Previous Article | Next Article ![]()
Journal of Clinical Microbiology, February 2000, p. 688-695, Vol. 38, No. 2
McArdle Laboratory for Cancer
Research1 and Department of Human
Oncology,7 University of Wisconsin Medical
School, and Epicentre Technologies,2
Madison, Wisconsin; Department of Virology,
Umeåa,3 and Karolinska Institute,
Stockholm,4 Sweden; and University of
South Carolina School of Medicine5 and
University of South Carolina School of Public
Health,6 Columbus, South Carolina
Received 4 May 1999/Returned for modification 11 August
1999/Accepted 22 November 1999
Many human papillomavirus (HPV) genotypes are associated with
cervical carcinoma. We demonstrate the utility of an innovative technique for genotyping of HPV in cervical tissue samples. This method
provides an accurate means of identification of the specific HPV
genotypes present in clinical specimens. By using the MY09-MY11 and the
GP5+-GP6+ consensus primer pairs, HPV sequences
were amplified by nested PCR from DNA isolated from cervical smear
samples. This led to the production of an approximately 140-bp PCR
product from the L1 (major capsid) gene of any of the HPVs present in
the sample. PCR was performed with a deoxynucleoside triphosphate
mixture which resulted in the incorporation of deoxyuridine into the
amplified DNA product at positions where deoxythymidine would normally
be incorporated at a frequency of about once or twice per strand. Following the PCR, the product was treated with an enzyme mix that
contains uracil N-glycosylase (UNG) and endonuclease IV. UNG removes the uracil base from the nucleotide, and endonuclease IV
cleaves the phosphodiester bond at this newly formed abasic site,
producing fragments of various sizes. By having end labeled one of the
amplification primers, a DNA ladder which is analogous to a
"T-sequencing ladder" was produced upon electrophoresis of the
products. By comparing this T-sequencing ladder to the known sequences
of HPVs, the genotypes of unknown HPV isolates in samples were
assigned. Data showing the utility of this technique for the rapid
analysis of clinical samples are presented.
Human papillomaviruses (HPVs) are
small double-stranded DNA viruses that infect the human epithelium and
cause hyperproliferation (16). There are over 70 genotypes
of HPVs; one subset causes common warts and the other subset, which
infects anogenital mucosa, causes genital warts (11). Within
the anogenital HPVs a subgroup termed the "high-risk" HPVs is
associated with greater than 90% of cervical cancers, a leading cause
of death by cancer in women worldwide (19). Early detection
of preneoplastic and neoplastic lesions in the cervix through the use
of Pap smears has led to a reduction in the number of deaths due to
cervical cancer in countries where women have good access to health
care. With the appreciation of the role of HPVs in cervical cancer,
there is a growing appreciation of the potential value for routine
screening of female patients not only for cytological abnormalities
present in cervical lavage specimens (Pap smears) but also for the
presence and type of HPV (2).
Currently, two main approaches are used to screen clinical specimens
for the presence of HPV: (i) PCR with consensus primers that amplify a
region of the major viral capsid L1 gene that is highly conserved among
anogenital HPVs (14) and (ii) the Hybrid II Capture Assay
(Digene Diagnostics, Inc.), which detects the presence of either
high-risk or low-risk HPVs by formation of DNA-RNA hybrids
(17). While consensus primer-based PCR allows the detection
of HPV DNA, it gives little information about the genotype of HPV
present. The Hybrid II Capture Assay can show the presence of most of
the high-risk HPVs by using the high-risk HPV RNA probe mix or low-risk
HPVs by using the low-risk HPV RNA probe mix, but it does not give any
genotype-specific information.
In order to obtain HPV genotype information from clinical specimens,
genotyping techniques have been developed. One approach is to use a
pool of genotype-specific primers in a PCR (4). This leads
to the amplification of a portion of certain HPVs if they are present
in the sample. Because the various HPV genotypes will give amplimer
products of different sizes, a genotype can be assigned by measuring
the size of a product on an ethidium bromide-stained gel or using
Southern hybridization and comparing the amplimer size to what would be
expected from the various HPV genotypes. The drawbacks to this method
are that it can be labor-intensive, especially if Southern
hybridization is performed, and it tests for only a small number of HPV
genotypes. A reverse line blot detection method in which PCR is
performed with consensus primers has also been developed (7,
8). The product is then used to probe a nylon strip containing
immobilized DNAs of several HPV genotypes. While this technique gives
an exact genotype, only 27 HPV genotypes are screened by this assay.
The "gold standard" for HPV genotyping is sequencing, in which HPV
DNA is amplified with consensus primers and the product is cloned into
a plasmid and is sequenced. While this technique gives the most
conclusive genotype information, it is the most labor-intensive.
