JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bishai, F R
Right arrow Articles by Galli, R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bishai, F R
Right arrow Articles by Galli, R
J Clin Microbiol. 1978 December; 8(6): 648-656

Enzyme-linked immunosorbent assay for detection of antibodies to influenza A and B and parainfluenza type 1 in sera of patients.

F R Bishai and R Galli

ABSTRACT

An enzyme-linked immunosorbent assay (ELISA) was developed for the detection of antibodies to influenza A/Hong Kong/1/68, influenza A/Victoria/3/75, influenza B/Hong Kong/5/72, and parainfluenza type 1 viruses. Development and standardization of the method indicated that an acetone-ethyl alcohol mixture was a suitable fixative for the preparation of the solid-phase coupled antigen. The addition of sodium azide to the enzyme-conjugated solution and the concentrations of the enzyme-conjugate antiglobulin and test sera employed were all critical factors in the success of the ELISA procedure. The ELISA test was specific; there was no cross-reaction between influenza A and B or parainfluenza type 1 viruses. The concordance between ELISA and hemagglutination inhibition results suggested that both tests probably detected the same type of antibodies. The ELISA procedure was 8 to 64 times more sensitive than complement fixation and/or hemagglutination inhibition tests. Low levels of antibody in patients' sera were detected only by the ELISA test. During the course of the testing period false positive reactions were not encountered. The results of ELISA could be obtained within 3 h. The ELISA test required a very small amount of serum and, therefore, offered an opportunity to detect the presence of maternal antibodies to influenza viruses in blood collected from infants by heel prick.


J Clin Microbiol. 1978 December; 8(6): 648-656




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1978 by the American Society for Microbiology. All rights reserved.