JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suksanong, M
Right arrow Articles by Dajani, A S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suksanong, M
Right arrow Articles by Dajani, A S

 Previous Article  |  Next Article 

J Clin Microbiol. 1977 January; 5(1): 81-85

Detection of Haemophilus influenzae type b antigens in body fluids, using specific antibody-coated staphylococci.

M Suksanong and A S Dajani

ABSTRACT

Protein A-rich staphylococci coated with Haemophilus influenzae type b antiserum agglutinate specifically with homologous bacterial cells or with cell-free supernatant fluids of cultures of the organism. Antibody-coated staphylococci were used to detect soluble antigens in body fluids of patients infected with H. influenzae type b. Cerebrospinal fluid from 36 cases of meningitis caused by this orgainsm showed positive coagglutination tests in 86% of patients prior to initiation of therapy. Antigens could be detected in 46% of sterile cerebrospinal fluid specimens obtained from the same cases 1 to 10 days after therapy. Soluble antigens were also detectable in sera (58%) and urine specimens (67%) of patients with H. influenzae type b septicemia, when such specimens were tested within 10 days of onset of illness. No antigen could be detected in body fluids beyond 10 days. The coagglutination test was positive in 57% of all body fluids examined; contercurrent immunoelectrophoresis (CCIE) was positive in only 27%. All specimens positive by CCIE were also positive by coagglutination. No false-positive reactions were noted by either test in body fluids from controls. The coagglutination test is simple, specific, and more sensitive than the CCIE method and could be a valuable tool for detecting antigens in body fluids of patients with various infections.


J Clin Microbiol. 1977 January; 5(1): 81-85







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1977 by the American Society for Microbiology. All rights reserved.