Previous Article | Next Article ![]()
Journal of Clinical Microbiology, March 1998, p. 835-839, Vol. 36, No. 3
Division of Molecular Virology, Baylor College of Medicine,
Houston, Texas,1 and
Antiviral Clinical
Research Department, Bristol-Myers Squibb Pharmaceutical Research
Institute, Wallingford, Connecticut2
Received 23 June 1997/Returned for modification 7 November
1997/Accepted 1 December 1997
Three kits (Roche AMPLICOR human immunodeficiency virus type 1 [HIV-1] Monitor, Chiron enhanced-sensitivity bDNA, and Organon Teknika NASBA HIV-1 QT) and two in-house assays (from National Genetics
Institute and Baylor College of Medicine) were compared with a blinded
panel. The results were evaluated as to intra-assay sensitivity,
precision, and ability to detect differences in a dilution series.
The quantification in plasma of
human immunodeficiency virus type 1 (HIV-1) RNA is a useful test for
predicting clinical outcome, evaluating disease progression, and
monitoring the effect of antiretroviral treatment on HIV-1-infected
patients (6, 9). The primary reason for undertaking this
project was to evaluate the performance of selected methodologies or
laboratories for monitoring the effect of antiretroviral therapy on
HIV-1 viral load in clinical research. Three manufacturers of HIV-1 RNA
kits and an independent laboratory agreed to participate in a single
round of proficiency testing on a panel of plasma specimens. The
laboratories performing the tests were chosen by the manufacturers.
Enhanced-sensitivity bDNA assays (ES-bDNA) were performed at the Chiron
Reference Testing Laboratory (Emeryville, Calif.), Roche AMPLICOR
HIV-1 Monitor tests were carried out at Novum, Inc. (Pittsburgh, Pa.),
and NASBA (nucleic acid sequence-based amplification) HIV-1 QT assays
were performed at Advanced Bioscience Laboratories, Inc. (Kensington, Md.). National Genetics Institute, or NGI (Culver City, Calif.), an
established independent laboratory, used its in-house method. Because
the panel samples were prepared at the Center for AIDS Research
Virology Core Facility at Baylor College of Medicine (BCM), we have
also included in this report the results obtained with the in-house
method that was used to establish their nominal concentrations.
Summarized in Table 1 are the differences
among the five assays. The ES-bDNA assay for HIV-1 RNA is a
second-generation assay developed by the Chiron Corporation
(Emeryville, Calif.) and incorporates changes in probe design and
reagent composition (3). The distinctive feature of the NGI
in-house assay was the use of four different numbers of PCR cycles
(1). The AMPLICOR HIV-1 Monitor kit, manufactured by Roche
Molecular Systems (Branchburg, N.J.), employed Thermus
thermophilus polymerase, a recombinant enzyme capable of carrying
out both reverse transcription (RT) and PCR (7). Assays
based on NASBA technology developed by Organon Teknika (Durham, N.C.)
were carried out under isothermal conditions and resulted in an RNA
amplification product (11). The BCM method employed the
Qiagen viral RNA kit (Santa Clarita, Calif.) for sample preparation and
chemiluminescence assay of PCR products (Digene Diagnostics, Inc.,
Silver Spring, Md.) (5).
0095-1137/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.
Intra-Assay Performance Characteristics of Five
Assays for Quantification of Human Immunodeficiency Virus Type 1 RNA in Plasma
and
![]()
ABSTRACT
Top
Abstract
Text
References
![]()
TEXT
Top
Abstract
Text
References
TABLE 1.
