Previous Article | Next Article 
Journal of Clinical Microbiology, November 2001, p. 4125-4130, Vol. 39, No. 11
0095-1137/01/$04.00+0 DOI: 10.1128/JCM.39.11.4125-4130.2001
Development and Evaluation of a Fluorogenic
5' Nuclease Assay To Detect and Differentiate between
Ebola Virus Subtypes Zaire and Sudan
Tammy R.
Gibb,*
David
A.
Norwood Jr.,
Neal
Woollen, and
Erik A.
Henchal
Diagnostic Systems Division, United States
Army Medical Research Institute of Infectious Diseases, Fort
Detrick, Maryland 21702-5011
Received 3 April 2001/Returned for modification 12 May
2001/Accepted 19 August 2001
 |
ABSTRACT |
The ability to rapidly recognize Ebola virus infections is critical
to quickly limit further spread of the disease. A rapid, sensitive, and
specific laboratory diagnostic test is needed to confirm outbreaks of
Ebola virus infection and to distinguish it from other diseases that
can cause similar clinical symptoms. A one-tube reverse
transcription-PCR assay for the identification of Ebola virus subtype
Zaire (Ebola Zaire) and Ebola virus subtype Sudan (Ebola Sudan) was
developed and evaluated by using the ABI PRISM 7700 sequence detection
system. This assay uses one common primer set and two differentially
labeled fluorescent probes to simultaneously detect and differentiate
these two subtypes of Ebola virus. The sensitivity of the primer set
was comparable to that of previously designed primer sets, as
determined by limit-of-detection experiments. This assay is unique in
its ability to simultaneously detect and differentiate Ebola Zaire and
Ebola Sudan. In addition, this assay is compatible with
emerging rapid nucleic acid analysis platforms and therefore may prove
to be a very useful diagnostic tool for the control and management of
future outbreaks.
 |
INTRODUCTION |
Ebola virus is a
single-stranded, nonsegmented, negative-sense RNA virus that belongs to
the family Filoviridae. It is one of two members (Ebola
virus and Marburg virus) that are responsible for sporadic epidemics of
hemorrhagic fever in human and nonhuman primates.
Infection with Ebola virus results in rapid disease progression and
high mortality rates. The main route of transmission of filoviruses is
contact with contaminated bodily fluids, such as through improper
needle hygiene, direct contact with infected tissue or fluid samples,
or close contact with infected patients, which are the primary routes
of transmission (1, 2, 5). Consequently, those at greatest
risk for contracting the disease are health care providers and
families, who, in rural African communities, may be the primary care
providers for sick patients. Because of the mode of transmission, high
fatality rates, and the need to institute proper barrier nursing
precautions and public health measures during outbreaks, it is
essential to establish a diagnosis early in the course of the disease.
In regions of Africa where numerous diseases can cause similar clinical
syndromes (Lassa fever, Shigella dysentery, and malaria),
the diagnosis of filoviral infections can present a challenge. During
an Ebola virus outbreak, the ability to establish a rapid diagnosis may help save the lives of patients presenting with treatable diseases such
as Shigella dysentery and malaria. In these instances,
proper triage of patients depends heavily on a rapid and accurate diagnosis.
Assays currently available for the diagnosis of Ebola virus infections
include virus culture, transmission electron microscopy (TEM),
immunohistochemistry, antigen detection enzyme-linked immunosorbent assays (ELISAs), antibody detection ELISAs, and a conventional reverse
transcription-PCR (RT-PCR) (8, 13, 14, 18, 20). Each method has both advantages and disadvantages; however, few assays
that can be used in the field and that are capable of providing a
sensitive, specific, and rapid diagnosis are available. Virus culture
is sensitive but must be performed in a biological safety level
4 laboratory. TEM is a rapid technique (<3 h), but it is usually available only in well-equipped research facilities
(8). Both virus culture and TEM are routinely performed by
reference laboratories. Antibody detection ELISAs are often unreliable
because patients with symptomatic Ebola virus infections often fail to mount a detectable humoral response prior to death (3,
15). Antigen detection ELISAs are adequate for the detection of
Ebola virus infections during the acute stages of infection; however, special precautions must be taken when handling infectious samples. Alternatively, samples can be inactivated with
-propiolactone. To
date, the most rapid and potentially deployable assay that also has
good clinical sensitivity is based on conventional RT-PCR.
Conventional RT-PCR is a more sensitive method than antigen detection
ELISAs and has the advantage of rendering samples noninfectious before
use. However, current RT-PCR assays are not capable of detecting all
known subtypes of Ebola virus, and they are not compatible with
emerging rapid nucleic acid analysis systems (20). Several
rapid nucleic acid analysis systems use a fluorogenic probe-based assay
to monitor the accumulation of PCR product in real time. With these
assays, it is possible to detect a positive sample in 1 h or less.
