A.
Right arrow Articles by Hatzakis, A.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, July 2009, p. 2194-2199, Vol. 47, No. 7
0095-1137/09/$08.00+0     doi:10.1128/JCM.01264-08
Copyright © 2009, American Society for Microbiology. All Rights Reserved.

Development and Assessment of a Multiplex Real-Time PCR Assay for Quantification of Human Immunodeficiency Virus Type 1 DNA{triangledown}

A. Beloukas,{dagger} D. Paraskevis,{dagger} C. Haida, V. Sypsa, and A. Hatzakis*

Department of Hygiene, Epidemiology and Medical Statistics, Medical School, University of Athens, Athens, Greece

Received 4 July 2008/ Returned for modification 17 January 2009/ Accepted 27 April 2009

Previous studies showed that high levels of human immunodeficiency virus type 1 (HIV-1) DNA are associated with a faster progression to AIDS, an increased risk of death, and a higher risk of HIV RNA rebound in patients on highly active antiretroviral therapy. Our objective was to develop and assess a highly sensitive real-time multiplex PCR assay for the quantification of HIV-1 DNA (RTMP-HIV) based on molecular beacons. HIV-1 DNA quantification was carried out by RTMP in a LightCycler 2.0 apparatus. HIV-1 DNA was quantified in parallel with CCR5 as a reference gene, and reported values are numbers of HIV-1 DNA copies/106 peripheral blood mononuclear cells (PBMCs). The clinical sensitivity of the assay was assessed for 115 newly diagnosed HIV-1-infected individuals. The analytical sensitivity was estimated to be 12.5 copies of HIV-1 DNA per 106 PBMCs, while the clinical sensitivity was 100%, with levels ranging from 1.23 to 4.25 log10 HIV-1 DNA copies/106 PBMCs. In conclusion, we developed and assessed a new RTMP-HIV assay based on molecular beacons, using a LightCycler 2.0 instrument. This multiplex assay has comparable sensitivity, reproducibility, and accuracy to single real-time PCR assays.


* Corresponding author. Mailing address: Department of Hygiene, Epidemiology and Medical Statistics, Medical School, University of Athens, M. Asias 75, GR-115 27 Athens, Greece. Phone: (30210) 7462090. Fax: (30210) 7462190. E-mail: ahatzak{at}med.uoa.gr

{triangledown} Published ahead of print on 6 May 2009.

{dagger} The first two authors contributed equally to this work.


Journal of Clinical Microbiology, July 2009, p. 2194-2199, Vol. 47, No. 7
0095-1137/09/$08.00+0     doi:10.1128/JCM.01264-08
Copyright © 2009, American Society for Microbiology. All Rights Reserved.