We describe here a simple, rapid, one-step PCR-based technique for
genotyping of HPVs in clinical samples. The method should be easily
adaptable to high-throughput screening with automated sequencing
hardware. This technique uses the BESS-T Base Reader Kit (Epicentre
Technologies, Madison, Wis.) protocol to genotype the HPV DNA present
in clinical samples. The protocol involves performance of PCR with
samples by using the same HPV L1 consensus primers that are already
being used for high-sensitivity HPV detection. The PCR conditions are
modified; one of the primers is end labeled with either a radioactive
or a fluorescent probe and the BESS deoxynucleoside triphosphate (dNTP)
mix, which contains dUTP, is used. The PCR product is digested for a
half hour by using an enzyme mixture that cleaves a DNA strand wherever
dUTP has been incorporated (9). The cleaved products are run
on a sequencing or capillary gel producing a "T-sequencing ladder"
that is unique to a specific HPV genotype. The T-sequencing ladder is
compared to theoretical T-sequencing ladders in order to assign a
specific genotype to the sample.
DNA preparation from paraffin-embedded tissue.
Paraffin-embedded tissue sections (10 µm) were prepared for testing
as described below by a modified version of a previously described
technique (14). Paraffin was removed from tissue sections that were transferred to microcentrifuge tubes by two extractions with
1 ml of xylenes. Excess xylenes were removed by two extractions with 1 ml of 100% ethanol. Dried tissue samples were resuspended in 100 µl
of "K buffer" (50 mM KCl, 10 mM Tris-HCl [pH 8.3], 2.5 mM
MgCl2, 100 µg of gelatin per ml, 0.45% IGEPAL, 0.45%
Tween 20, 60 µg proteinase K per ml) and were incubated at 55°C for 3 h and then at 95°C for 10 min. The debris was pelleted, and 3 µl of the supernatant was used for PCR.
DNA preparation from cervical scrapes.
Samples were
collected and DNA was prepared as described previously (5,
6). Briefly, a cotton-tipped swab was scraped over the surface of
the portio vaginalis. The cells on the swab were collected by placing
the swab in a plastic tube containing 1.5 ml of STE (0.1 M NaCl, 10 mM
Tris-HCl [pH 8.0], and 1 mM EDTA). The cells were centrifuged, washed
twice with phosphate-buffered saline, and incubated at 60°C for
1 h in 100 µl of lysis buffer (10 mM Tris-HCl [pH 7.9], 0.45%
Nonidet P-40, 0.45% Tween 20, 60 µg of proteinase K per ml),
followed by incubation at 95°C for 10 min. A total of 10 to 25 µl
of the solution was used for PCR.
PCR amplification.
HPV DNA was amplified by two approaches.
Both approaches used the MY09-MY11 consensus primer pair (which
amplifies nucleotides 6722 to 7170 in HPV type 6 [HPV-6] and the
corresponding regions of the other genital HPVs) and the primer pair
GP5+-GP6+ (which amplifies nucleotides 6764 to
6902 in HPV-6 and the corresponding regions of other HPVs) in a nested
PCR (3, 14). DNA prepared from paraffin-embedded tissue was
placed in a PCR mixture with 1× PCR buffer (Boehringer Mannheim), 200 µM dNTP, 1 µM MY09, 1 µM MY11, 3.5 mM MgCl2, and 0.5 U of Taq polymerase (Boehringer Mannheim). Twenty cycles
were performed, with denaturation at 94°C for 1 min, annealing at
50°C for 1 min, and polymerization at 72°C for 1 min. A total of
0.5 µl of this PCR product was then used in a subsequent PCR. The
conditions were the same as those for the previous PCR, with the
exceptions that the dNTP mixture was replaced by the dNTP mixture
supplied in the BESS-T Base Reader Kit, which contains a small amount
of dUTP, and the MY09-MY11 primer pair was replaced by 5 pmol of
GP6+ and 4 pmol of Sequencing of PCR samples.
Samples were PCR amplified as
described above by using cold GP5+-GP6+.
Sequencing was then performed with this product by cycle sequencing. Two microliters of the PCR amplimer was mixed with 4 µl of ABI PRISM
BigDye Terminator Ready Reaction Mix (Perkin-Elmer), 4 µl of dilution
buffer (400 mM Tris-HCl [pH 8.3], 10 mM MgCl2), 3.2 µl
of 1 µM primer (GP5+ or GP6+), and 6.8 µl
of double-distilled H2O. The 20-µl reaction mixture was
treated for 5 s at 96°C, followed by 25 cycles of 96°C for 10 s, 50°C for 5 s, and 60°C for 4 min. The products were
then passed through CENTRI-SEP Spin Columns (Princeton Separations) and
dried in a Speed-Vac. The samples were resuspended in 4.5 µl of
resuspension solution (1 part loading dye [25 mM EDTA {pH 8.0}, 50 mg of blue dextran per ml] and 8 parts of deionized formamide). Two
microliters of this was then run on an ABI 377 instrument and analyzed
with Lasergene99 (DNASTAR Inc.) software.