Fluorogenic probes are not incorporated into the design of conventional
RT-PCR assays; therefore, these assays are not capable of being
monitored on real-time nucleic acid analysis systems. Instead,
following RT-PCR, which is routinely performed as two separate steps
(an RT step and a PCR step), samples must be analyzed by gel
electrophoresis. The total assay time for conventional RT-PCR,
including data analysis by gel electrophoresis, can be 3 to 4 h.
The purpose of the present study was to demonstrate a highly sensitive,
specific, and rapid assay that would be compatible with emerging rapid
nucleic acid analysis platforms.
 |
MATERIALS AND METHODS |
Viral growth, purification, and titers.
Ebola, Marburg, and
Lassa virus strains were propagated in Vero E6 cells. Crimean-Congo
hemorrhagic fever and measles (Edmonston strain) viruses were
propagated in Vero cells. Vesicular stomatitis virus was propagated in
BHK cells. Upon visualization of 60 to 70% cytopathic effects, the
supernatant was harvested and clarified by centrifugation. For Ebola,
Marburg, and measles virus purification, the supernatant was clarified
by centrifugation at 1,500 × g for 15 min in a Sorvall
centrifuge. Polyethylene glycol (PEG; average molecular weight [MW],
8,000) and NaCl were added to the supernatant to final concentrations
of 7.5% (wt/vol) and 0.5 M, respectively. Virus was allowed to
precipitate for 4 h at 4°C. Precipitated virus was pelleted by
centrifugation at 10,000 × g for 30 min and suspended
in 5 ml of TNE (10 mM Tris-HCl [pH 8.0], 100 mM NaCl, 1 mM EDTA [pH
8.0]). Suspended virus was then concentrated by ultracentrifugation at
27,000 rpm in a SW28 rotor through a 20 to 60% (wt/wt) sucrose
gradient in TNE (10). For Crimean-Congo hemorrhagic fever
virus, the supernatant material was precipitated with 8% (wt/vol) PEG
containing 2.3% (wt/vol) NaCl for 3 h at 4°C. The precipitate
was pelleted, suspended in TNE, and overlaid onto a 15 to 65% (wt/wt)
sucrose gradient in TNE. The gradients were centrifuged at 40,000 rpm
in a SW41 rotor for 1.5 h at 4°C. Fractions (1 ml) of the
gradient were analyzed directly by sodium dodecyl
sulfate-polyacrylamide gel electrophoresis as described previously
(11). For Lassa virus purification, the supernatant was
clarified in a Sorvall centrifuge at 8,000 rpm in a GSA rotor. Seven
percent (wt/vol) PEG (average MW, 6,000) and 2.3% (wt/vol) NaCl were
added to the supernatant. The virus was then allowed to precipitate for
3 h at 4°C. The precipitate was then purified through a
discontinuous 10 to 40% Renografin gradient in an SW41 rotor at 37,000 rpm for 75 min. The visible virus band was harvested, diluted in 3 ml
of TNE, and purified through a continuous 10 to 50% Renografin
gradient in an SW41 rotor at 30,000 rpm overnight. The virus was
harvested, pelleted by centrifugation in an SW41 rotor at 38,000 rpm
for 45 min, and suspended in 2 ml of TNE (P. B. Jahrling,
unpublished protocol). For vesicular stomatitis virus purification,
cell culture supernatants were clarified by centrifugation at
10,000 × g for 30 min. PEG (average MW, 8,000) and
NaCl were added to the clarified supernatant to final
concentrations of 7 and 2.3%, respectively. Virus was precipitated
overnight at 4°C. The precipitated virus was then pelleted by
centrifugation at 10,000 × g for 30 min, resuspended
in Dulbecco's phosphate-buffered saline (PBS) and then purified by
centrifugation through a 20 to 60% (wt/wt) sucrose density gradient
for 3.5 h at 100,000 × g. Sucrose solutions were
prepared in Hank's balanced salt solution without NaHCO3
containing 0.02 M
N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid buffer (pH 7.2) (16).
The titers of the filoviruses were determined by performing plaque
assays on Vero E6 cells as described previously (17). Briefly, viral stock was serially diluted in Eagle's minimum essential medium (EMEM) with nonessential amino acids (NEAA), adsorbed onto confluent Vero E6 cells in 12-well dishes, incubated for 1 h at 37°C, and covered with an agarose overlay. A 1:5,000 dilution of
neutral red in buffered saline solution was added 7 days later, and
plaques were counted the next day.
Primer and probe design.
