JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ryan, K J
Right arrow Articles by Mihalyi, S F
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ryan, K J
Right arrow Articles by Mihalyi, S F
J Clin Microbiol. 1977 February; 5(2): 178-183

Evaluation of a simple device for bacteriological sampling of respirator-generated aerosols.

K J Ryan and S F Mihalyi

ABSTRACT

The Aerotest sampler (Olympic Medical Corp., Seattle, Wash.) is designed to detect bacterial contamination of respirator-generated aerosols in a simple one-step process. The sampler was evaluated by controlled contamination of Bennett AP-5, PR-2, and MA-1 respirators with Escherichia coli, Pseudomonas aeruginosa, and Acinetobacter. Bacteria present as viable 1.4 to 3.5-mum particles in each of 77 aerosols were quantitated by using the Andersen viable-particle sampler, and the results were compared with those of colonies obtained from 10-s or 15-cycle Aerotest samples. All aerosols containing counts greater than expected in hospital air were detected by the Aerotest method. Thirteen of 14 aerosols containing less than 20 bacteria/0.028 m3 showed fewer than 5 colonies, whereas all aerosols containing greater than 1,000 bacteria/0.028 m3 showed at least 40 colonies. Aerosols with intermediate counts fell in between. Under the conditions described here, the Aerotest sampler was able to discriminate between the low levels of bacteria commonly found in hospital air and the bacterial contamination associated with nosocomial pneumonia. The Aerotest sampler provides a practical method for surveillance sampling of respirator nebulizers.


J Clin Microbiol. 1977 February; 5(2): 178-183







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1977 by the American Society for Microbiology. All rights reserved.