PCR with fluorescently labeled primers.
The PCR mixture
contained 1 ng of HPV plasmid DNA or 3 to 5 µl of cells in lysis
buffer from cervical scrapes, 1× PCR buffer, 1 U of MasterAmp
Taq DNA polymerase (Epicentre Technologies), 2.5 mM
MgCl2, 200 µM BESS-T Base Reader dNTP mix, 10 pmol of
MY09, and 10 pmol of MY11, which was 5' end labeled with 6-FAM.
6-FAM-labeled oligonucleotides (obtained from Operon Technologies,
Inc., Alameda, Calif.) were synthesized by the beta-cyanoethyl
phosphoramidite method with 6-FAM phosphoramidite. Cycling conditions
were 94°C for 2 min, followed by 29 cycles of 94°C for 1 min,
58°C for 1 min, and 73°C for 1 min and a final extension of 73°C
for 4 min.
BESS-T Base Reader Kit reactions.
Ten microliters of the
final PCR product was incubated with 1.2 µl of 10× excision buffer
and 1.0 µl of BESS-T Excision Enzyme Mix for 30 min at 37°C. The
reaction was stopped by adding 6 µl of stop-loading dye.
32P-labeled samples were incubated at 75°C for 5 to 10 min, and 2 µl was loaded and run on an 8% denaturing polyacrylamide
gel. The banding patterns were visualized with a PhosphorImager
(Molecular Dynamics) and by radiography. Fluorescently labeled samples
were run on an ABI 310 automated sequencer and analyzed with GeneScan software (10).
Genotyping with genotype-specific primers.
Cervical scrape
samples which were positive for HPV DNA were genotyped with
genotype-specific primers as described previously (4).
The goal of this study was to test the feasibility of using the
BESS-T Base Reader Kit methodology for genotyping of the HPV DNA
present in clinical samples. The BESS-T Base Reader Kit methodology (Fig. 1) makes use of bacterial enzymes
(uracil N-glycosylase and endonuclease IV) to cleave a
polydeoxyribonucleic acid chain at the positions of uracils
(9). HPV DNA was amplified by PCR. dUTP was added to the PCR
mixture, leading to its infrequent incorporation into the newly
synthesized DNA products at positions where dTTP is normally
incorporated. Treatment of the amplified product (the amplimer) with
the enzymes mentioned above led to removal of the uracil base wherever
it was incorporated and consequent chain breakage. Thus, for each
strand, a set of cleavage products reflective of the positions where T
residues normally reside were obtained. Because one of the primers used
in the PCR was end labeled, one could selectively visualize the
products from this strand by autoradiography or a nonradioactive
detection method. The pattern of the products generated upon their
electrophoresis on a denaturing polyacrylamide gel or capillary gel
were equivalent to the T-sequencing ladder one would generate for the
same DNA segment by performing a Sanger sequencing reaction with ddTTP.
0095-1137/00/$04.00+0
Copyright © 2000, American Society for Microbiology. All rights reserved.
A Novel and Rapid PCR-Based Method for Genotyping
Human Papillomaviruses in Clinical Samples

![]()
ABSTRACT
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
![]()
INTRODUCTION
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
![]()
MATERIALS AND METHODS
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References
-32P-end-labeled
GP5+. The PCR was performed as described above for 25 cycles. The cervical scrape samples were amplified by the nested PCR
that was described previously (1). A total of 0.5 µl of
this PCR product was used in a PCR mixture which was the same as that
for the second PCR step described above for the paraffin-embedded tissue samples with GP6+,
-32P-end-labeled
GP5+, and the dNTP mixture containing dUTP. In all PCR
experiments, negative and positive controls were included. For negative
controls PCR was carried out in the absence of template and in the
presence of DNA isolated from the HPV-negative cervical cancer cell
line C33A. For positive controls PCR was carried out with recombinant plasmids containing the HPV-16, HPV-18, or HPV-31b genomes and DNAs
isolated from the HPV-positive cervical cancer cell lines Caski and SiHa.
-32P end labeling of GP5+.
GP5+ was
-32P end labeled in a 25-µl
kinase reaction with 1 µl of 50 µM GP5+, 2.5 µl of
10× polynucleotide kinase (Boehringer Mannheim), 2.5 µl of 1 U of
polynucleotide kinase (Boehringer Mannheim) per µl, 2.5 µl of
[
-32P]ATP (3,000 Ci/mmol), and 16.5 µl of
double-distilled H2O. The reaction mixture was incubated at
37°C for 30 min, followed by an incubation at 75°C for 10 min. The
resulting solution was passed through a Quick Spin Column (Sephadex
G-25; Fine; Boehringer Mannheim).
