Previous Article | Next Article ![]()
Journal of Clinical Microbiology, May 1999, p. 1260-1264, Vol. 37, No. 5
Division of Infectious Diseases and Hospital
Epidemiology,
Received 28 August 1998/Returned for modification 9 December
1998/Accepted 26 January 1999
Precise and sensitive quantitation of viral RNA in specimens from
human immunodeficiency virus (HIV) type 1 (HIV-1)-infected individuals
has become an indispensable tool for the monitoring of the efficacy of
highly active antiretroviral combination therapy. The present report
describes reproducible and efficient protocols with enhanced
sensitivity for quantitation of HIV-1 RNA from plasma, peripheral blood
mononuclear cells, and tissues with Qiagen silica columns for RNA
purification combined with the Roche Amplicor HIV-1 Monitor test for
quantitative reverse transcription-PCR (RT-PCR). Extraction of RNA from
0.5 ml of plasma resulted in the detection of fewer than 20 HIV RNA
copies/ml of plasma, equivalent to the centrifugation-based boosted
RT-PCR assay. Silica extraction of cellular RNA resulted in the
detection of fewer than 3 HIV-1 RNA copies/µg of total RNA. These
techniques facilitate direct comparisons of viral loads between liquid
and cellular specimens. Application of these sensitive methods may
improve the assessment of the response to new antiretroviral regimens.
Highly active antiretroviral
combination therapy (HAART) frequently leads to undetectable viral
loads in plasma (3, 14). To evaluate new forms of therapy in
the research setting and to follow therapeutic efficacy in clinic
practice, increasingly sensitive diagnostic tests are needed. Reverse
transcription-PCR (RT-PCR) for the detection of human immunodeficiency
virus (HIV) RNA in plasma is widely used to monitor HIV type 1 (HIV-1)
levels (8). In particular, the ultrasensitive or boosted
Roche Amplicor HIV-1 Monitor test is among the most sensitive,
reproducible, and best-documented tools for the detection of low levels
of HIV-1 in plasma (7, 10). The boosted method represents a
modification of the original Amplicor test, in which the virus in
plasma is concentrated by centrifugation before RT-PCR, resulting in
detection limits in the range of 20 to 50 HIV-1 RNA copies per ml. This
test has become a new standard for the monitoring of patients receiving
HAART. In addition to providing a very sensitive means of detection of HIV-1 RNA, it can be performed in most well-equipped laboratories without additional equipment, and the use of commercially available reagents facilitates standardization.
Recent studies have shown that patients on long-term HAART can reach
such sustained viral suppression that their plasma virus loads drop
below the limit of detection of the boosted RT-PCR (<20 HIV-1 RNA
copies/ml) (4). Some investigators have turned to cellular
specimens, such as peripheral blood mononuclear cells (PBMCs) and
lymphoid tissue biopsy specimens, to monitor HIV transcription as a
marker for viral activity (2, 6, 9, 12, 13).
This report presents novel methods for the detection of HIV-1 RNA from
plasma, PBMCs, and tissue specimens. By using commercially available
solid silica columns for quantitative RNA extraction and the Amplicor
test for RT-PCR, highly sensitive and reproducible quantitation of
residual HIV-1 RNA can be achieved from plasma and cellular specimens.
Subjects and specimens.
Responses to combination
antiretroviral therapies (zidovudine [AZT] plus lamivudine [3TC] or
AZT plus 3TC plus ritonavir) were studied in subgroups of a larger
study population, including 44 HIV-1-infected, antiretroviral
agent-naive, asymptomatic patients attending the University of Zurich
Infectious Diseases Clinic. This project was approved by the University
Hospital Ethics Review Committee, and all subjects provided written
informed consent. Details of the study will be reported separately.
Extraction of RNA from plasma.
Two protocols were used for
extraction of RNA from plasma. The standard Amplicor protocol was
performed with the reagents included in the Amplicor HIV-1 Monitor test
kit (Roche Diagnostic Systems, Inc., Branchburg, N.J.), with the
following modifications. Instead of the recommended 0.2 ml of plasma,
0.15 ml of plasma was used as the starting volume so that the entire
procedure could be performed in 1.6-ml microtubes. The resulting
precipitate was dissolved in 0.3 ml of Amplicor specimen diluent
instead of the recommended 0.4 ml, to compensate for the decreased
plasma input volume. In addition, the plasma was mixed with 2 µl of
SeeDNA (Amersham, Little Chalfont, United Kingdom) before extraction to
better visualize the precipitate. The remainder of the procedure was
conducted as recommended by the manufacturer. These modifications improved the reproducibility and handling of the Amplicor HIV-1 Monitor
test without affecting other aspects of the test performance (unpublished observations).