The characteristics of selected
primer and probe sets are listed in Table
1. The sequences of the Zaire and Sudan
subtypes of Ebola virus (Ebola Zaire and Ebola Sudan,
respectively) were aligned by using the DNA Star MegAlign
software. After careful study of the aligned sequences, an 111-bp
region of the glycoprotein (GP) was targeted for primer and
probe development. In order to achieve efficient amplification of the
Ebola Zaire and Ebola Sudan templates, degenerate primers were
designed. The EBOGP-1D primer and double-probe set (Table 1) was
designed by evaluating the Ebola virus GP gene (GenBank Accession
numbers U77384 [Ebola virus subtype Gabon-94], U31033 [Ebola
Zaire], U28134 [Ebola Sudan, Boniface strain], U23069 [Ebola Sudan,
Maleo strain], U23417 [Ebola virus subtype Reston, Siena strain])
with Primer Express Software (Applied Biosystems, Foster City, Calif.).
The primer and double-probe set was designed to meet the guidelines recommended by Applied Biosystems. In brief, the primers were designed
with melting temperatures (Tms) between 58 and
60°C. Probes were designed to have a Tm at
least 7 to 10°C higher than the Tms of the
primers. The presence of a guanine at the 5' ends of the probes was
avoided, and the amplicons were designed to be less than 200 bp in
length. Primer and probe dimers, hairpins, stem-loops, and false
priming sites were avoided.
Two differentially labeled fluorogenic probes that would hybridize to
the template between the EBOGP-1D PCR primers were designed.
An Ebola
Zaire-specific probe which has a covalently linked fluorescent
reporter
dye, 6-carboxyfluorescein (FAM), attached to the 5' end
and a quencher
dye, 6-carboxytetramethylrhodamine (TAMRA), covalently
attached to its
3' end was designed to recognize the Ebola Zaire
template. An Ebola
Sudan-specific probe which has a covalently
linked fluorescent reporter
dye, VIC, attached to the 5' end and
a quencher dye, TAMRA,
covalently attached to its 3' end was designed
to recognize the Ebola
Sudan template. Depending on the template
present in the sample, either
the FAM-labeled Ebola Zaire-specific
probe or the VIC-labeled Ebola
Sudan-specific probe would generate
a fluorescent signal. These signals
could be distinguished from
one another on the basis of their emission
spectra.
The sequences of the primers and probes are as follows:
5'-TGGGCTGAAAAYTGCTACAATC-3' for the EBOGP-1D forward primer
and 5'-CTTTGTGMACATASCGGCAC-3'
for the EBOGP-1D reverse
primer. The probe sequences are 5'-CTACCAGCAGCGCCAGACGG-3'
for EBOGP-1DZPrb and 5'-TTACCCCCACCGCCGGATG-3' for
EBOGP-1DSPrb.
Fluorogenic 5' nuclease assays.
The RT-PCR assays were
performed on an ABI PRISM 7700 sequence detection system with an
Applied Biosystems TaqMan EZ RT-PCR kit in accordance with the
manufacturer's instructions. Thermocycling conditions for the EBOGP-1D
primer and double-probe set were as follows: 55°C for 45 min and
94°C for 1 min followed by 40 cycles at 94°C for 15 s and 60°C
for 30 s. The final concentrations used in the 50-µl reaction
mixture were as follows: 0.5 µM each primer, 0.2 µM each probe, 5 U
of rTth enzyme, 300 µM deoxynucleotide triphosphates, 1×
Applied Biosystems TaqMan RT-PCR buffer containing the passive
reference dye ROX, and 2.5 mM manganese acetate. The total
assay time on the ABI PRISM 7700 sequence detection system was
approximately 2 h.
Conventional RT-PCR assays.
Previously published primer sets
(Table 1) were tested by using the Applied Biosystems EZ
rTth RNA PCR kit in accordance with the manufacturer's
instructions. Thermocycling conditions for each set were published
previously (20). The final concentrations used in the
50-µl reaction mixture were as follows: 0.5 µM each primer, 5 U of
rTth enzyme, 300 µM deoxynucleotide triphosphates, 1×
Applied Biosystems EZ buffer, and 2.5 mM manganese acetate. All assays
were performed on a PTC 100 thermocycler (MJ Research, Waltham, Mass.).
Direct analysis and detection of RT-PCR-amplified products on
agarose gels.
Ten-microliter aliquots of the RT-PCR products were
electrophoresed on 4% agarose gels (NuSieve; FMC BioProducts,
Rockland, Maine) in Tris-borate-EDTA buffer (TBE) containing 1 µg of ethidium bromide per ml. The DNA bands were visualized with an
imaging system (Alpha Inotech Corporation, San Leandro, Calif.).