![]()
RESULTS
Top
Abstract
Introduction
Materials and Methods
Results
Discussion
References

View larger version (22K):
[in a new window]
FIG. 1.
Principle behind use of BESS-T Base Reader Kit method
for genotyping of HPVs. A schematic outlining the key steps in the
BESS-T Base Reader Kit method is shown. In step 1, a DNA template is
amplified by the PCR method. Standard PCR conditions were modified in
two essential ways: (i) one of the primers is 32P end
labeled and (ii) dNTP is spiked with dUTP. The resulting PCR products
have dUTP randomly incorporated into each strand in place of dTTP at an
average frequency of one to two dUTP residues per DNA molecule. In step
2, the PCR products are treated with the uracil
N-glycosylase and endonuclease IV, causing the cleavage of
DNA strands at deoxyuridine (
) residues. In step 3, the cleaved,
32P-end-labeled PCR products (shaded typeface) are made
single stranded and are electrophoretically resolved on a denaturing
polyacrylamide gel, and the labeled products are visualized by
autoradiography or with a PhosphorImager (Molecular Dynamics). Shown at
the bottom is an idealized autoradiographic result. In lane 2 are
resolved the two 32P-end-labeled cleavage products
displayed in step 2. Lane 1 represents a DNA ladder in which each DNA
fragment differs by one nucleotide in length. The banding pattern
generated with the BESS-T Base Reader Kit is equivalent to that
generated by performing a Sanger sequencing reaction with ddTTP.
To genotype HPVs in clinical samples we combined use of this BESS-T Base Reader Kit methodology and PCR amplification of segments of the HPV genomes using consensus primers. PCR is the most sensitive technique available for the detection of HPV DNA in clinical samples (14). The standard approach is to perform PCR with pairs of consensus oligonucleotides designed to direct amplification of a segment of the viral genomes of most HPV genotypes. MY09-MY11 is such a consensus primer pair; these primers direct amplification of a portion of the viral L1 capsid gene (14). The GP5+-GP6+ primer pair, which amplifies a region contained within the MY09-MY11 amplimer, is commonly used together with the MY09-MY11 primer pair in nested PCRs to yield information regarding the HPV status of clinical samples (5). We compared the predicted T-ladder banding pattern for all known anogenital HPVs for the region amplified by the GP5+-GP6+ primer pair (Fig. 2). The T-ladder banding pattern was unique for each HPV genotype compared. As one might predict, similarities in banding patterns reflected the previously ascribed phylogenetic relationships among these HPVs (15). This analysis indicated the potential utility of the BESS-T Base Reader Kit for genotyping of the anogenital HPVs.
|
Using recombinant HPV type 16, 18, and 31 plasmid DNAs as templates and the GP5+-GP6+ primer pair (GP5+ was 32P end labeled), we compared the patterns of the labeled products obtained by the BESS-T Base Reader Kit method (Fig. 3A) to the predicted T-ladder pattern (Fig. 2). A perfect correlation was observed. The individual bands obtained with the BESS-T Base Reader Kit were equivalent in their intensities throughout the region amplified, indicating that the method permits facile identification of all T positions in a sequence. This experiment provided proof of principle.
|
We next tested the utility of this BESS-T Base Reader Kit method for
genotyping of the HPV DNAs present in clinical samples. For this
purpose we analyzed 30 coded samples obtained from an ongoing
prospective study of European women in which the incidence of
HPV-related diseases is being monitored (12, 13). The
samples obtained were DNA samples from cervical scrapes that had been subjected to nested PCR with the MY09-MY11 plus
GP5+-GP6+ primer pairs. Twenty-eight of the 30 samples had been demonstrated by this PCR methodology to be positive
for HPV DNA. Two of the 30 samples were known to be negative for a
detectable HPV-specific PCR product. The 28 HPV-positive samples had
been analyzed initially for HPV genotype by using genotype-specific
primer pairs specific for a limited number of common anogenital HPVs
(HPV types 6, 11, 16, 18, and 33). Fifteen of these 28 HPV-positive
samples were determined to be positive for at least one of these common
HPVs; the other 13 HPV-positive samples did not yield PCR amplimers with this limited set of genotype-specific primer pairs (Table 1). We subjected all 30 coded samples to
testing with the BESS-T Base Reader Kit using the
GP5+-GP6+ primer pair in which the
GP5+ primer was 32P end labeled. As predicted,
28 of the 30 samples yielded 32P-labeled PCR products.