0095-1137/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.
Highly Sensitive Methods for Quantitation of Human
Immunodeficiency Virus Type 1 RNA from Plasma, Cells, and
Tissues


![]()
ABSTRACT
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
![]()
INTRODUCTION
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
![]()
MATERIALS AND METHODS
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
75°C. Tonsil biopsy specimens were obtained at 0, 4, 24, and 48 weeks, immediately snap-frozen by immersion in liquid nitrogen, and
stored in liquid nitrogen. Tissues were further processed by
cryosectioning of unfixed frozen biopsy specimens (6-µm sections). Individual or multiple frozen sections were placed in 1.5-ml screw-top tubes (Sarstedt, Nurnbrecht, Germany) at
20°C, and the tubes were
stored at
75°C until the samples were used for RNA extraction. Cultured HIV-uninfected H9 cells (ATCC HTB 176) or HIV-infected 8E5
cells (ATCC CRL 8993) were stored at
20°C as "dry" pellets containing 106 cells. Plasma specimens from 28 patients,
PBMC specimens from 9 patients, and tonsil specimens from 7 patients
were assessed to collect the data presented in this report.
70°C until it was needed for RT-PCR.
Up to 12 specimens could be processed simultaneously with a 12-place
manifold and multiple channels on the peristaltic pump.
Extraction of RNA from PBMCs and tissues.
Extraction of RNA
from cultured cells, PBMCs, and tonsil specimens was performed with the
RNeasy Kit (Qiagen) according to the manufacturer's instructions, with
minor modifications. Briefly, 106 to 107 frozen
PBMCs or 0.05 to 1.0 mg of tissue (1 to 20 frozen 6-µm sections) was
dissolved in 0.6 ml of Qiagen RNeasy lysis buffer. The cell-lysis
buffer mixtures were further dissociated by passage through a
Qiashredder column (Qiagen). Total RNA was then extracted with an
RNeasy spin column (Qiagen). After elution with 100 µl of diethyl
pyrocarbonate-treated water and adjustment of the eluate to 10 mM
MgCl2 and 10 mM Tris HCl (pH 7.5), residual DNA was
digested with 10 U of RNase-free DNase I (Boehringer, Mannheim,
Germany) for 15 min at 37°C. The DNase-treated RNA was repurified
with another RNeasy column and was eluted in 100 µl of diethyl
pyrocarbonate-treated water. The purified RNA was stored at
75°C
until it was needed.
RT-PCR. RNA extracted with silica columns was analyzed by the Amplicor HIV-1 Monitor test. QIAamp-extracted plasma RNA (50 µl that already contained QS) was mixed with 50 µl of the Amplicor Master Mix. RNeasy-extracted total cellular RNA (3 to 30 µl) was mixed with 50 µl of Amplicor Master Mix, 0.83 µl of QS (70 to 90 copies of QS, depending on the batch used), and sample diluent (from the Amplicor test kit) to a final volume of 100 µl. Regardless of the extraction method, the amount of QS added to each specimen was calculated so that the numbers of copies of QS in each amplification reaction were the same as the number recommended for the unmodified Amplicor test. Thermal cycling and detection were performed according to the Amplicor test instructions. Limits of detection were determined by comparison of the QS internal controls with a constant cutoff value (0.2 optical density [OD] unit) for positive HIV results, as suggested in the manual for the Amplicor test, by the following formula: absolute detection limit (number of copies per PCR mixture) = 0.2 OD × input number of QS copies/PCR)/(total QS OD). Relative detection limits were calculated from the latter by normalizing to the sample input. Thus, relative detection limits are expressed as number of copies per milliliter for plasma and as number of copies per microgram of total RNA or as number of copies per cell equivalent for cellular specimens.