Sequencing of RT-PCR products.
To confirm the identities of
the PCR products, amplicons from RT-PCR were sequenced with dye-labeled
terminators and by cycle sequencing (Taq Prism kit; Applied
Biosystems, Foster City, Calif.). The products from the
sequencing reactions were analyzed on an Applied Biosystems 377 sequencer. The sequences were then identified with the National Center
for Biotechnology Information's Basic Local Alignment Search Tool
(BLAST; http://www.ncbi.nlm.nih.gov/BLAST/).
LOD assays.
To determine the limits of detection (LODs) of
the numbers of PFU, serial 10-fold dilutions of sucrose-purified Ebola
virus seeds (Zaire and Sudan subtypes) were prepared in 1 ml of EMEM with NEAA. Control samples lacking template were prepared with virus-free EMEM with NEAA. One hundred microliters of each dilution was
placed in Trizol LS (Gibco BRL, Gaithersburg, Md.), and RNA was
isolated in accordance with the manufacturer's instructions. Briefly,
chloroform was added to the virus-Trizol LS mixture, the mixture was
centrifuged, and the aqueous phase containing the RNA was harvested.
The RNA was then precipitated with isopropanol, washed with 75%
ethanol, and resuspended in 100 µl of RNase-free water. One
microliter of each RNA preparation was used in subsequent TaqMan
assays. To determine the number of PFU per dilution, serial 10-fold
dilutions were assayed on Vero E6 cells as described above. The LOD was
defined as the last dilution in the fluorogenic 5' nuclease assays in
which the threshold cycle (CT value) was less than 40.
To determine LODs by mass, sucrose-purified virus was placed in Trizol
LS (Gibco BRL) and the RNA was isolated as described
above. The RNA was
quantitated by spectrophotometry, and serial
10-fold dilutions
containing from 1 ng to 10 fg were prepared.
One microliter of
each dilution was used in subsequent TaqMan
and conventional RT-PCR
assays. All assays were performed in triplicate.
The LODs of the newly
designed Taqman assay were compared to the
LODs of previously designed
Ebola primers (Table
1).
Spiked clinical samples.
Whole blood, plasma, and serum were
collected from nonhuman primates. One hundred microliters each of
blood, plasma, serum, and PBS was spiked with known amounts (ranging
from 78, 125 to 25 PFU) of sucrose-purified Ebola Zaire. One hundred
microliters of EMEM with NEAA was added to each spiked sample, and each
sample was placed in the appropriate volume of Trizol LS (Gibco BRL). The RNA was isolated as described above and was resuspended in a volume
of 20 µl. Five microliters of each RNA preparation was used in
subsequent TaqMan assays.
Cross-reactivity panel.
To evaluate for potential
cross-reactivity of the EBOGP-1D primer-probe set, RNA was isolated
from genetically related viruses (vesicular stomatitis virus, measles
virus, and Marburg virus strains Musoke, Ravn, and Ci67) and other
hemorrhagic fever viruses (Lassa virus and Crimean-Congo hemorrhagic
fever virus). RNAs were extracted from purified seeds of these viruses
with Trizol LS, as described above. One nanogram of each viral template
was used for cross-reactivity testing. The cross-reactivity panel was
blinded by an independent investigator who assigned random numbers to
each sample.
 |
RESULTS |
TaqMan primer-probe design.
Two hundred sets of primers and
probes specific for a highly conserved region of the Ebola Zaire and
Ebola Sudan GP gene were generated by using Primer Express software.
The EBOGP-1D primer and double-probe set was chosen on the basis of
guidelines recommended by Applied Biosystems, outlined above.
The primer and double-probe set chosen, EBOGP-1D, was designed to
amplify a 111-bp region of the GP gene. The EBOGP-1D primers are
degenerate primers designed to amplify both Ebola Zaire and Ebola
Sudan. Because of sequence variability, degenerate primers were
required to achieve efficient amplification of both templates. The
probes specific for each virus (Ebola Zaire or Ebola Sudan) were
designed so that there was 100% homology with the appropriate
template. The probes were designed for the same sequence of the Ebola
virus GP gene; however, the strains differed by seven nucleotides in
this region.
Specificity of a double-probe assay for Ebola Zaire and Ebola Sudan
templates.
The sequence variability between the two subtypes of
Ebola virus (>40%) necessitated the design of a degenerate primer set to efficiently amplify both targets (18, 19). The
FAM-labeled Ebola Zaire probe was specific for Ebola Zaire (Fig.
1). Likewise, the VIC-labeled Ebola Sudan
probe was specific for Ebola Sudan (Fig.