Cleavage of the amplimers with uracil N-glycosylase and
endonuclease IV led to the generation of multiple products for each of
the 28 positive samples, yielding specific banding patterns upon their
electrophoresis on a denaturing polyacrylamide gel (Fig. 3B). These
banding patterns were compared to the predicted T-ladder banding
patterns for individual anogenital HPVs (Fig. 2). From this comparison,
specific genotypes could be ascribed to 26 of the 28 HPV-positive
samples (Table 1). The two HPV-positive samples that could not be
genotyped (samples 23 and 28) appeared to have a mixture of at least
two different HPV genotypes, as deduced by (i) the presence of two
full-length products evident toward the top of the lanes in Fig. 3B for
each of these samples, (ii) the complexities of the banding patterns in
these two lanes, and (iii) the complexity of the banding pattern seen
by sequence analysis of the GP5+-GP6+ amplimer
(data not shown). Mixtures of uncleaved products were also evident in
samples 1 and 7; however, for these samples one product predominated
over the other, allowing the successful genotyping of the isolates in
those samples. The results that were obtained from the BESS-T Base
Reader Kit analysis and that are illustrated in Fig. 3B were confirmed
by duplicate analysis of these samples (data not shown), demonstrating
the reproducibility of this technique.
|
Once the genotypes were assigned for the 30 samples, the code was broken and the genotype information obtained from the BESS-T Base Reader Kit was compared to the HPV status and HPV genotype information obtained from prior analyses of these samples (Table 1). The same 28 samples that were HPV positive in the initial nested PCR analysis were HPV positive by analyses with the BESS-T Base Reader Kit. Among the 15 HPV-positive samples for which PCRs with genotype-specific primers had yielded specific genotype information, there was good concordance with the genotypes assigned to these samples by the BESS-T Base Reader Kit method. Discordance was seen for only 2 of these 15 samples. Sample 20 was found to contain HPV-35 on the basis of the BESS-T Base Reader Kit analysis but had been determined to be HPV-16 positive on the basis of the use of genotype-specific primer pairs. We sequenced the GP5+-GP6+ amplimer from this sample and found it to be identical to the HPV-35 sequence, confirming the result obtained with the BESS-T Base Reader Kit. The isolate in the second sample with a discordant result, sample 28, which had been found to contain HPV-18 on the basis of genotype-specific PCR, could not be genotyped successfully by the BESS-T Base Reader Kit analysis; it was one of the two samples for which there appeared to be evidence that a mixture of at least two HPV genotypes was present in the sample, precluding its successful analysis by genotyping. Of the 12 samples that yielded genotype information by BESS-T Base Reader Kit analysis but that had not yielded genotype information by the genotype-specific PCR analysis (samples 6 to 11, 14, 15, 19, 21, 23, 25, and 29), 3 were determined to contain genotypes that should have been detected by the latter technique (samples 10 and 11 were found by BESS-T Base Reader Kit analysis to contain HPV-16, and sample 29 was found by the BESS-T Base Reader Kit analysis to contain HPV-33; Table 1). Sequence analysis of the amplimer generated from these three samples with GP5+-GP6+ confirmed the accuracy of BESS-T Base Reader Kit analysis (Table 1). Of the remaining nine samples whose isolates were genotyped successfully only by BESS-T Base Reader Kit analysis, seven HPV genotypes not tested for with the genotype-specific primer pairs were detected (HPV type 31, 35, 45, 51, 56, 58, and 59).
We also tested the utility of BESS-T Base Reader Kit analysis for genotyping of isolates in archival material. DNA was extracted from seven paraffin-embedded cervical cancer biopsy specimens and subjected to HPV-specific PCR with the MY09-MY11 primers. Three samples positive for HPV DNA were then analyzed by the BESS-T Base Reader Kit method (Fig. 3C). Isolates in all three samples could be genotyped. Samples 1 and 3 were found to contain HPV-16; sample 2 was found to contain HPV-31.
Application of this new genotyping method to the analysis of large numbers of clinical samples would require fast-throughput screening capabilities. To this end we tested the utility of using an automated capillary DNA sequencer to resolve BESS-T Base Reader Kit cleavage products. BESS-T Base Reader Kit reactions were performed with recombinant HPV type 16, 18, and 31 plasmid templates by using the MY09-MY11 primer pair. The MY11 primer was fluorescently labeled. The amplimer was subjected to cleavage with the uracil N-glycosylase and endonuclease IV mixtures, and the products were resolved on an ABI automated DNA sequencer. The readout from the ABI apparatus for these three reactions is shown in Fig. 4A to C. Each sample gave a peak pattern that was consistent with the deduced T-ladder banding pattern predicted for the regions of the three genomes analyzed. This experiment proved the potential value of using automated DNA sequencing technology for automation of the BESS-T Base Reader Kit HPV genotyping methodology. Using this capillary sequencing system, we analyzed 20 additional clinical samples from an ongoing study of HPV prevalence in North American women. Two examples of this analysis are provided in Fig. 4D and E; both clinical samples were determined to contain HPV-16 DNA. Complete concordance was found between the genotype information gained with the ABI sequencer compared to that obtained by the manual analysis of the same samples according to the experiments described in Fig. 3 (data not shown). That these automated analyses were carried out by single-round PCR, without the need for using nested PCR primers, increases the utility of this technique for large-scale analyses.