Statistics and calculations. Statistical analyses were carried out with GraphPad Prism software, version 2.01 (AMPL Software Pty. Ltd., Turramurra, Australia). Unless stated otherwise, calculated values are followed by the standard error (SE).
Calculations of plasma HIV-1 RNA copy numbers were done according to the Amplicor instructions, except that the dilution factor was adjusted to reflect the volume of plasma represented in each reaction mixture. For cellular RNA, the number of HIV RNA copies per reaction mixture was divided by the micrograms of total RNA added to that reaction mixture, resulting in the number of HIV-1 RNA copies per microgram of total RNA (number of copies of HIV RNA per microgram of RNA).| |
RESULTS |
|---|
|
|
|---|
Quantitation of HIV-1 RNA from plasma.
Recovery of native
HIV-1 RNA from plasma was tested by spiking HIV-negative plasma with
clinically obtained HIV-1-positive plasma resulting in 22 mixtures
containing 30 to 27,000 HIV-1 RNA copies/ml (Fig.
1). Linear regression of
log10(QIAamp viral load) versus log10(expected
viral load) demonstrated a strong correlation over the range tested
(r2=0.91), with a slope of 0.97 ± 0.07, which was not significantly different from 1 (P = 0.67;
t test) and a y intercept of
0.14 ± 0.18. Among
the nine specimens within this data set with expected viral loads of
<200 copies/ml (range, 32 to 110 copies/ml), only one was negative
(expected viral load, 73 copies/ml; measured load, <17 copies/ml).
|
|
Quantitation of HIV-1 RNA from cells. The RNeasy RNA extraction kit (Qiagen) was used to extract total RNA from cultured cells, PBMCs, and tonsil biopsy specimens. With 106 H9 cells per extraction, the RNeasy kit produced an average RNA yield of 12.1 ± 0.4 µg/106 H9 cells (11 specimens were tested). In experiments with 106 to 107 cells per extraction with PBMCs from two HIV-negative donors, the average yield was 1.1 ± 0.1 µg of total RNA/106 PBMCs (six specimens were tested). The average yield of RNA from tonsil tissue was 2.8 ± 0.4 µg/mg of tissue (27 specimens tested).
To assess the linearity of HIV-1 RNA quantitation, fresh HIV-infected 8E5 cells were mixed with uninfected H9 cells to create controls containing 2, 10, 100, or 1,000 8E5 cells per 106 H9 cells. Aliquots of silica-extracted RNA from each mixture were amplified with the Amplicor test kit (Fig. 2). The correlation between input the number of 8E5 cell equivalents and the number of HIV-1 RNA copies was linear over the range tested (0.06 to 34 infected cell equivalents per PCR; 20 to 19,000 HIV-1 RNA copies per PCR; r2 = 0.91), and the slope (0.90) was not significantly different from 1 (P = 0.40; t test).
|
Elimination of DNA from cellular RNA. Considering that very small amounts of cellular HIV-1 RNA are to be measured to monitor HIV-infected patients receiving HAART, we addressed the question of whether low-positive measurements obtained from cellular RNA reflect viral RNA or proviral DNA contaminating the RNA preparation. To avoid false-positive results due to the presence of HIV DNA, a DNase digestion step was included in the protocol for the preparation of cellular RNA. The absence of contaminating genomic DNA was routinely monitored by gel electrophoresis of PBMC and tissue RNA preparations (data not shown).
The efficacy of the DNase digestion was documented by spiking HIV-negative RNA preparations with known numbers of copies of cloned HIV-1 DNA and then digesting the specimen with DNase by the routine procedure and measuring the residual DNA by the Amplicor test. DNase digestion completely removed 200 copies of amplifiable HIV-1 DNA (Table 2). With 20,000 HIV-1 DNA input copies, the spiked HIV-1 DNA level was reduced by more than 7,000-fold (Table 2). Furthermore, in patient specimens which had been treated with DNase twice, the second treatment had no measurable effect on the result of the RT-PCR (Table 2). The finding that the plasmid DNA copy numbers measured by the Amplicor test were, in some instances, higher than the expected value (Table 2) may reflect the higher degree of chemical stability of DNA compared to that of the QS RNA.