2). If we observed a
CT value less than 40 with the FAM-labeled probe, we positively identified the template as Ebola Zaire. Likewise, if we observed a CT value less than 40 with the
VIC-labeled probe, we positively identified the template as Ebola Sudan
(Fig. 1 and 2).

View larger version (125K):
[in this window]
[in a new window]
|
FIG. 1.
LOD of EBOGP-1D TaqMan assay for Ebola Zaire with a
FAM-labeled Ebola Zaire-specific probe (A) and a VIC-labeled Ebola
Sudan-specific probe (B). Total RNA isolated from serial dilutions of
sucrose-purified virus was used as the template. Each assay was
performed in triplicate. The graphs depict amplification plots for the
Ebola Zaire template obtained with both probes. Amplification plots
show that the VIC-labeled Ebola Sudan-specific probe does not
cross-react with the Ebola Zaire template. Rn, change in
fluorescence.
|
|

View larger version (125K):
[in this window]
[in a new window]
|
FIG. 2.
LOD of EBOGP-1D TaqMan Assay for Ebola Sudan with a
VIC-labeled Sudan specific probe (A) and a FAM-labeled Ebola
Zaire-specific probe (B). Total RNA isolated from serial dilutions of
sucrose-purified virus was used as the template. Each assay was
performed in triplicate. The graphs depict amplification plots for the
Ebola Sudan template obtained with both probes. Amplification plots
show that the FAM-labeled Ebola Zaire-specific probe does not
cross-react with the Ebola Sudan template. Rn, change in
fluorescence.
|
|
LOD experiments: assay sensitivity.
The EBOGP-1D primer and
double-probe set was as sensitive or more sensitive than previously
designed primer sets intended for use in conventional RT-PCR assays
(Table 1). The EBOGP-1D primer-probe set was able to detect 10 fg and 8 PFU of purified Ebola Zaire RNA and infectious virus, respectively
(Table 1 and Fig. 1A), and 100 fg and 3 PFU of purified Ebola Sudan RNA
and infectious virus, respectively (Table 1 and Fig. 2A). Previously designed primer sets (Table 1) for use in conventional RT-PCR assays were able to detect 10 fg and 8 PFU (ZAI-NP1/NP2 and
FILOA/FILOB) or 100 pg and 680 PFU (EBOGP1/2) of purified Ebola Zaire
RNA and infectious virus, respectively. These same primer sets detected 1 pg and 74 PFU (FILOA/FILOB) or 100 pg and 770 PFU (EBOGP1/2) of Ebola
Sudan RNA or infectious virus, respectively. ZAI-NP1/NP2 was not able
to detect Ebola Sudan (Table 1). All control samples lacking template
were negative.
Assay specificity.
Several genetically related viruses
and other hemorrhagic fever viruses were used to determine the
cross-reactivity of the EBOGP-1D primer and double-probe set. By using
TaqMan chemistry, the EBOGP-1D primer and double-probe set detected
Ebola Zaire and Ebola Sudan RNAs; however, it did not detect any of the
genetically related or other hemorrhagic fever viruses (Table
2). When examined by gel electrophoresis,
the EBOGP-1D primer set also amplified Ebola virus subtype Reston RNA.
The amplification efficiency of Ebola virus subtype Reston was not as
great as that for Ebola Zaire or Ebola Sudan. EBOGP-1D was able to
detect only 1 ng of subtype Reston RNA. Ebola virus subtype Reston was
not detected by fluorescence during TaqMan assays. The FILOA/FILOB
primer set was able to detect Ebola Zaire, Ebola Sudan, and Ebola virus
subtype Ivory Coast (a very weak amplicon was observed with 1 ng of
Ebola virus subtype Ivory Coast RNA); however, it also amplified
Marburg virus strains Musoke and Ci67. ZAI-NP1/NP2 detected only Ebola Zaire. Therefore, the FILOA/FILOB primer set was not specific for Ebola
Zaire or Ebola Sudan and the ZAI-NP1/NP2 primer set was capable of
detecting only Ebola Zaire (Table 2). The previously designed EBO-GP1/2
primer set amplified Ebola virus subtypes Zaire, Sudan, and Reston. The
amplification efficiency of the EBOGP1/2 primer set was weak with the
Ebola virus subtype Reston and Ebola virus subtype Ivory Coast
templates. The LOD for EBOGP1/2 with the subtype Reston and Ivory Coast
templates was 1 ng (data not shown).
Assay performance in clinical matrices.
