This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Everts, R. J.
Right arrow Articles by Reller, L. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Everts, R. J.
Right arrow Articles by Reller, L. B.

 Previous Article  |  Next Article 

Journal of Clinical Microbiology, September 2001, p. 3393-3394, Vol. 39, No. 9
0095-1137/01/$04.00+0   DOI: 10.1128/JCM.39.9.3393-3394.2001
Copyright © 2001, American Society for Microbiology. All rights reserved.

Contamination of Catheter-Drawn Blood Cultures

Richard J. Everts,1 Emily N. Vinson,1 Paul O. Adholla,1 and L. Barth Reller1,2,3,*

Clinical Microbiology Laboratory,1 Duke University Medical Center, and Departments of Medicine2 and Pathology,3 Duke University School of Medicine, Durham, North Carolina 27710

Received 12 October 2000/Returned for modification 1 March 2001/Accepted 19 June 2001


    ABSTRACT
Top
Abstract
Text
References

To assess the risk of contamination, we reviewed retrospectively 1,408 matched pairs of simultaneous catheter-drawn and venipuncture blood cultures. Catheter-drawn cultures were equally likely to be truly positive (14.4 versus 13.7%) but more likely to be contaminated (3.8 versus 1.8% [P = 0.001]). Direct venipuncture cultures are preferred.


    TEXT
Top
Abstract
Text
References

Contamination of blood cultures causes diagnostic confusion and sometimes leads to unnecessary use of antimicrobial agents. Previous studies comparing contamination of blood drawn through an intravascular catheter with simultaneous direct venipuncture have shown mixed results and included small numbers of patients (1-5, 7-9). To conduct a more-comprehensive comparison of the frequencies of contamination for these two collection methods, we undertook a 2-year retrospective study at a tertiary-care medical center.

Using a computerized database, we identified retrospectively all samples submitted for blood culture from adult or pediatric patients at our hospital between January 1997 and December 1998. From these samples, we identified matched pairs of blood cultures, each consisting of one sample labeled as being taken through an intravascular catheter and the other labeled as being taken by direct venipuncture, both of which were collected from the same patient within a 20-min time span. The specific type of intravascular catheter used was determined from the clinical notes if the label did not contain this information. During the study period, blood culture collection had been undertaken by various nursing and medical staff without standardization of technique. Blood for culture was inoculated into media for processing in a BACTEC 9240 or BacT/ALERT automated blood culture system and incubated either until microbial growth was detected or for 5 days; isolates from positive bottles were identified by standard techniques.

Each positive blood culture isolate was categorized by either an adult or pediatric infectious diseases or medical microbiology physician as clinically significant, indeterminate, or a contaminant. This assessment of significance was based on the probability of each microorganism being a skin contaminant, the number of independently collected positive and negative blood cultures in an episode for a patient, the results of other concurrent microbiology tests (e.g., culture of other samples), and the compatibility of the patient's actual clinical features with typical features of infection with that microorganism as described previously by our group (10). An episode was defined as a period beginning with the first positive blood culture and ending when 7 days (2 days for coagulase-negative staphylococci) had passed without another positive blood culture with the same microorganism, regardless of whether negative cultures were drawn in the intervening days (6, 10). Blood cultures yielding one or more contaminants and one or more truly bacteremic organisms were counted under both categories. We calculated and compared true bloodstream infection rates and contamination rates for matched pairs of catheter-drawn and direct venipuncture samples. The background contamination rates from contemporaneous pediatric and adult studies at our hospital were 2.4% (L. B. Reller, P. O. Adholla, and S. Mirrett Abstr. 98th Gen. Mtg. Am. Soc. Microbiol., abstr. C341, 1998) to 3.5% (6).

From a total of 71,109 blood cultures submitted to the clinical microbiology laboratory during the 2-year period, we identified and analyzed 1,408 pairs of concurrent catheter-drawn and venipuncture samples. Overall true bloodstream infection and contamination rates are presented in Table 1; the higher rate of contamination of cultures collected by intravascular catheter was statistically significant (P = 0.001 by the chi-squared test). Contamination rates for individual intravascular catheter types were as follows: implantable ports (e.g., Port-a-cath), 7 of 166 (4.2%); subcutaneous tunneled and cuffed central venous catheters (e.g., Hickman), 21 of 767 (2.7%); noncuffed, nontunneled central venous catheters, 16 of 245 (6.5%); unspecified central venous catheters, 0 of 31; peripherally inserted central venous catheters, 3 of 57 (5.3%); and arterial catheters, 7 of 142 (4.9%). There was no statistically significant difference between these type-specific contamination rates (P = 0.99 by binomial data analysis). The contaminating microorganisms isolated from catheter-drawn samples were more diverse (included 33 coagulase-negative staphylococci, 6 diphtheroids, 5 viridans group and nonhemolytic streptococci, 4 enterococci, Staphylococcus aureus isolates, and 1 isolate each of Micrococcus sp., Lactobacillus sp., Propionibacterium sp., Escherichia coli, Clostridium perfringens, Veillonella sp., Bacteroides sp., mixed gram-positive bacteria, and Candida sp.) than those isolated from venipuncture samples (included 21 coagulase-negative staphylococci, 2 isolates of Micrococcus sp., and 1 isolate each of Propionibacterium sp., Bacillus sp., Peptostreptococcus sp., and Clostridium septicum).