|
Quantitation of HIV-1 RNA in clinical specimens. To assess the applicability of these methods to the monitoring of antiretroviral drug therapy, plasma virus loads, the number of HIV-1 RNA copies in PBMCs, and the number of HIV-1 RNA copies in tonsil biopsy specimens were measured over time in specimens from a representative HIV-infected patient taking AZT, 3TC, and ritonavir (Fig. 3). When measuring the plasma virus load by the standard Amplicor test, the last time point with detectable viremia was week 4. All specimens collected beyond that time point were assessed by both the standard Amplicor test and the silica-based (QIAamp) Amplicor test. The silica-based Amplicor procedure detected plasma HIV-1 RNA on weeks 8 and 40 (24 and 28 copies/ml, respectively). In agreement with the analysis whose results are presented in Table 1, relative detection limits (presented here only when no viral RNA could be measured) were about 1 log lower for the QIAamp procedure than for the standard Amplicor test. The levels of the cellular HIV-1 RNA in both the PBMC and the tonsil compartments showed clear decreases after the onset of therapy. In the initial phase before and shortly after the initiation of therapy, when virus was detectable in plasma, the kinetics of the PBMC and plasma HIV-1 RNA levels were similar, albeit at an overall lower (1 to 2 logs) level, and the dynamic range for PBMCs was smaller. At later time points, when the amount of virus in plasma was usually below the limit of detection, HIV-1 RNA persisted in PBMCs at 3 to 10 copies/µg of RNA.
|
| |
DISCUSSION |
|---|
|
|
|---|
Use of the methods presented here resulted in a highly sensitive means of detection of HIV-1 RNA in plasma, with an average lower detection limit of 14.9 copies per ml, and in cellular specimens, with an average lower detection limit of 2.4 copies per µg of total cellular RNA. This was achieved by silica column extraction of total RNA from plasma, PBMC, or tissue specimens followed by the addition of the purified RNA to the Amplicor HIV-1 Monitor test.
Some previously reported boosted methods for measurement of the plasma virus load rely on virus concentration by high-speed centrifugation followed by Amplicor RT-PCR (7, 10). However, this approach does not control for the possibility of incomplete recovery of virus by the centrifugation step because the QS RNA is added after centrifugation, when the lysis buffer added at this stage protects the QS RNA from nucleases. In the silica-based Amplicor method, RNA is extracted directly from plasma with the QIAamp Viral RNA Kit (Qiagen). In this protocol the QS RNA is added before extraction, which, like the standard Amplicor test, controls for the efficiency of extraction as well as that of amplification.
The linearity of the silica-based method was similar to that for the unmodified Amplicor test, which is claimed by the manufacturer to extend from approximately 8 to 18,000 HIV-1 RNA copies per amplification. When using 0.025 ml of plasma per PCR mixture (standard Amplicor test), this represents approximately 320 to 720,000 HIV-1 RNA copies per ml of plasma. When using 0.5 ml of plasma, a range from approximately 16 to 32,000 HIV-1 RNA copies per ml can be expected. In good accordance with those expected ranges, our data for specimens from which RNA was extracted with silica show linearity in a range from 30 to 27,000 HIV-1 copies/ml and an average lower relative detection limit of 16 copies/ml. If needed, plasma virus load measurements might be boosted further. For instance, Shafer and colleagues (11) boosted their nested HIV RT-PCR by combining centrifugation-based concentration with silica extraction. Also, the silica extraction method presented here may be developed further to accommodate larger plasma volumes. In preliminary experiments, we successfully performed silica extraction with up to 3 ml of plasma (unpublished observations).
Total cellular RNA purified with RNeasy silica columns was added to the Amplicor test to quantitate HIV-1 RNA from PBMCs and tonsil biopsy specimens. In contrast to the extraction of plasma, the extraction procedure itself is not controlled by coextraction of the QS RNA. Appropriate normalization of the input is, however, achieved by the measurement of the concentration of total RNA. In our hands, up to 2.6 µg of extracted total RNA could be added to an amplification reaction without significant inhibition, resulting in an average lower detection limit of 2.4 HIV-1 RNA copies per µg of total RNA. Addition of purified cellular RNA to the Amplicor test was previously reported by Tamalet et al. (12), who monitored HAART by measuring HIV transcription in PBMCs and lymphoid cells. Their method differs from our protocol in the following two main ways: (i) QS RNA was added to lysed cells before extraction (as is done with the standard Amplicor extraction and the boosted method with QIAamp silica for plasma RNA), and (ii) about 5- to 10-fold less RNA (250,000 cell equivalents, or approximately 0.28 µg of total RNA [our calculations based on their data]) extracted by a guanidine-phenol-based method was added to the Amplicor test mixture.