The performance of the
EBOGP-1D TaqMan assay in clinical matrices was tested by spiking whole
blood, serum, and plasma from non-human primates with known amounts of
Ebola Zaire (ranging from 78,125 to 25 PFU). PBS was spiked with virus
as a control. The sensitivity of the assay in clinical matrices was
similar to that observed in PBS, with 5 PFU being the LOD (Table
3).
 |
DISCUSSION |
Here we have reported on the development and evaluation of a
fluorogenic double-probe-based, one-step RT-PCR assay on the ABI PRISM
7700 sequence detection system for the identification of Ebola Zaire
and Ebola Sudan infections. This assay is based on the 5' nuclease
assay, which exploits the 5' nuclease activity of rTth
polymerase to cleave a nonextendable, dual-labeled fluorogenic probe
that is annealed to the target sequence during amplification (4,
7, 12). We chose the GP gene of Ebola virus as an assay target
for several reasons. First, the GP protein of Ebola virus is required
for entry into cells. Second, the membrane-bound GP of Ebola virus is
reported to play a central role in the virus-mediated cytotoxicity of
endothelial cells and therefore appears to be an important virulence
factor of Ebola virus (21). Finally, sequence analysis of
the GP genes of Ebola Zaire and Ebola Sudan revealed that regions
within this gene would permit the design of a primer-probe set on the
basis of the guidelines set forth by Applied Biosystems. This assay has
several advantages over the conventional RT-PCR assays used to detect
Ebola virus. First, the use of a fluorogenic probe results in an
increased level of specificity compared to that of conventional
RT-PCR. The EBOGP-1D primer and double-probe set was specific for
Ebola Zaire and Ebola Sudan when it was tested in a blinded
cross-reactivity panel (Table 2). In contrast, a previously designed
primer-probe set (FILOA/FILOB) amplified two of three Marburg virus
strains tested and therefore lacked the specificity of the EBOGP-1D
primer and double-probe set (Table 2). ZAI-NP1/NP2 was capable of
identifying only Ebola Zaire. Second, this assay provides the
capability of simultaneously detecting and differentiating two of the
three subtypes of Ebola virus that are pathogenic for humans. This
unique feature will provide public health officials with an assay that
can not only identify an Ebola virus outbreak but also give them the
information they need to predict probable mortality rates and the
severities of epidemics. Ebola Zaire infections traditionally result in
higher fatality rates during an outbreak compared to the fatality rates that result from Ebola Sudan infections. Third, the one-tube
fluorogenic RT-PCR assay is compatible with emerging rapid nucleic acid
analysis platforms (6). These new platforms are capable of
performing both thermocycling and fluorescence detection in real time.
Sources of these instruments include Applied Biosystems, Roche
Diagnostics (Indianapolis, Ind.), Idaho Technologies (Salt Lake City,
Utah), Cepheid (Sunnyvale, Calif.), and Bio-Rad (Hercules, Calif.).
With the more rapid thermocycling instruments, i.e., Lightcycler (Roche Molecular Systems), the Ruggedized Advanced Pathogen Identification Device (R.A.P.I.D.; Idaho Technologies), or the SmartCycler
(Cepheid), it is reasonable to assume that once a sample is received
and processed, a definitive diagnosis can be made within 20 to 40 min
(9). In addition, the use of this technology in field
laboratories has become a reality now that instruments such as
the R.A.P.I.D. and SmartCycler XC instruments, which have been
specifically designed for use by field medical laboratories, have
become available (9).
In order to obtain an early diagnosis and contain future outbreaks of
Ebola hemorrhagic fever, it will be necessary to implement rapid
diagnostic assays in laboratories throughout Africa. These assays must
be simple to perform, accurate, and reproducible. Transfer of the newly
designed fluorogenic 5' nuclease assay described in this report to
rapid nucleic acid analysis platforms would be a first step toward
providing public health authorities in Africa with a tool to help
diagnose and contain possible outbreaks.
This assay will allow public health officials to detect two of
the three Ebola virus subtypes recognized to be pathogenic for humans.
The sequence divergence among Ebola virus subtypes Zaire, Sudan, and
Ivory Coast prevented the design of a primer set that could efficiently
amplify all three strains. Therefore, future developments should
include the design of an assay that identifies Ebola virus subtype
Ivory Coast. Successful multiplexing of a newly designed Ebola virus
subtype Ivory Coast assay with the EBOGP-1D assay would provide the
capability of detecting and differentiating all known Ebola virus
subtypes that are pathogenic for humans. In addition, the design of a
rapid detection assay that is capable of detecting all known strains of
filoviruses would provide a screening tool for differentiation of
filoviral hemorrhagic fevers from other more common diseases that occur throughout regions of Africa. Future developments that produce a
"dried-down" chemistry for RT-PCR (making the addition of water and
sample the only reagents needed for performance of the fluorogenic RT-PCR assay) should make this assay even easier to use in the field
and would provide a valuable diagnostic capability that would enhance
future outbreak investigations.