Methods employed for quantification of HIV-1 RNA
HIV-1 standards and panel samples were prepared with normal acid-citrate-dextrose (ACD) plasma from individual blood donors who tested negative for anti-HIV-1, anti-HIV-2, anti-hepatitis B core, hepatitis B surface antigen, anti-hepatitis C virus, and anti-human T-cell leukemia virus type 1 (The Gulf Coast Regional Blood Center, Houston, Tex.). The primary standard was prepared by spiking negative plasma with supernatant fluid from a coculture of peripheral blood mononuclear cells from an HIV-1-infected patient (4). The secondary standard and panel samples were prepared by spiking negative plasma with HIV-1 strain HXB3 (5). Calibration of the secondary standards against the primary standard was based on 10 observations performed in five separate experiments with a between-runs coefficient of variation (CV) of 11.8%. The panel consisted of duplicate samples at 2.0 × 106, 1.0 × 106, 500,000, 130,000, and 65 HIV-1 RNA copies per ml; triplicate samples at 65,000, 13,000, 6,500, 1,300, 650, and 130 HIV-1 RNA copies per ml; and four samples of negative plasma. Aliquoting of samples was performed under optimal conditions to ensure sample uniformity. Specimens were shipped to testing sites on dry ice, and testing was performed in a blinded fashion at all sites, including the BCM laboratory.
Presented in Table 2 are the results of HIV-1 RNA quantification for each sample as reported by the testing sites, compared with the nominal HIV-1 RNA concentrations. In comparisons of those results that fell within the dynamic range claimed for each method (listed in a footnote to the table), the differences between the means of results for replicate samples that were obtained with the Chiron, NGI, BCM, and Roche assays generally fell within the same order of magnitude.
|
The data in Table 2 were evaluated with respect to the ability of the assays to detect the known differences in HIV-1 RNA concentration present in the dilution series (Fig. 1). Nominal and estimated HIV-1 RNA concentrations were expressed as logarithms to the base 10. For each method, the mean of the results for each group of two or three panel samples with the same nominal HIV-1 concentration was calculated and represented as a point in the appropriate panel in Fig. 1. Groups that contained results falling outside the claimed dynamic range were omitted. For example, the ES-bDNA assay results for the three samples with 500 nominal HIV-1 RNA copies per ml and two samples with nominal copy numbers of 2 × 106 were omitted. If an assay method correctly estimated the relationship of the various samples in the dilution series, a log-log plot of the estimated mean HIV-1 RNA concentrations against the nominal concentrations should produce a straight line having the same slope as the line of equivalence, shown in each panel as a diagonal straight line. The data set exhibiting the closest approximation of a straight line parallel to the line of equivalence was obtained by ES-bDNA. With perfect accuracy, the line representing the assay results should fall on the line of equivalence. This criterion must be applied with discretion, since the nominal concentrations of the panel samples are at best only estimates of an unknown value, the true HIV-1 RNA concentration. The results obtained with the Chiron, NGI, BCM, and Roche assays fell closest to the line of equivalence. These four assays provided estimates of HIV-1 RNA concentrations that generally agreed with each other and with the nominal concentrations of the BCM standards. In this sense, these assays were accurate. The slope of the line for the NASBA test also paralleled the line of equivalence but was displaced from it by approximately one log10.
|
The performance characteristics of the five assays are summarized in Table 3. The calculations of correlation, CV, and standard deviation (SD) were based solely on those results that fell within the claimed dynamic ranges. Correlation between the observed and nominal concentrations was close to 1.000 for all five assays, although the results obtained by the NASBA assay were consistently higher. Intra-assay precision was expressed by the CV and as the logarithm of the SD to the base 10 (log10 SD), a calculation that conveniently allowed comparison of SDs when the range of values covered several orders of magnitude. The ES-bDNA assay showed the smallest mean CV. An intra-assay SD of 0.15 to 0.20 log10 RNA copies per ml is required in order to achieve the degree of precision that will provide 90% power to detect a fivefold difference in RNA concentration between two samples (12). The ES-bDNA, NGI, and BCM assays achieved this degree of precision. The duplicate log10 SD was lower than the triplicate log10 SD for all methods. This result was attributable to the composition of the panel. Samples tested in duplicate were preponderantly those with high HIV-1 RNA concentrations, while samples tested in triplicate were those with lower concentrations. Of the five assays, the ES-bDNA assay showed the highest overall intra-assay precision, with a log10 SD of 0.050 to 0.054.