Those investigators reported detectable HIV-1 RNA levels of less than 50 copies per 106 cells in patients receiving HAART for 8 weeks. Thus, their method appears to give results similar to those achieved by the protocol for cellular specimens reported here. However, our method offers the advantage of increasing the amount of input RNA, resulting in improved sensitivity.
The expected sensitivity and precision obtained by combining silica-based extraction with the Amplicor test were realized in clinical plasma, PBMC, and tonsil biopsy tissue specimens obtained from our ongoing study of antiretroviral therapy (EARTH study). Data for a representative patient are reported here. Detectable levels of HIV-1 RNA from PBMCs in the face of undetectable HIV-1 RNA in plasma (<20 copies/ml) attest to the sensitivity of the Amplicor RT-PCR with silica-extracted cellular specimens. The usefulness of these methods was substantiated by the following observations. In a subset of 16 patients receiving double- or triple-drug therapy, the numbers of copies of HIV-1 RNA in plasma, PBMCs, and, where available (13 patients), tonsil tissue were assessed by the methods described here during 1 year (unpublished data). That analysis revealed that the levels of HIV-1 transcripts were significantly correlated (P > 0.001) between PBMCs and plasma, PBMCs and tonsil tissue, and plasma and tonsil tissue (Spearman r values = 0.71, 0.61, and 0.62, respectively).
The relative ease of performance of these procedures with clinical specimens makes the tests well-suited for large-scale screening in the context of clinical studies, and our laboratory uses these methods routinely. Another potential advantage of measuring RNA in specimens of both cellular and cell-free origin by the same well-characterized RT-PCR method is that the levels of viral RNA in different compartments can be directly compared.
In summary, the methods described here provide highly sensitive, reproducible, and simplified tests for the measurement of HIV-1 RNA in plasma, PBMC, and frozen tissue biopsy specimens. Application to clinical research specimens may enhance the throughput and quality of the data, especially for patients in whom residual viral RNA levels are very low due to HAART.
| |
ACKNOWLEDGMENTS |
|---|
This work was supported by the Kanton of Zurich and by Swiss National Science Foundation grants 32-46016 and 3239-043654.
We thank the following members of the Infectious Diseases Division, University Hospital Zurich: Friederike Burgener for laboratory assistance, Christina Grube for clinical assistance, and Beda Joos for helpful discussions. We also thank Ruth Martin (Roche, Switzerland) and Kurt Zoller (Qiagen, Switzerland) for helpful cooperation.
| |
FOOTNOTES |
|---|
* Corresponding author. Mailing address: University Hospital, Division of Infectious Diseases, Raemistrasse 100, CH-8091 Zurich, Switzerland. Phone: 41-1-255-3610. Fax: 41-1-255-3291. E-mail: inffia{at}usz.unizh.ch.
Present address: Swiss Serum and Vaccine Institute Bern, CH-3001
Bern, Switzerland.
Present address: Carmenstrasse 23, CH-8032 Zurich, Switzerland.
| |
REFERENCES |
|---|
|
|
|---|
| 1. | Ausubel, S. M., R. M. Brent, R. E. Kingston, D. D. Moore, J. G. Seldmann, J. G. Smith, and K. Struhl. 1987. Current protocols in molecular biology. John Wiley & Sons, Inc., New York, N.Y. |
| 2. |
Cavert, W.,
D. W. Notermans,
K. Staskus,
S. W. Wietgrefe,
M. Zupancic,
K. Gebhard,
K. Henr,
Z. Q. Zhang,
R. Mills,
H. McDade,
J. Goudsmit,
S. A. Danner, and A. T. Haase.
1997.
Kinetics of response in lymphoid tissues to antiretroviral therapy of HIV-1 infection.
Science
276:960-964 |
| 3. |
Finzi, D.,
M. Hermankova,
T. Pierson,
L. M. Carruth,
C. Buck,
R. E. Chaisson,
T. C. Quinn,
K. Chadwick,
J. Margolick,
R. Brookmeyer,
J. Gallant,
M. Markowitz,
D. D. Ho,
D. D. Richman, and R. F. Siliciano.
1997.