|
| |
DISCUSSION |
|---|
|
|
|---|
Establishment of HPV infection status and identification of the HPV genotype in clinical samples are gaining ground as important prognostic indicators in the clinical screening of women and management of those found to be at risk for the development of cervical cancer (2). Combining the existing Pap smear analysis protocol with HPV screening has been proposed as a more definitive method for assessing the risk of an individual for developing cervical cancer. The risks for developing cervical cancer differ greatly between individuals infected with low-risk anogenital HPV genotypes and those infected with high-risk anogenital HPV genotypes (11). For this reason, it will be valuable to know the exact genotype present in clinical samples found to be HPV positive. To date, HPV genotyping studies have largely been limited to epidemiological studies and have used a variety of technologies, some of which are of relatively low resolution and others of which, while of high resolution, are limited in the genotypes that they can identify. In this study we describe a facile method for efficient genotyping of the HPV present in clinical samples.
A value of the BESS-T Base Reader Kit methodology is that it reflects an extension of a preexisting method routinely used for determination of the HPV infection status of clinical samples, i.e., PCR screening with the consensus L1-specific primers MY09-MY11 and/or GP5+-GP6+. The BESS-T Base Reader Kit can be adapted to the analysis of any region of the HPV genome depending upon the choice of primers used in the PCR. The sensitivity and reliability of the BESS-T Base Reader Kit method are the same as those of PCR, the technology upon which it is built. The primary limitation of the BESS-T Base Reader Kit method is in resolving the identities of genotypes in samples containing a mixture of two or more HPVs. When one HPV genotype predominates, its identity but not that of the other genotype(s) present can be determined with the BESS-T Base Reader Kit (e.g., see Table 1, samples 1 and 7). In a mixed sample where no individual genotype predominates, results are ambiguous (e.g., Table 1, samples 23 and 28). The frequency with which clinical samples are found to have mixed infections has not been extensively investigated. Among the 30 coded clinical samples from a prospective study and the 3 archival samples chosen for analysis in this study, 12% (4 of 33) had mixed infections. It would be important that such samples be further analyzed, perhaps by a technique like the line probe assay, if not BESS-T Base Reader Kit analysis of multiple individually cloned HPV DNAs from a given sample.
In comparing the results obtained by the BESS-T Base Reader Kit analysis to those obtained with genotype-specific primers (Table 1), there were several cases of discordance. Consideration of these cases of discordance may provide insights into the strengths and limitations of various genotyping methodologies. In one case, BESS-T Base Reader Kit analysis led to the identification of HPV-35 in sample 20. HPV-16 was detected in the same sample by using genotype-specific primers (Table 1). Sequence analysis of the GP5+-GP6+ amplimer confirmed the BESS-T Base Reader Kit result (Table 1). Perhaps a low-level presence of HPV-16 in the clinical sample in which HPV-35 could be detected with the genotype-specific primers may not have been detectable in the BESS-T Base Reader Kit analysis given the relative abundance of the other viral genome (HPV-35). Were this the case, it points to the previously raised concern that in using the BESS-T Base Reader Kit method with consensus primers, one might not detect HPVs present in patients with mixed infections (an issue of clear relevance to the second case of discordance [sample 28]). Alternatively, HPV-16 may be present at high levels in sample 20, but the region of the viral genome analyzed by the BESS-T Base Reader Kit was not present in the HPV-16 genomes in this clinical sample, for instance, were the HPV-16 genome to have integrated into the cellular genome. In cervical cancers in which high-risk HPV genomes are found to be integrated, deletions within the late region are not uncommon (18). This potential caveat points to the value of analyzing more than one region of the papillomavirus genome by the BESS-T Base Reader Kit method, a viable option given the availability of degenerate primer pairs specific for regions of the HPV genome other than L1 (4, 6). There were three cases of discordance (Table 1, samples 10, 11, and 25) in which the genotype-specific PCR failed to detect HPVs tested for by this technique but in which they were detected by the BESS-T Base Reader Kit method (and confirmed by sequence analysis). The apparently higher sensitivity of the BESS-T Base Reader Kit method may simply reflect the use of nested PCR in the original amplification of the L1 region with degenerate primers compared to the use of a single round of PCR with genotype-specific primers.