|
HIV-1-negative samples were correctly identified in all five assays, and no false positives were found; thus, the specificity was 100% for all five methods. It was demonstrated in the experiment shown in Fig. 1 that there was little or no difference between the nominal HIV-1 RNA concentrations and the estimates of HIV-1 RNA concentration obtained by the Chiron, NGI, BCM, and Roche methods. It was thus possible to compare the dynamic range claimed for each of these four methods to the observed lower and upper limits of detection, abbreviated L and U, respectively. The observed L for ES-bDNA was higher than the claimed L; the observed H was consistent with the claimed H. NGI's observed L and U exceeded its claimed dynamic range, while BCM's observed L and U were consistent with its claims. The observed L and U of the AMPLICOR HIV-1 Monitor were both lower than those claimed by the manufacturer.
This study underscores the importance of the use of well-defined standards for assigning nominal HIV-1 RNA concentrations to panel materials. In a previous comparison of the AMPLICOR HIV-1 Monitor and NASBA assays, both methods produced estimates below the nominal copy numbers (10). Compared to Monitor, NASBA has yielded higher estimates of HIV-1 RNA concentrations in two of three studies (2, 8, 10).
This article describes the first performance comparison of ES-bDNA with other assays for HIV-1 RNA. Among the five laboratories that used ES-bDNA, the NGI assay, the BCM assay, Roche HIV-1 Monitor, and NASBA HIV-1 QT, the laboratories performing the first four tests named provided results that were generally consistent with each other. However, interlaboratory variation with the same kit is known to occur and may be greater than that which occurs with different kits (12). In other evaluations, the NASBA assay has performed well (2, 8, 10). The reason for the approximately 10-fold-higher values provided by the NASBA assay in the present study is being investigated. This event appears to be isolated, since many laboratories have successfully adopted the NASBA method (12). In our opinion, the laboratory may be more important than the assay method in the selection of a testing site for clinical trials.
| |
ACKNOWLEDGMENTS |
|---|
We thank the following persons for their cooperation: John Todd and Pam Johnson, Chiron Corporation; Jay Weiss, Andrew J. Conrad, and Lawrence M. Blatt, NGI; Lisa Cosentino, Novum, Inc.; Beverly Dale, Roche Molecular Systems; Joe Romano, Advanced BioScience Laboratories, Inc.; and Michael Cronin, Stuart P. Geiger, and Richard J. Carroll, Organon Teknika Corp.
The primary standard for HIV-1 RNA was prepared in the Eugene B. Casey Hepatitis & HIV Research Center and Diagnostic Laboratory at BCM in connection with a study (4) supported by a National Institutes of Health grant (AI-82517). Additional support was provided by the Center for AIDS Research (CFAR) Virology Core Facility grant (P30 A136211-04/05) awarded to BCM.
| |
FOOTNOTES |
|---|
* Corresponding author. Mailing address: Division of Molecular Virology, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030. Phone: (713) 798-4454. Fax: (713) 798-3490. E-mail: blaineh{at}bcm.tmc.edu.
Present address: Glaxo Wellcome, Inc., Research Triangle Park,
NC 27709.