Identification of a reservoir for HIV-1 in patients on highly active antiretroviral therapy.
Science
278:1295-1300 |
| 4. |
Gulick, R. M.,
J. W. Mellors,
D. Havlir,
J. J. Eron,
C. Gonzalez,
D. McMahon,
D. D. Richman,
F. T. Valentine,
L. Jonas,
A. Meibohm,
E. A. Emini, and J. A. Chodakewitz.
1997.
Treatment with indinavir, zidovudine, and lamivudine in adults with human immunodeficiency virus infection and prior antiretroviral therapy.
N. Engl. J. Med.
337:734-739 |
| 5. | Hahn, B. H., G. M. Shaw, S. K. Arya, M. Popovic, R. C. Gallo, and F. Wong Staal. 1984. Molecular cloning and characterization of the HTLV-III virus associated with AIDS. Nature 312:166-169[Medline]. |
| 6. | Michael, N. L., T. Mo, A. Merzouki, M. O'Shaughnessy, C. Oster, D. S. Burke, R. R. Redfield, D. L. Birx, and S. A. Cassol. 1995. Human immunodeficiency virus type 1 cellular RNA load and splicing patterns predict disease progression in a longitudinally studied cohort. J. Virol. 69:1868-1877[Abstract]. |
| 7. | Mulder, J., R. Resnick, B. Saget, S. Scheibel, S. Herman, H. Payne, R. Harrigan, and S. Kwok. 1997. A rapid and simple method for extracting human immunodeficiency virus type 1 RNA from plasma with enhanced sensitivity. J. Clin. Microbiol. 35:1278-1280[Abstract]. |
| 8. | Revets, H., D. Marissens, S. de Wit, P. Lacor, N. Clumeck, S. Lauwers, and G. Zissis. 1996. Comparative evaluation of NASBA HIV-1 RNA QT, AMPLICOR-HIV monitor, and QUANTIPLEX HIV RNA assay, three methods for quantification of human immunodeficiency virus type 1 RNA in plasma. J. Clin. Microbiol. 34:1058-1064[Abstract]. |
| 9. | Saksela, K., C. E. Stevens, P. Rubinstein, P. E. Taylor, and D. Baltimore. 1995. HIV-1 messenger RNA in peripheral blood mononuclear cells as an early marker of risk for progression to AIDS Ann. Intern. Med. 123:641-648. |
| 10. | Schockmel, G. A., S. Yerly, and L. Perrin. 1997. Detection of low HIV-1 RNA levels in plasma. J. Acquired Immune Defic. Syndr. Hum. Retrovirol. 14:179-183[Medline]. |
| 11. | Shafer, R. W., D. J. Levee, M. A. Winters, K. L. Richmond, D. Huang, and T. C. Merigan. 1997. Comparison of QIAamp HCV kit spin columns, silica beads, and phenol-chloroform for recovering human immunodeficiency virus type 1 RNA from plasma. J. Clin. Microbiol. 35:520-525[Abstract]. |
| 12. | Tamalet, C., A. Lafeuillade, J. Fantini, C. Poggi, and N. Yahi. 1997. Quantification of HIV-1 viral load in lymphoid and blood cells; assessment during four-drug combination therapy. AIDS 11:895-901[Medline]. |
| 13. |
Wong, J. K.,
H. F. Gunthard,
D. V. Havlir,
T. Q. Zhang,
A. T. Haase,
C. C. Ignacio,
S. Kwok,
E. Emini, and D. D. Richman.
1997.
Reduction of HIV-1 in blood and lymph nodes following potent antiretroviral therapy and the virologic correlates of treatment failure.
Proc. Natl. Acad. Sci. USA
94:12574-12579 |
| 14. |
Wong, J. K.,
M. Hezareh,
H. F. Gunthard,
D. V. Havlir DV,
C. C. Ignacio,
C. A. Spina, and D. D. Richman.
1997.
Recovery of replication-competent HIV despite prolonged suppression of plasma viremia.
Science
278:1291-1295 |
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Antimicrob. Agents Chemother. | Clin. Microbiol. Rev. |
|---|---|
| Clin. Vaccine Immunol. | ALL ASM JOURNALS |
|---|