 |
ACKNOWLEDGMENTS |
We thank Deanna Bridge, Bill Hurtle, Steven Kerby, and Brian
Kearney for excellent technical assistance. We also thank David Shoemaker and George Ludwig for helpful suggestions and critical input
in the preparation of the manuscript. We are especially indebted to
George Ludwig for providing Lassa virus, Crimean-Congo hemorrhagic
fever virus, measles virus, and vesicular stomatitis virus seeds for
growth and purification.
 |
FOOTNOTES |
*
Corresponding author. Present address: SBCCOM, building
#3150, Edgewood Area, Aberdeen Proving Ground, MD 21010. Phone: (410) 436-7831. Fax: (410) 436-2081. E-mail:
Tammy.Gibb{at}SBCCOM.APGEA.ARMY.MIL.
 |
REFERENCES |
| 1.
|
Anonymous.
1978.
Ebola haemorrhagic fever in Sudan, 1976. Report of a WHO/International Study Team.
Bull. W. H. O.
56:247-270[Medline].
|
| 2.
|
Anonymous.
1978.
Ebola haemorrhagic fever in Zaire, 1976.
Bull. W. H. O.
56:271-293[Medline].
|
| 3.
|
Baize, S.,
E. M. Leroy,
M. C. Georges-Courbot,
M. Capron,
J. Lansoud-Soukate,
P. Debre,
S. P. Fisher-Hoch,
J. B. McCormick, and A. J. Georges.
1999.
Defective humoral responses and extensive intravascular apoptosis are associated with fatal outcome in Ebola virus-infected patients.
Nat. Med.
5:423-426[CrossRef][Medline].
|
| 4.
|
Bassler, H. A.,
S. J. Flood,
K. J. Livak,
J. Marmaro,
R. Knorr, and C. A. Batt.
1995.
Use of a fluorogenic probe in a PCR-based assay for the detection of Listeria monocytogenes.
Appl. Environ. Microbiol.
61:3724-3728[Abstract].
|
| 5.
|
Centers for Disease Control and Prevention.
1995.
Update: management of patients with suspected viral hemorrhagic fever United States.
JAMA
274:374-375[Abstract/Free Full Text].
|
| 6.
|
Espy, M. J.,
J. R. Uhl,
P. S. Mitchell,
J. N. Thorvilson,
K. A. Svien,
A. D. Wold, and T. F. Smith.
2000.
Diagnosis of herpes simplex virus infections in the clinical laboratory by LightCycler PCR.
J. Clin. Microbiol.
38:795-799[Abstract/Free Full Text].
|
| 7.
|
Eun, A. J.,
M. Seoh, and S. Wong.
2000.
Simultaneous quantitation of two orchid viruses by the TaqMan real-time RT-PCR.
J. Virol. Methods
87:151-160[CrossRef][Medline].
|
| 8.
|
Geisbert, T. W., and P. B. Jahrling.
1995.
Differentiation of filoviruses by electron microscopy.
Virus Res.
39:129-150[CrossRef][Medline].
|
| 9.
|
Henchal, E. A.,
J. D. Teska,
G. V. Ludwig,
D. R. Shoemaker, and J. W. Ezell.
2001.
Current laboratory methods for biological threat agent identification.
Clin. Lab. Med.
21:7.1-7.13.
|
| 10.
|
Hevey, M.,
D. Negley,
J. Geisbert,
P. Jahrling, and A. Schmaljohn.
1997.
Antigenicity and vaccine potential of Marburg virus glycoprotein expressed by baculovirus recombinants.
Virology
239:206-216[CrossRef][Medline].
|
| 11.
|
Hodgsen, L.
1992.
The sequence, genomic organization, and expression of the small genomic segment of Crimean Congo hemorrhagic fever virus for the potential use as a diagnostic antigen.
Hood College, Frederick, Md.
|
| 12.
|
Holland, P. M.,
R. D. Abramson,
R. Watson, and D. H. Gelfand.
1991.
Detection of specific polymerase chain reaction product by utilizing the 5'-3' exonuclease activity of Thermus aquaticus DNA polymerase.
Proc. Natl. Acad. Sci. USA
88:7276-7280[Abstract/Free Full Text].
|
| 13.
|
Ksiazek, T. G.,
P. E. Rollin,
P. B. Jahrling,
E. Johnson,
D. W. Dalgard, and C. J. Peters.
1992.
Enzyme immunosorbent assay for Ebola virus antigens in tissues of infected primates.
J. Clin. Microbiol.
30:947-950[Abstract/Free Full Text].
|
| 14.
|
Leroy, E. M.,
S. Baize,
C. Y. Lu,
J. B. McCormick,
A. J. Georges,
M. C. Georges-Courbot,
J. Lansoud-Soukate, and S. P. Fisher-Hoch.
2000.