| |
REFERENCES |
|---|
|
|
|---|
| 1. | Conrad, A. J., P. Schmid, K. Syndulko, E. J. Singer, R. M. Nagra, J. J. Russell, and W. W. Tourtellotte. 1995. Quantifying HIV-1 RNA using the polymerase chain reaction on cerebrospinal fluid and serum of seropositive individuals with and without neurologic abnormalities. J. Acquired Immune Defic. Syndr. Hum. Retrovirol. 10:425-435[Medline]. |
| 2. | Coste, J., B. Montes, J. Reynes, M. Peeters, C. Segarra, J.-P. Vendrell, E. Delapporte, and M. Segondy. 1996. Comparative evaluation of three assays for the quantitation of human immunodeficiency virus type 1 RNA in plasma. J. Med. Virol. 50:293-302[Medline]. |
| 3. | Kern, D., M. Collins, T. Fultz, J. Detmer, S. Hamren, J. K. Peterkin, P. Sheridan, M. Urdea, R. White, T. Yeghiazarian, and J. Todd. 1996. An enhanced-sensitivity branched-DNA assay for quantification of human immunodeficiency virus type 1 RNA in plasma. J. Clin. Microbiol. 34:3196-3202[Abstract]. |
| 4. | Lin, H. J., L. E. Myers, B. Yen-Lieberman, F. B. Hollinger, D. Henrard, C. J. Hooper, R. Kokka, S. Kwok, S. Rasheed, M. Vahey, M. A. Winters, L. J. McQuay, P. L. Nara, P. Reichelderfer, R. W. Coombs, and J. B. Jackson. 1994. Multicenter evaluation of quantification methods for plasma human immunodeficiency virus type 1 RNA. J. Infect. Dis. 170:553-562[Medline]. |
| 5. | Lin, H. J., T. Tanwandee, and F. B. Hollinger. 1997. Improved methods for quantification of human immunodeficiency virus type 1 (HIV-1) RNA and hepatitis C virus (HCV) RNA in blood using spin column technology and chemiluminescent assays of PCR products. J. Med. Virol. 51:56-63[Medline]. |
| 6. | Mellors, J. W., C. R. Rinaldo, Jr., P. Gupta, R. M. White, J. A. Todd, and L. A. Kingsley. 1996. Prognosis in HIV-1 infection predicted by quantity of virus in plasma. Science 272:1167-1170[Abstract]. |
| 7. |
Mulder, J.,
N. McKinney,
C. Christopherson,
J. Sninsky,
L. Greenfield, and S. Kwok.
1994.
Rapid and simple PCR assay for quantitation of human immunodeficiency virus type 1 RNA in plasma: application to acute retroviral infection.
J. Clin. Microbiol.
32:292-300 |
| 8. | Revets, H., D. Marissens, S. De Wit, P. Lacor, N. Clumeck, S. Lauwers, and G. Zissis. 1996. Comparative evaluation of NASBA HIV-1 RNA QT, AMPLICOR-HIV Monitor, and QUANTIPLEX HIV RNA assay, three methods for quantification of human immunodeficiency virus type 1 RNA in plasma. J. Clin. Microbiol. 34:1058-1064[Abstract]. |
| 9. | Saag, M. S., M. Holodniy, D. R. Kuritzkes, W. A. O'Brien, R. Coombs, M. E. Poscher, D. M. Jacobsen, G. M. Shaw, D. D. Richman, and P. A. Volderbing. 1996. HIV viral load markers in clinical practice. Nat. Med. 2:625-629[Medline]. |
| 10. | Schuurman, R., D. Descamps, G. van Weverling, S. Kaye, J. Tijnagel, I. Williams, R. van Leeuwen, R. Tedder, C. A. Boucher, F. Brun-Vezinet, and C. Loveday. 1996. Multicenter comparison of three commercial methods for quantification of human immunodeficiency virus type 1 RNA in plasma. J. Clin. Microbiol. 34:3016-3022[Abstract]. |
| 11. | van Gemen, B., T. Kievits, R. Schukkink, D. van Strijp, L. T. Matek, R. Sooknanan, H. G. Huisman, and P. Lens. 1993. Quantification of HIV-1 RNA in plasma using NASBA during HIV-1 primary infection. J. Virol. Methods 43:177-188[Medline]. |
| 12. | Yen-Lieberman, B., D. Brambilla, B. Jackson, J. Bremer, R. Coombs, M. Cronin, S. Herman, D. Katzenstein, S. Leung, H. J. Lin, P. Palumbo, S. Rasheed, J. Todd, M. Vahey, and P. Reichelderfer. 1996. Evaluation of a quality assurance program for quantitation of human immunodeficiency virus type 1 RNA in plasma by the AIDS Clinical Trials Group Virology Laboratories. J. Clin. Microbiol. 34:2695-2701[Abstract]. |
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»