                              
View this table:
[in this window]
[in a new window]
 
TABLE 1.   Clinical significance of results of concurrent intravascular catheter-drawn and direct venipuncture blood cultures

Our data indicate that intravascular catheter-drawn blood cultures are more likely to be contaminated than direct venipuncture blood cultures. This comparison of the contamination rates by the two methods of blood collection is validated by concordance of the true-positive rates. However, the retrospective design of this study precluded standardization of collection technique and assurance of accurate labeling for all samples that may have been eligible for inclusion. Moreover, although the investigators were assiduous and experienced, their categorization of isolates was subjective and not blind, as are ultimately all clinical judgments. The comparison of contamination rates for individual intravascular catheter types is particularly problematic, because insertion technique for, use of, and care for the different catheter types were not standardized.

Several researchers previously have compared simultaneous catheter-drawn and direct venipuncture blood cultures to seek to answer the same question addressed in this study. All studies including preexisting intravascular catheters (1, 3, 4, 8, 9), including our study, have shown a higher rate of contamination for catheter-drawn samples; all studies including only newly inserted intravascular catheters (2, 5, 7) have shown no increase in contamination for catheter-drawn samples.

We do not believe that the increased risk of contamination contraindicates the use of intravascular catheters for blood culture collection, but our findings do support the recommendation to take a catheter-drawn sample only when direct venipuncture is not possible or safe. Moreover, if blood from a catheter after initial insertion is cultured, we recommend collecting a second and concurrent independent venipuncture sample to aid interpretation should contamination occur. Last and importantly, clinicians must be aware of the pitfalls in interpretation of positive cathether-drawn samples.


    ACKNOWLEDGMENTS

We thank David M. Higdon for help with statistical analysis.


    FOOTNOTES

* Corresponding author. Mailing address: Clinical Microbiology Laboratory, Box 3938, Duke University Medical Center, Durham, NC 27710. Phone: (919) 684-6474. Fax: (919) 684-8519. E-mail: relle001{at}mc.duke.edu.


    REFERENCES
Top
Abstract
Text
References

1. Bryant, J. K., and C. L. Strand. 1987. Reliability of blood cultures collected from intravascular catheter versus venipuncture. Am. J. Clin. Pathol. 88:113-116[Medline].
2. Cowett, R. M., G. Peter, D. O. Hakanson, and W. Oh. 1976. Reliability of bacterial culture of blood obtained from an umbilical artery catheter. J. Pediatr. 88:1035-1036[CrossRef][Medline].
3. DesJardin, J. A., M. A. Falagas, R. Ruthazer, J. Griffith, D. Wawrose, D. Schenkein, K. Miller, and D. R. Snydman. 1999. Clinical utility of blood cultures drawn from indwelling central venous catheters in hospitalised patients with cancer. Ann. Intern. Med. 131:641-647[Abstract/Free Full Text].
4. Felices, F. J., J. L. Hernandez, J. Ruiz, J. Meseguer, J. A. Gomez, and E. Molina. 1979. Use of the central venous pressure catheter to obtain blood cultures. Crit. Care Med. 7:78-79[Medline].
5. Isaacman, D. J., and R. B. Karasic. 1990. Utility of collecting blood cultures through newly inserted intravenous catheters. Pediatr. Infect. Dis. J. 9:815-818[Medline].
6. Mirrett, S., R. J. Everts, and L. B. Reller. 2001. Controlled comparison of original vented aerobic FAN medium with new nonvented Bact/ALERT FA medium for culturing blood. J. Clin. Microbiol. 39:2098-2101[Abstract/Free Full Text].
7. Pourcyrous, M., S. B. Korones, H. S. Bada, T. Patterson, and V. Baselski. 1988. Indwelling umbilical arterial catheter: a preferred sampling site for blood culture. Pediatrics 81:821-825[Abstract/Free Full Text].
8. Tafuro, P., D. Colbourn, I. Gurevich, P. Schoch, H. Wachs, S. Krystofiak, and B. A. Cunha. 1986. Comparison of blood cultures obtained simultaneously by venipuncture and from vascular lines. J. Hosp. Infect. 7:283-288[CrossRef][Medline].
9. Tonnesen, A., M. Peuler, and W. R. Lockwood. 1976. Cultures of blood drawn by catheters vs venipuncture. JAMA 235:1877[Abstract/Free Full Text].
10. Weinstein, M. P., M. L. Towns, S. M. Quartey, S. Mirrett, L. G. Reimer, G. Parmigiani, and L. B. Reller. 1997. The clinical significance of positive blood cultures in the 1990s: a prospective comprehensive evaluation of the microbiology, epidemiology, and outcome of bacteremia and fungemia in adults. Clin. Infect. Dis. 24:585-602.


Journal of Clinical Microbiology, September 2001, p. 3393-3394, Vol. 39, No. 9
0095-1137/01/$04.00+0   DOI: 10.1128/JCM.39.9.3393-3394.2001
Copyright © 2001, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Falagas, M. E., Kazantzi, M. S., Bliziotis, I. A. (2008). Comparison of utility of blood cultures from intravascular catheters and peripheral veins: a systematic review and decision analysis. J Med Microbiol 57: 1-8 [Abstract] [Full Text]  
  • Hall, K. K., Lyman, J. A. (2006). Updated Review of Blood Culture Contamination. Clin. Microbiol. Rev. 19: 788-802 [Abstract] [Full Text]  
  • Weinstein, M. P. (2003). Blood Culture Contamination: Persisting Problems and Partial Progress. J. Clin. Microbiol. 41: 2275-2278 [Full Text]  

This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Everts, R. J.
Right arrow Articles by Reller, L. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Everts, R. J.
Right arrow Articles by Reller, L. B.