Diagnosis of Ebola haemorrhagic fever by RT-PCR in an epidemic setting.
J. Med. Virol.
60:463-467[CrossRef][Medline].
|
| 15.
|
Leroy, E. M.,
S. Baize,
V. E. Volchkov,
S. P. Fisher-Hoch,
M. C. Georges-Courbot,
J. Lansoud-Soukate,
M. Capron,
P. Debre,
J. B. McCormick, and A. J. Georges.
2000.
Human asymptomatic Ebola infection and strong inflammatory response.
Lancet
355:2210-2215[CrossRef][Medline].
|
| 16.
|
Ludwig, G. V.,
J. P. Kondig, and J. F. Smith.
1996.
A putative receptor for Venezuelan equine encephalitis virus from mosquito cells.
J. Virol.
70:5592-5599[Abstract/Free Full Text].
|
| 17.
|
Moe, J. B.,
R. D. Lambert, and H. W. Lupton.
1981.
Plaque assay for Ebola virus.
J. Clin. Microbiol.
13:791-793[Abstract/Free Full Text].
|
| 18.
|
Peters, C. J.,
A. Sanchez,
P. E. Rollin,
T. G. Ksiazek, and F. A. Murphy.
1996.
Filoviridae: Marburg and Ebola viruses, p. 1161-1176.
In
B. N. Fields, D. M. Knipe, P. M. Howley, et al. (ed.), Fields Virology, 3rd ed. Lippincott-Raven Press, Philadelphia, Pa.
|
| 19.
|
Sanchez, A.,
M. P. Kiley,
B. P. Holloway, and D. D. Auperin.
1993.
Sequence analysis of the Ebola virus genome: organization, genetic elements, and comparison with the genome of Marburg virus.
Virus Res.
29:215-240[CrossRef][Medline].
|
| 20.
|
Sanchez, A.,
T. G. Ksiazek,
P. E. Rollin,
M. E. Miranda,
S. G. Trappier,
A. S. Khan,
C. J. Peters, and S. T. Nichol.
1999.
Detection and molecular characterization of Ebola viruses causing disease in human and nonhuman primates.
J. Infect. Dis.
179(Suppl. 1):S164-S169.
|
| 21.
|
Yang, Z. Y.,
H. J. Duckers,
N. J. Sullivan,
A. Sanchez,
E. G. Nabel, and G. J. Nabel.
2000.
Identification of the Ebola virus glycoprotein as the main viral determinant of vascular cell cytotoxicity and injury.
Nat. Med.
6:886-889[CrossRef][Medline].
|
Journal of Clinical Microbiology, November 2001, p. 4125-4130, Vol. 39, No. 11
0095-1137/01/$04.00+0 DOI: 10.1128/JCM.39.11.4125-4130.2001
This article has been cited by other articles:
-
Muller, S., Moller, P., Bick, M. J., Wurr, S., Becker, S., Gunther, S., Kummerer, B. M.
(2007). Inhibition of Filovirus Replication by the Zinc Finger Antiviral Protein. J. Virol.
81: 2391-2400
[Abstract]
[Full Text]
-
Saijo, M., Niikura, M., Ikegami, T., Kurane, I., Kurata, T., Morikawa, S.
(2006). Laboratory Diagnostic Systems for Ebola and Marburg Hemorrhagic Fevers Developed with Recombinant Proteins. CVI
13: 444-451
[Full Text]
-
Ikegami, T., Niikura, M., Saijo, M., Miranda, M. E., Calaor, A. B., Hernandez, M., Acosta, L. P., Manalo, D. L., Kurane, I., Yoshikawa, Y., Morikawa, S.
(2003). Antigen Capture Enzyme-Linked Immunosorbent Assay for Specific Detection of Reston Ebola Virus Nucleoprotein. CVI
10: 552-557
[Abstract]
[Full Text]
-
Drosten, C., Gottig, S., Schilling, S., Asper, M., Panning, M., Schmitz, H., Gunther, S.
(2002). Rapid Detection and Quantification of RNA of Ebola and Marburg Viruses, Lassa Virus, Crimean-Congo Hemorrhagic Fever Virus, Rift Valley Fever Virus, Dengue Virus, and Yellow Fever Virus by Real-Time Reverse Transcription-PCR. J. Clin. Microbiol.
40: 2323-2330
[Abstract]
[Full Text]
-
Mackay, I. M., Arden, K. E., Nitsche, A.
(2002). Real-time PCR in virology. Nucleic Acids Res
30: 1292-1305
[Abstract]
[Full Text]