JCM Figure table search 04
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Friedman, M G
Right arrow Articles by Sarov, I
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Friedman, M G
Right arrow Articles by Sarov, I

Next Article 

J Clin Microbiol. 1979 January; 9(1): 1-10

Sensitive solid-phase radioimmunoassay for detection of human immunoglobulin G antibodies to varicella-zoster virus.

M G Friedman, S Leventon-Kriss and I Sarov

ABSTRACT

A sensitive solid-phase radioimmunoassay for detection of antibodies to varicella-zoster virus (VZV) is described. The antigen consisted of a sonically disrupted extract of VZV-infected human embryo cells. 125I-labeled rabbit anti-human immunoglobulin G (IgG) specific for the Fc portion of human IgG was used to detect human IgG bound to viral antigen. With this technique, 193 human sera were evaluated for their IgG antibody titer against ZVZ. Subjects included 62 healthy adults, 33 young children (12 healthy), and 49 patients. Titers obtained by the radioimmunoassay were compared with those obtained by indirect fluoresence antibody staining of membrane antigen. The radioimmunoassay technique described gave titers approximately 5 X 10(4) times higher than those shown by indirect fluorescence. It can be used for routine diagnosis, but is especially suited to determining immune status to VZV, as defined by presence or absence of antibodies to the virus; for epidemiological studies; or for determining patients at risk who are exposed to the virus. No heterotypic titer rises to VZV were observed in sera with fourfold or greater rises to Epstein-Barr virus or cytomegalovirus. Sera of eight subjects with fourfold or greater titer rises to herpes simplex virus reacted in various ways: in six cases no significant change occurred in titer to VZV; one had a significant decrease in titer by the radioimmunoassay; and one had a significant increase. Possible reasons for these titer changes are discussed.


J Clin Microbiol. 1979 January; 9(1): 1-10







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev.
Clin. Vaccine Immunol. ALL ASM JOURNALS

Copyright © 1979 by the American Society for Microbiology. All rights reserved.