The BESS-T Base Reader Kit analysis that we performed led to the detection of single base substitutions at T residues in clinical isolates of certain HPVs. Two examples of this that were confirmed are provided in the cases of samples 11 and 19 (Table 1). In both samples polymorphisms were detected in HPV-16 and HPV-31 on the basis of deviations in the banding pattern observed by BESS-T Base Reader Kit analysis of these samples (Fig. 3B) compared to the deduced T-ladder pattern for the canonical HPV genomes (Fig. 2). These polymorphisms were confirmed upon direct sequence analysis of the amplimer generated with GP5+-GP6+ (Table 1). There is an increasing interest in understanding differences in the pathogenicities of subtypes of high-risk HPV types. The capacity, using our technique, to identify polymorphic markers that distinguish HPV subtypes could be useful in further evaluating the pathogenic properties of subtypes in the context of large-scale prospective or retrospective studies.
The basic advantage of the BESS-T Base Reader Kit method over other genotyping methodologies is that one can assess the genotypes of papillomaviruses in clinical samples in a single-step PCR analysis. This analysis can be achieved by either nested (e.g., Fig. 3) or unnested (Fig. 4) PCR. The BESS-T Base Reader Kit effectively allows one to establish the pattern of T residues in a given sequence (9). In the region of the papillomavirus genomes chosen for analysis in this study, all anogenital papillomaviruses had distinct patterns of T residues on the strand analyzed (Fig. 2), thereby allowing one to determine genotypes unequivocally. As discussed above, verification of the genotype can be provided by BESS-T Base Reader Kit analysis of other regions of the papillomavirus genomes for which there exist degenerate oligonucleotide pairs that permit detection of multiple genotypes. Alternatively, one can perform BESS-T Base Reader Kit analysis of the same region but analyze the opposite strand (i.e., by end labeling the other oligonucleotide, e.g., GP6+ in this study) or use the BESS-G Base Reader Kit, a similar methodology that allows one to establish the G-residue pattern in a given sequence (10). These extensions of the basic methodology described in this study could increase the precision of this genotyping approach where necessary.
The application of the BESS-T Base Reader Kit method or any other method or the genotyping of large numbers of HPV isolates in clinical samples would be greatly enhanced were the method automated. This should be easily achieved with the BESS-T Base Reader Kit method. We were able to make use of an automated DNA sequencing apparatus to generate peak patterns for BESS-T Base Reader Kit reactions of recombinant HPV DNAs cloned into plasmids (Fig. 4A to C). These peak patterns were equivalent to the deduced T-ladder patterns for these test genomes. We also performed a similar automated genotype analysis with clinical isolates. The peak patterns generated with the automated sequencer led to the identification of the same genotypes (for examples, see Fig. 4D and E) identified by the unautomated procedure (data not shown). An added advantage of the automated procedure is the absence of the need to use radioactivity. Preliminary efforts indicate that modification of the ABI sequence analysis program should permit computer-assisted identification of genotypes in clinical samples.
| |
ACKNOWLEDGMENTS |
|---|
We acknowledge Angie Buehl for preparing histopathological sections and Gary Dahl for critical reading of the manuscript.
This study was supported by grants from the American Cancer Society (grant VM164) and the National Institutes of Health (grant CA22443).
| |
FOOTNOTES |
|---|
* Corresponding author. Mailing address: McArdle Laboratory for Cancer Research, 1400 University Ave., Madison, WI 53706. Phone: (608) 262-8533. Fax: (608) 262-2824. E-mail: lambert{at}oncology.wisc.edu.
Present address: MWG Biotech Inc., High Point, NC 27265.
| |
REFERENCES |
|---|
|
|
|---|
| 1. | Chua, K. L., F. Wiklund, P. Lenner, T. Angstrom, G. Hallmans, F. Bergman, M. Sapp, J. Schiller, G. Wadell, A. Hjerpe, and J. Dillner. 1996. A prospective study on the risk of cervical intra-epithelial neoplasia among healthy subjects with serum antibodies to HPV compared with HPV DNA in cervical smears. Int. J. Cancer 68:54-59[CrossRef][Medline]. |
| 2. | Cox, J. T. 1996. Clinical role of HPV testing. Obstet. Gynecol. Clin. N. Am. 23:811-851[CrossRef][Medline]. |
| 3. |
de Roda Husman, A. M.,
J. M. Walboomers,
A. J. van den Brule,
C. J. Meijer, and P. J. Snijders.
1995.
The use of general primers GP5 and GP6 elongated at their 3' ends with adjacent highly conserved sequences improves human papillomavirus detection by PCR.
J. Gen. Virol.
76:1057-1062 |
| 4. | Evander, M., E. Boden, L. Bjersing, E. Rylander, and G. Wadell. 1991. Oligonucleotide primers for DNA amplification of the early regions 1, 6, and 7 from human papillomavirus types 6, 11, 16, 18, 31, and 33. Arch. Virol. 116:221-233[CrossRef][Medline]. |
| 5. |
Evander, M.,
K. Edlund,
E. Boden,
A. Gustafsson,
M. Jonsson,
R. Karlsson,
E. Rylander, and G. Wadell.
1992.
Comparison of a one-step and a two-step polymerase chain reaction with degenerate general primers in a population-based study of human papillomavirus infection in young Swedish women.
J. Clin. Microbiol.
30:987-992 |
| 6. | Evander, M., and G. Wadell. 1991. A general primer pair for amplification and detection of genital human papillomavirus types. J. Virol. Methods 31:239-250[CrossRef][Medline]. |
| 7. | Forslund, O., B. G. Hansson, and B. Bjerre. 1994. Typing of human papillomaviruses by consensus polymerase chain reaction and a non-radioactive reverse dot blot hybridization. J. Virol. Methods 49:129-139[CrossRef][Medline]. |
| 8. |
Gravitt, P. E.,
C. L. Peyton,
R. J. Apple, and C. M. Wheeler.
1998.
Genotyping of 27 human papillomavirus types by using L1 consensus PCR products by a single-hybridization, reverse line blot detection method.
J. Clin. Microbiol.
36:3020-3027 |
| 9. | Hawkins, G. A., and L. M. Hoffman. 1997. Base excision sequence scanning. Nat. Biotechnol. 15:803-804[CrossRef][Medline]. |
| 10. | Hawkins, G. A., and L. M. Hoffman. Rapid DNA mutation identification and fingerprinting using base excision sequence scanning (BESS). Electrophoresis 20:1171-1176. |
| 11. | Howley, P. M. 1996. Papillomavirinae: the viruses and their replication, p. 2045-2109. In B. N. Fields, D. M. Knipe, and P. M. Howley (ed.), Virology, 3rd ed., vol. 2. Lippincott-Raven, Philadelphia, Pa. |
| 12. | Kjellberg, L., Z. Wang, F. Wiklund, K. Edlund, T. Angstrom, P. Lenner, I. Sjoberg, G. Hallmans, K. L. Wallin, M. Sapp, J. Schiller, G. Wadell, C. G. Mahlck, and J. Dillner. 1999. Sexual behaviour and papillomavirus exposure in cervical intraepithelial neoplasia: a population-based case-control study. J. Gen. Virol. 80:391-398[Abstract]. |
| 13. | Kjellberg, L., F. Wiklund, I. Sjoberg, G. Wadell, T. Angstrom, J. Dillner, and C. G. Mahlck. 1998. A population-based study of human papillomavirus deoxyribonucleic acid testing for predicting cervical intraepithelial neoplasia. Am. J. Obstet. Gynecol. 179:1497-1502[CrossRef][Medline]. |
| 14. | Manos, M. M., Y. Ting, D. K. Wright, A. J. Lewis, T. R. Broker, and S. M. Wolinsky. 1989. Use of polymerase chain reaction amplification for the detection of genital human papillomaviruses. Cancer Cells 7:209-214. |
| 15. | Meyers, G., A. Halpem, C. Baker, A. McBride, C. Wheeler, and J. Doorbar (ed.). 1996. L1 alignments, p. II-L1-1-II-L1-67. In Human papillomaviruses 1996: a compilation and analysis of nucleic acid and amino acid sequences. Theoretical Biology and Biophysics, Los Alamos National Laboratory, Los Alamos, N.M. |
| 16. | Pfister, H. 1984. Biology and biochemistry of papillomaviruses. Rev. Physiol. Biochem. Pharmacol. 99:111-181[CrossRef][Medline]. |
| 17. | Schiffman, M. H., N. B. Kiviat, R. D. Burk, K. V. Shah, R. W. Daniel, R. Lewis, J. Kuypers, M. M. Manos, D. R. Scott, M. E. Sherman, R. J. Kurman, M. H. Stoler, A. G. Glass, B. B. Rush, I. Mielzynska, and A. T. Lorincz. 1995. Accuracy and interlaboratory reliability of human papillomavirus DNA testing by hybrid capture. J. Clin. Microbiol. 33:545-550[Abstract]. |
| 18. | Schwarz, E., U. K. Freese, L. Gissmann, W. Mayer, B. Roggenbuck, A. Stremlau, and H. zur Hausen. 1985. Structure and transcription of human papillomavirus sequences in cervical carcinoma cells. Nature 314:111-114[CrossRef][Medline]. |
| 19. | zur Hausen, H. 1991. Human papillomaviruses in the pathogenesis of anogenital cancer. Virology 184:9-13[Medline]. |
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||